ABAP Select data from SAP table CMIX into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP CMIX table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to CMIX. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the CMIX table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_CMIX TYPE STANDARD TABLE OF CMIX,
      WA_CMIX TYPE CMIX,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <CMIX> TYPE CMIX.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_CMIX.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM CMIX
  INTO TABLE IT_CMIX.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM CMIX
*  INTO TABLE @DATA(IT_CMIX2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_CMIX INDEX 1 INTO DATA(WA_CMIX2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_CMIX ASSIGNING <CMIX>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<CMIX>-MATNR = 1.
<CMIX>-VRKME = 1.
<CMIX>-EAN11 = 1.
<CMIX>-VKORG = 1.
<CMIX>-VTWEG = 1.
ENDLOOP.

LOOP AT IT_CMIX INTO WA_CMIX.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_CMIX-WERKS, sy-vline,
WA_CMIX-PLTYP, sy-vline,
WA_CMIX-BGINT, sy-vline,
WA_CMIX-KPOSN, sy-vline,
WA_CMIX-KPOSN_M, sy-vline,
WA_CMIX-MATNR_M, sy-vline.
ENDLOOP. *Add any further fields from structure WA_CMIX you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_CMIX TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_CMIX INTO WA_CMIX. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_CMIX-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CMIX-MATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field VRKME CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_CMIX-VRKME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CMIX-VRKME.
WRITE:/ 'New Value:', ld_input.

*Conversion exit EAN11, internal->external for field EAN11 CALL FUNCTION 'CONVERSION_EXIT_EAN11_OUTPUT' EXPORTING input = WA_CMIX-EAN11 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CMIX-EAN11.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field MATNR_M CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_CMIX-MATNR_M IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CMIX-MATNR_M.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field LIFNR_M CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CMIX-LIFNR_M IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CMIX-LIFNR_M.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field VRKME_M CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_CMIX-VRKME_M IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CMIX-VRKME_M.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MEINS_M CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_CMIX-MEINS_M IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CMIX-MEINS_M.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_CMIX_STR,
MATNR TYPE STRING,
VRKME TYPE STRING,
EAN11 TYPE STRING,
VKORG TYPE STRING,
VTWEG TYPE STRING,
WERKS TYPE STRING,
PLTYP TYPE STRING,
BGINT TYPE STRING,
KPOSN TYPE STRING,
KPOSN_M TYPE STRING,
MATNR_M TYPE STRING,
LIFNR_M TYPE STRING,
EKORG_M TYPE STRING,
EKABS_M TYPE STRING,
EKPGR_M TYPE STRING,
WAERS_M TYPE STRING,
EKPNN_M TYPE STRING,
KWAER_M TYPE STRING,
VRKPE_M TYPE STRING,
VRKME_M TYPE STRING,
MENGE_M TYPE STRING,
MEINS_M TYPE STRING,END OF T_EKKO_STR. DATA: WA_CMIX_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_CMIX_STR-MATNR sy-vline
WA_CMIX_STR-VRKME sy-vline
WA_CMIX_STR-EAN11 sy-vline
WA_CMIX_STR-VKORG sy-vline
WA_CMIX_STR-VTWEG sy-vline
WA_CMIX_STR-WERKS sy-vline
WA_CMIX_STR-PLTYP sy-vline
WA_CMIX_STR-BGINT sy-vline
WA_CMIX_STR-KPOSN sy-vline
WA_CMIX_STR-KPOSN_M sy-vline
WA_CMIX_STR-MATNR_M sy-vline
WA_CMIX_STR-LIFNR_M sy-vline
WA_CMIX_STR-EKORG_M sy-vline
WA_CMIX_STR-EKABS_M sy-vline
WA_CMIX_STR-EKPGR_M sy-vline
WA_CMIX_STR-WAERS_M sy-vline
WA_CMIX_STR-EKPNN_M sy-vline
WA_CMIX_STR-KWAER_M sy-vline
WA_CMIX_STR-VRKPE_M sy-vline
WA_CMIX_STR-VRKME_M sy-vline
WA_CMIX_STR-MENGE_M sy-vline
WA_CMIX_STR-MEINS_M sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.