ABAP Select data from SAP table CNSE_PRPS_INT into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP CNSE_PRPS_INT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to CNSE_PRPS_INT. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the CNSE_PRPS_INT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_CNSE_PRPS_INT TYPE STANDARD TABLE OF CNSE_PRPS_INT, WA_CNSE_PRPS_INT TYPE CNSE_PRPS_INT, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <CNSE_PRPS_INT> TYPE CNSE_PRPS_INT. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_CNSE_PRPS_INT. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM CNSE_PRPS_INT INTO TABLE IT_CNSE_PRPS_INT. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM CNSE_PRPS_INT * INTO TABLE @DATA(IT_CNSE_PRPS_INT2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_CNSE_PRPS_INT INDEX 1 INTO DATA(WA_CNSE_PRPS_INT2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_CNSE_PRPS_INT ASSIGNING <CNSE_PRPS_INT>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<CNSE_PRPS_INT>-POST1 = 1.
<CNSE_PRPS_INT>-PSPNR = 1.
<CNSE_PRPS_INT>-PSPID = 1.
<CNSE_PRPS_INT>-ERDAT = 1.
<CNSE_PRPS_INT>-AEDAT = 1.
ENDLOOP. LOOP AT IT_CNSE_PRPS_INT INTO WA_CNSE_PRPS_INT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_CNSE_PRPS_INT-VERNR, sy-vline,
WA_CNSE_PRPS_INT-ASTNR, sy-vline,
WA_CNSE_PRPS_INT-PBUKR, sy-vline,
WA_CNSE_PRPS_INT-PGSBR, sy-vline,
WA_CNSE_PRPS_INT-PKOKR, sy-vline,
WA_CNSE_PRPS_INT-PRCTR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_CNSE_PRPS_INT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_CNSE_PRPS_INT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_CNSE_PRPS_INT INTO WA_CNSE_PRPS_INT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ABPSP, internal->external for field PSPNR CALL FUNCTION 'CONVERSION_EXIT_ABPSP_OUTPUT' EXPORTING input = WA_CNSE_PRPS_INT-PSPNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CNSE_PRPS_INT-PSPNR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ABPSN, internal->external for field PSPID CALL FUNCTION 'CONVERSION_EXIT_ABPSN_OUTPUT' EXPORTING input = WA_CNSE_PRPS_INT-PSPID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CNSE_PRPS_INT-PSPID.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field PRCTR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CNSE_PRPS_INT-PRCTR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CNSE_PRPS_INT-PRCTR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field AKSTL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CNSE_PRPS_INT-AKSTL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CNSE_PRPS_INT-AKSTL.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field FKSTL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CNSE_PRPS_INT-FKSTL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CNSE_PRPS_INT-FKSTL.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field USE04 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_CNSE_PRPS_INT-USE04 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CNSE_PRPS_INT-USE04.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field USE05 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_CNSE_PRPS_INT-USE05 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CNSE_PRPS_INT-USE05.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ISOLA, internal->external for field TXTSP CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_CNSE_PRPS_INT-TXTSP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CNSE_PRPS_INT-TXTSP.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ABPSN, internal->external for field POSID CALL FUNCTION 'CONVERSION_EXIT_ABPSN_OUTPUT' EXPORTING input = WA_CNSE_PRPS_INT-POSID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CNSE_PRPS_INT-POSID.
WRITE:/ 'New Value:', ld_input.
