ABAP Select data from SAP table CPHYSINVSITN into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP CPHYSINVSITN table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to CPHYSINVSITN. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the CPHYSINVSITN table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_CPHYSINVSITN TYPE STANDARD TABLE OF CPHYSINVSITN, WA_CPHYSINVSITN TYPE CPHYSINVSITN, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <CPHYSINVSITN> TYPE CPHYSINVSITN. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_CPHYSINVSITN. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM CPHYSINVSITN INTO TABLE IT_CPHYSINVSITN. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM CPHYSINVSITN * INTO TABLE @DATA(IT_CPHYSINVSITN2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_CPHYSINVSITN INDEX 1 INTO DATA(WA_CPHYSINVSITN2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_CPHYSINVSITN ASSIGNING <CPHYSINVSITN>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<CPHYSINVSITN>-MANDT = 1.
<CPHYSINVSITN>-PHYSINVTRYSITNID = 1.
<CPHYSINVSITN>-FISCALYEAR = 1.
<CPHYSINVSITN>-PHYSICALINVENTORYDOCUMENT = 1.
<CPHYSINVSITN>-PHYSICALINVENTORYDOCUMENTITEM = 1.
ENDLOOP. LOOP AT IT_CPHYSINVSITN INTO WA_CPHYSINVSITN. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_CPHYSINVSITN-MATERIAL, sy-vline,
WA_CPHYSINVSITN-PLANT, sy-vline,
WA_CPHYSINVSITN-STORAGELOCATION, sy-vline,
WA_CPHYSINVSITN-WAREHOUSESTORAGEBIN, sy-vline,
WA_CPHYSINVSITN-BATCH, sy-vline,
WA_CPHYSINVSITN-INVENTORYSPECIALSTOCKTYPE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_CPHYSINVSITN you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_CPHYSINVSITN TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_CPHYSINVSITN INTO WA_CPHYSINVSITN. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit GJAHR, internal->external for field FISCALYEAR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_CPHYSINVSITN-FISCALYEAR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CPHYSINVSITN-FISCALYEAR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field PHYSICALINVENTORYDOCUMENT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CPHYSINVSITN-PHYSICALINVENTORYDOCUMENT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CPHYSINVSITN-PHYSICALINVENTORYDOCUMENT.
WRITE:/ 'New Value:', ld_input.
*Conversion exit MATN1, internal->external for field MATERIAL CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_CPHYSINVSITN-MATERIAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CPHYSINVSITN-MATERIAL.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field SALESORDER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CPHYSINVSITN-SALESORDER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CPHYSINVSITN-SALESORDER.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field SUPPLIER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CPHYSINVSITN-SUPPLIER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CPHYSINVSITN-SUPPLIER.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field STOCKOWNER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CPHYSINVSITN-STOCKOWNER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CPHYSINVSITN-STOCKOWNER.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field CUSTOMER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CPHYSINVSITN-CUSTOMER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CPHYSINVSITN-CUSTOMER.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ABPSN, internal->external for field WBSELEMENT CALL FUNCTION 'CONVERSION_EXIT_ABPSN_OUTPUT' EXPORTING input = WA_CPHYSINVSITN-WBSELEMENT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CPHYSINVSITN-WBSELEMENT.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field MATERIALBASEUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_CPHYSINVSITN-MATERIALBASEUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CPHYSINVSITN-MATERIALBASEUNIT.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field UNITOFENTRY CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_CPHYSINVSITN-UNITOFENTRY IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CPHYSINVSITN-UNITOFENTRY.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field MATERIALDOCUMENT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CPHYSINVSITN-MATERIALDOCUMENT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CPHYSINVSITN-MATERIALDOCUMENT.
WRITE:/ 'New Value:', ld_input.
