ABAP Select data from SAP table CNV_10020_ASTATE into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP CNV_10020_ASTATE table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to CNV_10020_ASTATE. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the CNV_10020_ASTATE table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_CNV_10020_ASTATE TYPE STANDARD TABLE OF CNV_10020_ASTATE, WA_CNV_10020_ASTATE TYPE CNV_10020_ASTATE, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <CNV_10020_ASTATE> TYPE CNV_10020_ASTATE. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_CNV_10020_ASTATE. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM CNV_10020_ASTATE INTO TABLE IT_CNV_10020_ASTATE. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM CNV_10020_ASTATE * INTO TABLE @DATA(IT_CNV_10020_ASTATE2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_CNV_10020_ASTATE INDEX 1 INTO DATA(WA_CNV_10020_ASTATE2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_CNV_10020_ASTATE ASSIGNING <CNV_10020_ASTATE>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<CNV_10020_ASTATE>-MANDT = 1.
<CNV_10020_ASTATE>-PACKID = 1.
<CNV_10020_ASTATE>-TABNAME = 1.
<CNV_10020_ASTATE>-ANA_STATUS = 1.
<CNV_10020_ASTATE>-ANA_ACTIVITY = 1.
ENDLOOP. LOOP AT IT_CNV_10020_ASTATE INTO WA_CNV_10020_ASTATE. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_CNV_10020_ASTATE-RECORDS_OCLNT, sy-vline,
WA_CNV_10020_ASTATE-RECORDS_READ, sy-vline,
WA_CNV_10020_ASTATE-DURATION, sy-vline,
WA_CNV_10020_ASTATE-START_DATE, sy-vline,
WA_CNV_10020_ASTATE-START_TIME, sy-vline,
WA_CNV_10020_ASTATE-END_DATE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_CNV_10020_ASTATE you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_CNV_10020_ASTATE TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_CNV_10020_ASTATE INTO WA_CNV_10020_ASTATE. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit CNVO6, internal->external for field ANA_STATUS CALL FUNCTION 'CONVERSION_EXIT_CNVO6_OUTPUT' EXPORTING input = WA_CNV_10020_ASTATE-ANA_STATUS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CNV_10020_ASTATE-ANA_STATUS.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CNVO1, internal->external for field ANA_ACTIVITY CALL FUNCTION 'CONVERSION_EXIT_CNVO1_OUTPUT' EXPORTING input = WA_CNV_10020_ASTATE-ANA_ACTIVITY IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CNV_10020_ASTATE-ANA_ACTIVITY.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CNVO5, internal->external for field DURATION CALL FUNCTION 'CONVERSION_EXIT_CNVO5_OUTPUT' EXPORTING input = WA_CNV_10020_ASTATE-DURATION IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CNV_10020_ASTATE-DURATION.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_CNV_10020_ASTATE_STR,
MANDT TYPE STRING,
PACKID TYPE STRING,
TABNAME TYPE STRING,
ANA_STATUS TYPE STRING,
ANA_ACTIVITY TYPE STRING,
RECORDS_OCLNT TYPE STRING,
RECORDS_READ TYPE STRING,
DURATION TYPE STRING,
START_DATE TYPE STRING,
START_TIME TYPE STRING,
END_DATE TYPE STRING,
END_TIME TYPE STRING,
JOBNAME TYPE STRING,
JOBCOUNT TYPE STRING,
STARTTIME TYPE STRING,
ENDTIME TYPE STRING,END OF T_EKKO_STR. DATA: WA_CNV_10020_ASTATE_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_CNV_10020_ASTATE_STR-MANDT sy-vline
WA_CNV_10020_ASTATE_STR-PACKID sy-vline
WA_CNV_10020_ASTATE_STR-TABNAME sy-vline
WA_CNV_10020_ASTATE_STR-ANA_STATUS sy-vline
WA_CNV_10020_ASTATE_STR-ANA_ACTIVITY sy-vline
WA_CNV_10020_ASTATE_STR-RECORDS_OCLNT sy-vline
WA_CNV_10020_ASTATE_STR-RECORDS_READ sy-vline
WA_CNV_10020_ASTATE_STR-DURATION sy-vline
WA_CNV_10020_ASTATE_STR-START_DATE sy-vline
WA_CNV_10020_ASTATE_STR-START_TIME sy-vline
WA_CNV_10020_ASTATE_STR-END_DATE sy-vline
WA_CNV_10020_ASTATE_STR-END_TIME sy-vline
WA_CNV_10020_ASTATE_STR-JOBNAME sy-vline
WA_CNV_10020_ASTATE_STR-JOBCOUNT sy-vline
WA_CNV_10020_ASTATE_STR-STARTTIME sy-vline
WA_CNV_10020_ASTATE_STR-ENDTIME sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.