*Conversion exit KONPD, internal->external for field PSPHI CALL FUNCTION 'CONVERSION_EXIT_KONPD_OUTPUT' EXPORTING input = WA_CNSE_PRPS_INT-PSPHI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CNSE_PRPS_INT-PSPHI.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_CNSE_PRPS_INT_STR,
POST1 TYPE STRING,
PSPNR TYPE STRING,
PSPID TYPE STRING,
ERDAT TYPE STRING,
AEDAT TYPE STRING,
VERNR TYPE STRING,
ASTNR TYPE STRING,
PBUKR TYPE STRING,
PGSBR TYPE STRING,
PKOKR TYPE STRING,
PRCTR TYPE STRING,
PRART TYPE STRING,
AKSTL TYPE STRING,
FKSTL TYPE STRING,
AKOKR TYPE STRING,
FKOKR TYPE STRING,
PSPRI TYPE STRING,
PWPOS TYPE STRING,
WERKS TYPE STRING,
STTXT_INT TYPE STRING,
STTXT_EXT TYPE STRING,
USR00 TYPE STRING,
USR01 TYPE STRING,
USR02 TYPE STRING,
USR03 TYPE STRING,
USR04 TYPE STRING,
USE04 TYPE STRING,
USR05 TYPE STRING,
USE05 TYPE STRING,
USR06 TYPE STRING,
USE06 TYPE STRING,
USR07 TYPE STRING,
USE07 TYPE STRING,
USR08 TYPE STRING,
USR09 TYPE STRING,
USR10 TYPE STRING,
USR11 TYPE STRING,
OBJNR TYPE STRING,
TXTSP TYPE STRING,
POSID TYPE STRING,
PSPHI TYPE STRING,END OF T_EKKO_STR. DATA: WA_CNSE_PRPS_INT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_CNSE_PRPS_INT_STR-POST1 sy-vline
WA_CNSE_PRPS_INT_STR-PSPNR sy-vline
WA_CNSE_PRPS_INT_STR-PSPID sy-vline
WA_CNSE_PRPS_INT_STR-ERDAT sy-vline
WA_CNSE_PRPS_INT_STR-AEDAT sy-vline
WA_CNSE_PRPS_INT_STR-VERNR sy-vline
WA_CNSE_PRPS_INT_STR-ASTNR sy-vline
WA_CNSE_PRPS_INT_STR-PBUKR sy-vline
WA_CNSE_PRPS_INT_STR-PGSBR sy-vline
WA_CNSE_PRPS_INT_STR-PKOKR sy-vline
WA_CNSE_PRPS_INT_STR-PRCTR sy-vline
WA_CNSE_PRPS_INT_STR-PRART sy-vline
WA_CNSE_PRPS_INT_STR-AKSTL sy-vline
WA_CNSE_PRPS_INT_STR-FKSTL sy-vline
WA_CNSE_PRPS_INT_STR-AKOKR sy-vline
WA_CNSE_PRPS_INT_STR-FKOKR sy-vline
WA_CNSE_PRPS_INT_STR-PSPRI sy-vline
WA_CNSE_PRPS_INT_STR-PWPOS sy-vline
WA_CNSE_PRPS_INT_STR-WERKS sy-vline
WA_CNSE_PRPS_INT_STR-STTXT_INT sy-vline
WA_CNSE_PRPS_INT_STR-STTXT_EXT sy-vline
WA_CNSE_PRPS_INT_STR-USR00 sy-vline
WA_CNSE_PRPS_INT_STR-USR01 sy-vline
WA_CNSE_PRPS_INT_STR-USR02 sy-vline
WA_CNSE_PRPS_INT_STR-USR03 sy-vline
WA_CNSE_PRPS_INT_STR-USR04 sy-vline
WA_CNSE_PRPS_INT_STR-USE04 sy-vline
WA_CNSE_PRPS_INT_STR-USR05 sy-vline
WA_CNSE_PRPS_INT_STR-USE05 sy-vline
WA_CNSE_PRPS_INT_STR-USR06 sy-vline
WA_CNSE_PRPS_INT_STR-USE06 sy-vline
WA_CNSE_PRPS_INT_STR-USR07 sy-vline
WA_CNSE_PRPS_INT_STR-USE07 sy-vline
WA_CNSE_PRPS_INT_STR-USR08 sy-vline
WA_CNSE_PRPS_INT_STR-USR09 sy-vline
WA_CNSE_PRPS_INT_STR-USR10 sy-vline
WA_CNSE_PRPS_INT_STR-USR11 sy-vline
WA_CNSE_PRPS_INT_STR-OBJNR sy-vline
WA_CNSE_PRPS_INT_STR-TXTSP sy-vline
WA_CNSE_PRPS_INT_STR-POSID sy-vline
WA_CNSE_PRPS_INT_STR-PSPHI sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.