ABAP Select data from SAP table CNV_10940_SRCRST into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP CNV_10940_SRCRST table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to CNV_10940_SRCRST. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the CNV_10940_SRCRST table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_CNV_10940_SRCRST TYPE STANDARD TABLE OF CNV_10940_SRCRST, WA_CNV_10940_SRCRST TYPE CNV_10940_SRCRST, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <CNV_10940_SRCRST> TYPE CNV_10940_SRCRST. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_CNV_10940_SRCRST. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM CNV_10940_SRCRST INTO TABLE IT_CNV_10940_SRCRST. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM CNV_10940_SRCRST * INTO TABLE @DATA(IT_CNV_10940_SRCRST2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_CNV_10940_SRCRST INDEX 1 INTO DATA(WA_CNV_10940_SRCRST2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_CNV_10940_SRCRST ASSIGNING <CNV_10940_SRCRST>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<CNV_10940_SRCRST>-MANDT = 1.
<CNV_10940_SRCRST>-RUNID = 1.
<CNV_10940_SRCRST>-PCLPACKID = 1.
<CNV_10940_SRCRST>-DESCRIPTION = 1.
<CNV_10940_SRCRST>-FILE_UPLOAD_FLAG = 1.
ENDLOOP. LOOP AT IT_CNV_10940_SRCRST INTO WA_CNV_10940_SRCRST. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_CNV_10940_SRCRST-CNVRENAM_FLAG, sy-vline,
WA_CNV_10940_SRCRST-MANUALLY_FLAG, sy-vline,
WA_CNV_10940_SRCRST-COA_FLAG, sy-vline,
WA_CNV_10940_SRCRST-CCD_FLAG, sy-vline,
WA_CNV_10940_SRCRST-CCDD_FLAG, sy-vline,
WA_CNV_10940_SRCRST-EXCEL_FLAG, sy-vline.
ENDLOOP. *Add any further fields from structure WA_CNV_10940_SRCRST you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_CNV_10940_SRCRST TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_CNV_10940_SRCRST INTO WA_CNV_10940_SRCRST. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_CNV_10940_SRCRST_STR,
MANDT TYPE STRING,
RUNID TYPE STRING,
PCLPACKID TYPE STRING,
DESCRIPTION TYPE STRING,
FILE_UPLOAD_FLAG TYPE STRING,
CNVRENAM_FLAG TYPE STRING,
MANUALLY_FLAG TYPE STRING,
COA_FLAG TYPE STRING,
CCD_FLAG TYPE STRING,
CCDD_FLAG TYPE STRING,
EXCEL_FLAG TYPE STRING,
DOMAIN_FLAG TYPE STRING,
MAN_DOM_FLAG TYPE STRING,
STR_FLAG TYPE STRING,
WORD_FLAG TYPE STRING,
DISPLAY_FLAG TYPE STRING,
CONFIRM_FLAG TYPE STRING,
CONTENT_FORMAT TYPE STRING,END OF T_EKKO_STR. DATA: WA_CNV_10940_SRCRST_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_CNV_10940_SRCRST_STR-MANDT sy-vline
WA_CNV_10940_SRCRST_STR-RUNID sy-vline
WA_CNV_10940_SRCRST_STR-PCLPACKID sy-vline
WA_CNV_10940_SRCRST_STR-DESCRIPTION sy-vline
WA_CNV_10940_SRCRST_STR-FILE_UPLOAD_FLAG sy-vline
WA_CNV_10940_SRCRST_STR-CNVRENAM_FLAG sy-vline
WA_CNV_10940_SRCRST_STR-MANUALLY_FLAG sy-vline
WA_CNV_10940_SRCRST_STR-COA_FLAG sy-vline
WA_CNV_10940_SRCRST_STR-CCD_FLAG sy-vline
WA_CNV_10940_SRCRST_STR-CCDD_FLAG sy-vline
WA_CNV_10940_SRCRST_STR-EXCEL_FLAG sy-vline
WA_CNV_10940_SRCRST_STR-DOMAIN_FLAG sy-vline
WA_CNV_10940_SRCRST_STR-MAN_DOM_FLAG sy-vline
WA_CNV_10940_SRCRST_STR-STR_FLAG sy-vline
WA_CNV_10940_SRCRST_STR-WORD_FLAG sy-vline
WA_CNV_10940_SRCRST_STR-DISPLAY_FLAG sy-vline
WA_CNV_10940_SRCRST_STR-CONFIRM_FLAG sy-vline
WA_CNV_10940_SRCRST_STR-CONTENT_FORMAT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.