ABAP Select data from SAP table CNVLTHCM_TABCOMP into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP CNVLTHCM_TABCOMP table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to CNVLTHCM_TABCOMP. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the CNVLTHCM_TABCOMP table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_CNVLTHCM_TABCOMP TYPE STANDARD TABLE OF CNVLTHCM_TABCOMP, WA_CNVLTHCM_TABCOMP TYPE CNVLTHCM_TABCOMP, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <CNVLTHCM_TABCOMP> TYPE CNVLTHCM_TABCOMP. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_CNVLTHCM_TABCOMP. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM CNVLTHCM_TABCOMP INTO TABLE IT_CNVLTHCM_TABCOMP. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM CNVLTHCM_TABCOMP * INTO TABLE @DATA(IT_CNVLTHCM_TABCOMP2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_CNVLTHCM_TABCOMP INDEX 1 INTO DATA(WA_CNVLTHCM_TABCOMP2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_CNVLTHCM_TABCOMP ASSIGNING <CNVLTHCM_TABCOMP>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<CNVLTHCM_TABCOMP>-MANDT = 1.
<CNVLTHCM_TABCOMP>-PACKID = 1.
<CNVLTHCM_TABCOMP>-CONVOBJECT = 1.
<CNVLTHCM_TABCOMP>-DEVCLASS = 1.
<CNVLTHCM_TABCOMP>-COMPONENT = 1.
ENDLOOP. LOOP AT IT_CNVLTHCM_TABCOMP INTO WA_CNVLTHCM_TABCOMP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_CNVLTHCM_TABCOMP-COMPONENT_ID, sy-vline,
WA_CNVLTHCM_TABCOMP-NO_EXIST, sy-vline,
WA_CNVLTHCM_TABCOMP-CLIDEP, sy-vline,
WA_CNVLTHCM_TABCOMP-CONTFLAG, sy-vline,
ENDLOOP. *Add any further fields from structure WA_CNVLTHCM_TABCOMP you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_CNVLTHCM_TABCOMP TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_CNVLTHCM_TABCOMP INTO WA_CNVLTHCM_TABCOMP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_CNVLTHCM_TABCOMP_STR,
MANDT TYPE STRING,
PACKID TYPE STRING,
CONVOBJECT TYPE STRING,
DEVCLASS TYPE STRING,
COMPONENT TYPE STRING,
COMPONENT_ID TYPE STRING,
NO_EXIST TYPE STRING,
CLIDEP TYPE STRING,
CONTFLAG TYPE STRING,END OF T_EKKO_STR. DATA: WA_CNVLTHCM_TABCOMP_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_CNVLTHCM_TABCOMP_STR-MANDT sy-vline
WA_CNVLTHCM_TABCOMP_STR-PACKID sy-vline
WA_CNVLTHCM_TABCOMP_STR-CONVOBJECT sy-vline
WA_CNVLTHCM_TABCOMP_STR-DEVCLASS sy-vline
WA_CNVLTHCM_TABCOMP_STR-COMPONENT sy-vline
WA_CNVLTHCM_TABCOMP_STR-COMPONENT_ID sy-vline
WA_CNVLTHCM_TABCOMP_STR-NO_EXIST sy-vline
WA_CNVLTHCM_TABCOMP_STR-CLIDEP sy-vline
WA_CNVLTHCM_TABCOMP_STR-CONTFLAG sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.