ABAP Select data from SAP table CNVTDMS_09_CLU into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP CNVTDMS_09_CLU table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to CNVTDMS_09_CLU. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the CNVTDMS_09_CLU table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_CNVTDMS_09_CLU TYPE STANDARD TABLE OF CNVTDMS_09_CLU, WA_CNVTDMS_09_CLU TYPE CNVTDMS_09_CLU, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <CNVTDMS_09_CLU> TYPE CNVTDMS_09_CLU. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_CNVTDMS_09_CLU. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM CNVTDMS_09_CLU INTO TABLE IT_CNVTDMS_09_CLU. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM CNVTDMS_09_CLU * INTO TABLE @DATA(IT_CNVTDMS_09_CLU2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_CNVTDMS_09_CLU INDEX 1 INTO DATA(WA_CNVTDMS_09_CLU2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_CNVTDMS_09_CLU ASSIGNING <CNVTDMS_09_CLU>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<CNVTDMS_09_CLU>-TABID = 1.
<CNVTDMS_09_CLU>-TASKID = 1.
<CNVTDMS_09_CLU>-CLUID_MIN = 1.
<CNVTDMS_09_CLU>-CLUID_MAX = 1.
<CNVTDMS_09_CLU>-RECREAD = 1.
ENDLOOP. LOOP AT IT_CNVTDMS_09_CLU INTO WA_CNVTDMS_09_CLU. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_CNVTDMS_09_CLU-RECUPD, sy-vline,
WA_CNVTDMS_09_CLU-CLUBY, sy-vline,
WA_CNVTDMS_09_CLU-COMBY, sy-vline,
WA_CNVTDMS_09_CLU-STATE_LOG, sy-vline,
WA_CNVTDMS_09_CLU-STATE_TEC, sy-vline,
WA_CNVTDMS_09_CLU-TASKID_MAX, sy-vline.
ENDLOOP. *Add any further fields from structure WA_CNVTDMS_09_CLU you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_CNVTDMS_09_CLU TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_CNVTDMS_09_CLU INTO WA_CNVTDMS_09_CLU. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_CNVTDMS_09_CLU_STR,
TABID TYPE STRING,
TASKID TYPE STRING,
CLUID_MIN TYPE STRING,
CLUID_MAX TYPE STRING,
RECREAD TYPE STRING,
RECUPD TYPE STRING,
CLUBY TYPE STRING,
COMBY TYPE STRING,
STATE_LOG TYPE STRING,
STATE_TEC TYPE STRING,
TASKID_MAX TYPE STRING,
PARCLU_MIN TYPE STRING,
CLUDEL TYPE STRING,END OF T_EKKO_STR. DATA: WA_CNVTDMS_09_CLU_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_CNVTDMS_09_CLU_STR-TABID sy-vline
WA_CNVTDMS_09_CLU_STR-TASKID sy-vline
WA_CNVTDMS_09_CLU_STR-CLUID_MIN sy-vline
WA_CNVTDMS_09_CLU_STR-CLUID_MAX sy-vline
WA_CNVTDMS_09_CLU_STR-RECREAD sy-vline
WA_CNVTDMS_09_CLU_STR-RECUPD sy-vline
WA_CNVTDMS_09_CLU_STR-CLUBY sy-vline
WA_CNVTDMS_09_CLU_STR-COMBY sy-vline
WA_CNVTDMS_09_CLU_STR-STATE_LOG sy-vline
WA_CNVTDMS_09_CLU_STR-STATE_TEC sy-vline
WA_CNVTDMS_09_CLU_STR-TASKID_MAX sy-vline
WA_CNVTDMS_09_CLU_STR-PARCLU_MIN sy-vline
WA_CNVTDMS_09_CLU_STR-CLUDEL sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.