ABAP Select data from SAP table CNV_PE_S_S4_TL_PLMZ_UP into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP CNV_PE_S_S4_TL_PLMZ_UP table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to CNV_PE_S_S4_TL_PLMZ_UP. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the CNV_PE_S_S4_TL_PLMZ_UP table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_CNV_PE_S_S4_TL_PLMZ_UP TYPE STANDARD TABLE OF CNV_PE_S_S4_TL_PLMZ_UP, WA_CNV_PE_S_S4_TL_PLMZ_UP TYPE CNV_PE_S_S4_TL_PLMZ_UP, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <CNV_PE_S_S4_TL_PLMZ_UP> TYPE CNV_PE_S_S4_TL_PLMZ_UP. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_CNV_PE_S_S4_TL_PLMZ_UP. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM CNV_PE_S_S4_TL_PLMZ_UP INTO TABLE IT_CNV_PE_S_S4_TL_PLMZ_UP. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM CNV_PE_S_S4_TL_PLMZ_UP * INTO TABLE @DATA(IT_CNV_PE_S_S4_TL_PLMZ_UP2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_CNV_PE_S_S4_TL_PLMZ_UP INDEX 1 INTO DATA(WA_CNV_PE_S_S4_TL_PLMZ_UP2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_CNV_PE_S_S4_TL_PLMZ_UP ASSIGNING <CNV_PE_S_S4_TL_PLMZ_UP>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<CNV_PE_S_S4_TL_PLMZ_UP>-PLNTY = 1.
<CNV_PE_S_S4_TL_PLMZ_UP>-PLNNR = 1.
<CNV_PE_S_S4_TL_PLMZ_UP>-PLNAL = 1.
<CNV_PE_S_S4_TL_PLMZ_UP>-PLNKN = 1.
<CNV_PE_S_S4_TL_PLMZ_UP>-ZUONR = 1.
ENDLOOP. LOOP AT IT_CNV_PE_S_S4_TL_PLMZ_UP INTO WA_CNV_PE_S_S4_TL_PLMZ_UP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_CNV_PE_S_S4_TL_PLMZ_UP-VORNR, sy-vline,
WA_CNV_PE_S_S4_TL_PLMZ_UP-IDNRK, sy-vline,
WA_CNV_PE_S_S4_TL_PLMZ_UP-RGEKZ, sy-vline,
WA_CNV_PE_S_S4_TL_PLMZ_UP-DISP, sy-vline,
WA_CNV_PE_S_S4_TL_PLMZ_UP-MENGE, sy-vline,
WA_CNV_PE_S_S4_TL_PLMZ_UP-MEINS, sy-vline.
ENDLOOP. *Add any further fields from structure WA_CNV_PE_S_S4_TL_PLMZ_UP you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_CNV_PE_S_S4_TL_PLMZ_UP TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_CNV_PE_S_S4_TL_PLMZ_UP INTO WA_CNV_PE_S_S4_TL_PLMZ_UP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_CNV_PE_S_S4_TL_PLMZ_UP_STR,
PLNTY TYPE STRING,
PLNNR TYPE STRING,
PLNAL TYPE STRING,
PLNKN TYPE STRING,
ZUONR TYPE STRING,
VORNR TYPE STRING,
IDNRK TYPE STRING,
RGEKZ TYPE STRING,
DISP TYPE STRING,
MENGE TYPE STRING,
MEINS TYPE STRING,
STLTY TYPE STRING,
STLNR TYPE STRING,
STLAL TYPE STRING,
STLKN TYPE STRING,
ABLAD TYPE STRING,
WEMPF TYPE STRING,
AENNR TYPE STRING,
DATUV TYPE STRING,
LOEKZ TYPE STRING,END OF T_EKKO_STR. DATA: WA_CNV_PE_S_S4_TL_PLMZ_UP_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_CNV_PE_S_S4_TL_PLMZ_UP_STR-PLNTY sy-vline
WA_CNV_PE_S_S4_TL_PLMZ_UP_STR-PLNNR sy-vline
WA_CNV_PE_S_S4_TL_PLMZ_UP_STR-PLNAL sy-vline
WA_CNV_PE_S_S4_TL_PLMZ_UP_STR-PLNKN sy-vline
WA_CNV_PE_S_S4_TL_PLMZ_UP_STR-ZUONR sy-vline
WA_CNV_PE_S_S4_TL_PLMZ_UP_STR-VORNR sy-vline
WA_CNV_PE_S_S4_TL_PLMZ_UP_STR-IDNRK sy-vline
WA_CNV_PE_S_S4_TL_PLMZ_UP_STR-RGEKZ sy-vline
WA_CNV_PE_S_S4_TL_PLMZ_UP_STR-DISP sy-vline
WA_CNV_PE_S_S4_TL_PLMZ_UP_STR-MENGE sy-vline
WA_CNV_PE_S_S4_TL_PLMZ_UP_STR-MEINS sy-vline
WA_CNV_PE_S_S4_TL_PLMZ_UP_STR-STLTY sy-vline
WA_CNV_PE_S_S4_TL_PLMZ_UP_STR-STLNR sy-vline
WA_CNV_PE_S_S4_TL_PLMZ_UP_STR-STLAL sy-vline
WA_CNV_PE_S_S4_TL_PLMZ_UP_STR-STLKN sy-vline
WA_CNV_PE_S_S4_TL_PLMZ_UP_STR-ABLAD sy-vline
WA_CNV_PE_S_S4_TL_PLMZ_UP_STR-WEMPF sy-vline
WA_CNV_PE_S_S4_TL_PLMZ_UP_STR-AENNR sy-vline
WA_CNV_PE_S_S4_TL_PLMZ_UP_STR-DATUV sy-vline
WA_CNV_PE_S_S4_TL_PLMZ_UP_STR-LOEKZ sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.