*Conversion exit GJAHR, internal->external for field MATERIALDOCUMENTYEAR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_CPHYSINVSITN-MATERIALDOCUMENTYEAR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CPHYSINVSITN-MATERIALDOCUMENTYEAR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit MATN1, internal->external for field CROSSPLANTCONFIGURABLEMATERIAL CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_CPHYSINVSITN-CROSSPLANTCONFIGURABLEMATERIAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CPHYSINVSITN-CROSSPLANTCONFIGURABLEMATERIAL.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_CPHYSINVSITN_STR,
MANDT TYPE STRING,
PHYSINVTRYSITNID TYPE STRING,
FISCALYEAR TYPE STRING,
PHYSICALINVENTORYDOCUMENT TYPE STRING,
PHYSICALINVENTORYDOCUMENTITEM TYPE STRING,
MATERIAL TYPE STRING,
PLANT TYPE STRING,
STORAGELOCATION TYPE STRING,
WAREHOUSESTORAGEBIN TYPE STRING,
BATCH TYPE STRING,
INVENTORYSPECIALSTOCKTYPE TYPE STRING,
GOODSMOVEMENTTYPE TYPE STRING,
PHYSICALINVENTORYSTOCKTYPE TYPE STRING,
SALESORDER TYPE STRING,
SALESORDERITEM TYPE STRING,
SCHEDULELINE TYPE STRING,
SUPPLIER TYPE STRING,
STOCKOWNER TYPE STRING,
CUSTOMER TYPE STRING,
WBSELEMENT TYPE STRING,
PRODUCTCATEGORY TYPE STRING,
LASTCHANGEDATE TYPE STRING,
PHYSICALINVENTORYLASTCOUNTDATE TYPE STRING,
POSTINGDATE TYPE STRING,
PHYSINVENTORYPLANNEDCOUNTDATE TYPE STRING,
ISHANDLEDINALTVUNITOFMSR TYPE STRING,
PHYSICALINVENTORYITEMISZERO TYPE STRING,
PHYSINVTRYITEMISDELETED TYPE STRING,
QUANTITYINUNITOFENTRY TYPE STRING,
QUANTITY TYPE STRING,
BOOKQTYBFRCOUNTINMATLBASEUNIT TYPE STRING,
DIFFERENCEQUANTITYINBASEUNIT TYPE STRING,
PHYSINVTRYDIFFERENCEINPERCENT TYPE STRING,
MATERIALBASEUNIT TYPE STRING,
UNITOFENTRY TYPE STRING,
CURRENCY TYPE STRING,
SLSPRICEAMOUNTINCOCODECRCY TYPE STRING,
PHYSINVTRYCTAMTINCOCODECRCY TYPE STRING,
BOOKQTYAMOUNTINCOCODECRCY TYPE STRING,
DIFFERENCEAMOUNTINCOCODECRCY TYPE STRING,
DIFFCOUNTEDBOOKAMTINCOCODECRY TYPE STRING,
ENTEREDSLSAMTINCOCODECRCY TYPE STRING,
ISVALUEONLYMATERIAL TYPE STRING,
MATERIALDOCUMENT TYPE STRING,
MATERIALDOCUMENTYEAR TYPE STRING,
MATERIALDOCUMENTITEM TYPE STRING,
CYCLECOUNTTYPE TYPE STRING,
NMBROFPHYSINVTRYPERFISCALYEAR TYPE STRING,
PHYSINVTRYINTVLFORCYCCOUNTING TYPE STRING,
PHYSINVTRYFLOATTIMECYCCOUNTING TYPE STRING,
REASONFORPHYSINVTRYDIFFERENCE TYPE STRING,
CROSSPLANTCONFIGURABLEMATERIAL TYPE STRING,
PHYSINVTRYDIFFISDISTRIBUTED TYPE STRING,
PHYSICALINVENTORYITEMISCOUNTED TYPE STRING,
