ABAP Select data from SAP table COMC_SETTYPE_STR into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP COMC_SETTYPE_STR table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to COMC_SETTYPE_STR. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the COMC_SETTYPE_STR table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_COMC_SETTYPE_STR TYPE STANDARD TABLE OF COMC_SETTYPE_STR,
      WA_COMC_SETTYPE_STR TYPE COMC_SETTYPE_STR,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <COMC_SETTYPE_STR> TYPE COMC_SETTYPE_STR.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_COMC_SETTYPE_STR.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM COMC_SETTYPE_STR
  INTO TABLE IT_COMC_SETTYPE_STR.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM COMC_SETTYPE_STR
*  INTO TABLE @DATA(IT_COMC_SETTYPE_STR2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_COMC_SETTYPE_STR INDEX 1 INTO DATA(WA_COMC_SETTYPE_STR2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_COMC_SETTYPE_STR ASSIGNING <COMC_SETTYPE_STR>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<COMC_SETTYPE_STR>-SETTYPE_ID = 1.
<COMC_SETTYPE_STR>-SETTYPE_TABLE = 1.
<COMC_SETTYPE_STR>-SETTYPE_HTAB = 1.
<COMC_SETTYPE_STR>-SORTED_TABLE = 1.
<COMC_SETTYPE_STR>-MAINTAIN_TABLE = 1.
ENDLOOP.

LOOP AT IT_COMC_SETTYPE_STR INTO WA_COMC_SETTYPE_STR.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_COMC_SETTYPE_STR-MAINTAIN, sy-vline,
WA_COMC_SETTYPE_STR-MULTI_VALUE, sy-vline,
WA_COMC_SETTYPE_STR-UPDATE_CHECK, sy-vline,
WA_COMC_SETTYPE_STR-UI_SINGE_VALUE, sy-vline,
WA_COMC_SETTYPE_STR-UI_MULTI_VALUE, sy-vline,
WA_COMC_SETTYPE_STR-VIEW_NAME_CURR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_COMC_SETTYPE_STR you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_COMC_SETTYPE_STR TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_COMC_SETTYPE_STR INTO WA_COMC_SETTYPE_STR. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_COMC_SETTYPE_STR_STR,
SETTYPE_ID TYPE STRING,
SETTYPE_TABLE TYPE STRING,
SETTYPE_HTAB TYPE STRING,
SORTED_TABLE TYPE STRING,
MAINTAIN_TABLE TYPE STRING,
MAINTAIN TYPE STRING,
MULTI_VALUE TYPE STRING,
UPDATE_CHECK TYPE STRING,
UI_SINGE_VALUE TYPE STRING,
UI_MULTI_VALUE TYPE STRING,
VIEW_NAME_CURR TYPE STRING,
VIEW_NAME_HIST TYPE STRING,
SORTED_MV_TABLE TYPE STRING,
SETTYPE_DBTAB TYPE STRING,
SETTYPE_DBTABH TYPE STRING,
MULTI_VALUE_HTAB TYPE STRING,
MR_DATA TYPE STRING,
MR_DATA_TAB TYPE STRING,
UI_MAINT TYPE STRING,
UI_MAINT_TAB TYPE STRING,END OF T_EKKO_STR. DATA: WA_COMC_SETTYPE_STR_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_COMC_SETTYPE_STR_STR-SETTYPE_ID sy-vline
WA_COMC_SETTYPE_STR_STR-SETTYPE_TABLE sy-vline
WA_COMC_SETTYPE_STR_STR-SETTYPE_HTAB sy-vline
WA_COMC_SETTYPE_STR_STR-SORTED_TABLE sy-vline
WA_COMC_SETTYPE_STR_STR-MAINTAIN_TABLE sy-vline
WA_COMC_SETTYPE_STR_STR-MAINTAIN sy-vline
WA_COMC_SETTYPE_STR_STR-MULTI_VALUE sy-vline
WA_COMC_SETTYPE_STR_STR-UPDATE_CHECK sy-vline
WA_COMC_SETTYPE_STR_STR-UI_SINGE_VALUE sy-vline
WA_COMC_SETTYPE_STR_STR-UI_MULTI_VALUE sy-vline
WA_COMC_SETTYPE_STR_STR-VIEW_NAME_CURR sy-vline
WA_COMC_SETTYPE_STR_STR-VIEW_NAME_HIST sy-vline
WA_COMC_SETTYPE_STR_STR-SORTED_MV_TABLE sy-vline
WA_COMC_SETTYPE_STR_STR-SETTYPE_DBTAB sy-vline
WA_COMC_SETTYPE_STR_STR-SETTYPE_DBTABH sy-vline
WA_COMC_SETTYPE_STR_STR-MULTI_VALUE_HTAB sy-vline
WA_COMC_SETTYPE_STR_STR-MR_DATA sy-vline
WA_COMC_SETTYPE_STR_STR-MR_DATA_TAB sy-vline
WA_COMC_SETTYPE_STR_STR-UI_MAINT sy-vline
WA_COMC_SETTYPE_STR_STR-UI_MAINT_TAB sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.