PHYSINVTRYDIFFERENCEISPOSTED TYPE STRING,
PHYSINVTRYITEMISRECOUNTED TYPE STRING,
PHYSINVTRYISCREATEDBYRECOUNT TYPE STRING,
PHYSICALINVENTORYNUMBER TYPE STRING,
PHYSINVTRYDOCHASQTYSNAPSHOT TYPE STRING,
SALESPRICEVALUATIONISACTIVE TYPE STRING,
SERIALNUMBERPROFILE TYPE STRING,
PRODUCTTYPE TYPE STRING,
PRODUCTGROUP TYPE STRING,
SERIALIDENTIFIERASSGMTPROFILE TYPE STRING,
ISMARKEDFORDELETION TYPE STRING,
NUMBEROFPHYSINVENTORYCOUNTS TYPE STRING,
NUMBEROFPINVADJUSTMENTSPERYEAR TYPE STRING,
PINVDIFFQTYPERYEARINBASEUNIT TYPE STRING,
NMBROFDAYSSINCELASTPINVCOUNT TYPE STRING,
PHYSINVTRYITEMISNEVERCOUNTED TYPE STRING,
NROFGDSRCPTSINCELASTPINVCOUNT TYPE STRING,
GDSRCPTQTYSINCELASTCTINBSUNT TYPE STRING,
AVGSTKQTYSINCELASTCOUNTINBSUNT TYPE STRING,
INVTRYTURNOVERSINCELASTCNT TYPE STRING,
NROFGOODSISSSINCELASTPINVCOUNT TYPE STRING,
GDSISSQTYSINCELASTCOUNTINBSUNT TYPE STRING,END OF T_EKKO_STR. DATA: WA_CPHYSINVSITN_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_CPHYSINVSITN_STR-MANDT sy-vline
WA_CPHYSINVSITN_STR-PHYSINVTRYSITNID sy-vline
WA_CPHYSINVSITN_STR-FISCALYEAR sy-vline
WA_CPHYSINVSITN_STR-PHYSICALINVENTORYDOCUMENT sy-vline
WA_CPHYSINVSITN_STR-PHYSICALINVENTORYDOCUMENTITEM sy-vline
WA_CPHYSINVSITN_STR-MATERIAL sy-vline
WA_CPHYSINVSITN_STR-PLANT sy-vline
WA_CPHYSINVSITN_STR-STORAGELOCATION sy-vline
WA_CPHYSINVSITN_STR-WAREHOUSESTORAGEBIN sy-vline
WA_CPHYSINVSITN_STR-BATCH sy-vline
WA_CPHYSINVSITN_STR-INVENTORYSPECIALSTOCKTYPE sy-vline
WA_CPHYSINVSITN_STR-GOODSMOVEMENTTYPE sy-vline
WA_CPHYSINVSITN_STR-PHYSICALINVENTORYSTOCKTYPE sy-vline
WA_CPHYSINVSITN_STR-SALESORDER sy-vline
WA_CPHYSINVSITN_STR-SALESORDERITEM sy-vline
WA_CPHYSINVSITN_STR-SCHEDULELINE sy-vline
WA_CPHYSINVSITN_STR-SUPPLIER sy-vline
WA_CPHYSINVSITN_STR-STOCKOWNER sy-vline
WA_CPHYSINVSITN_STR-CUSTOMER sy-vline
WA_CPHYSINVSITN_STR-WBSELEMENT sy-vline
WA_CPHYSINVSITN_STR-PRODUCTCATEGORY sy-vline
WA_CPHYSINVSITN_STR-LASTCHANGEDATE sy-vline
WA_CPHYSINVSITN_STR-PHYSICALINVENTORYLASTCOUNTDATE sy-vline
WA_CPHYSINVSITN_STR-POSTINGDATE sy-vline
WA_CPHYSINVSITN_STR-PHYSINVENTORYPLANNEDCOUNTDATE sy-vline
WA_CPHYSINVSITN_STR-ISHANDLEDINALTVUNITOFMSR sy-vline
WA_CPHYSINVSITN_STR-PHYSICALINVENTORYITEMISZERO sy-vline
WA_CPHYSINVSITN_STR-PHYSINVTRYITEMISDELETED sy-vline
WA_CPHYSINVSITN_STR-QUANTITYINUNITOFENTRY sy-vline
WA_CPHYSINVSITN_STR-QUANTITY sy-vline
WA_CPHYSINVSITN_STR-BOOKQTYBFRCOUNTINMATLBASEUNIT sy-vline
WA_CPHYSINVSITN_STR-DIFFERENCEQUANTITYINBASEUNIT sy-vline
WA_CPHYSINVSITN_STR-PHYSINVTRYDIFFERENCEINPERCENT sy-vline
WA_CPHYSINVSITN_STR-MATERIALBASEUNIT sy-vline
WA_CPHYSINVSITN_STR-UNITOFENTRY sy-vline
WA_CPHYSINVSITN_STR-CURRENCY sy-vline
WA_CPHYSINVSITN_STR-SLSPRICEAMOUNTINCOCODECRCY sy-vline
WA_CPHYSINVSITN_STR-PHYSINVTRYCTAMTINCOCODECRCY sy-vline
WA_CPHYSINVSITN_STR-BOOKQTYAMOUNTINCOCODECRCY sy-vline
WA_CPHYSINVSITN_STR-DIFFERENCEAMOUNTINCOCODECRCY sy-vline
WA_CPHYSINVSITN_STR-DIFFCOUNTEDBOOKAMTINCOCODECRY sy-vline
WA_CPHYSINVSITN_STR-ENTEREDSLSAMTINCOCODECRCY sy-vline
WA_CPHYSINVSITN_STR-ISVALUEONLYMATERIAL sy-vline
WA_CPHYSINVSITN_STR-MATERIALDOCUMENT sy-vline
WA_CPHYSINVSITN_STR-MATERIALDOCUMENTYEAR sy-vline
WA_CPHYSINVSITN_STR-MATERIALDOCUMENTITEM sy-vline
WA_CPHYSINVSITN_STR-CYCLECOUNTTYPE sy-vline
WA_CPHYSINVSITN_STR-NMBROFPHYSINVTRYPERFISCALYEAR sy-vline
WA_CPHYSINVSITN_STR-PHYSINVTRYINTVLFORCYCCOUNTING sy-vline
WA_CPHYSINVSITN_STR-PHYSINVTRYFLOATTIMECYCCOUNTING sy-vline
WA_CPHYSINVSITN_STR-REASONFORPHYSINVTRYDIFFERENCE sy-vline
WA_CPHYSINVSITN_STR-CROSSPLANTCONFIGURABLEMATERIAL sy-vline
WA_CPHYSINVSITN_STR-PHYSINVTRYDIFFISDISTRIBUTED sy-vline
WA_CPHYSINVSITN_STR-PHYSICALINVENTORYITEMISCOUNTED sy-vline
WA_CPHYSINVSITN_STR-PHYSINVTRYDIFFERENCEISPOSTED sy-vline
WA_CPHYSINVSITN_STR-PHYSINVTRYITEMISRECOUNTED sy-vline
WA_CPHYSINVSITN_STR-PHYSINVTRYISCREATEDBYRECOUNT sy-vline
WA_CPHYSINVSITN_STR-PHYSICALINVENTORYNUMBER sy-vline
WA_CPHYSINVSITN_STR-PHYSINVTRYDOCHASQTYSNAPSHOT sy-vline
WA_CPHYSINVSITN_STR-SALESPRICEVALUATIONISACTIVE sy-vline
WA_CPHYSINVSITN_STR-SERIALNUMBERPROFILE sy-vline
WA_CPHYSINVSITN_STR-PRODUCTTYPE sy-vline
WA_CPHYSINVSITN_STR-PRODUCTGROUP sy-vline
WA_CPHYSINVSITN_STR-SERIALIDENTIFIERASSGMTPROFILE sy-vline
WA_CPHYSINVSITN_STR-ISMARKEDFORDELETION sy-vline
WA_CPHYSINVSITN_STR-NUMBEROFPHYSINVENTORYCOUNTS sy-vline
WA_CPHYSINVSITN_STR-NUMBEROFPINVADJUSTMENTSPERYEAR sy-vline
WA_CPHYSINVSITN_STR-PINVDIFFQTYPERYEARINBASEUNIT sy-vline
WA_CPHYSINVSITN_STR-NMBROFDAYSSINCELASTPINVCOUNT sy-vline
WA_CPHYSINVSITN_STR-PHYSINVTRYITEMISNEVERCOUNTED sy-vline
WA_CPHYSINVSITN_STR-NROFGDSRCPTSINCELASTPINVCOUNT sy-vline
WA_CPHYSINVSITN_STR-GDSRCPTQTYSINCELASTCTINBSUNT sy-vline
WA_CPHYSINVSITN_STR-AVGSTKQTYSINCELASTCOUNTINBSUNT sy-vline
WA_CPHYSINVSITN_STR-INVTRYTURNOVERSINCELASTCNT sy-vline
WA_CPHYSINVSITN_STR-NROFGOODSISSSINCELASTPINVCOUNT sy-vline
WA_CPHYSINVSITN_STR-GDSISSQTYSINCELASTCOUNTINBSUNT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.