ABAP Select data from SAP table CQMCHARESULTINFO into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP CQMCHARESULTINFO table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to CQMCHARESULTINFO. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the CQMCHARESULTINFO table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_CQMCHARESULTINFO TYPE STANDARD TABLE OF CQMCHARESULTINFO, WA_CQMCHARESULTINFO TYPE CQMCHARESULTINFO, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <CQMCHARESULTINFO> TYPE CQMCHARESULTINFO. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_CQMCHARESULTINFO. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM CQMCHARESULTINFO INTO TABLE IT_CQMCHARESULTINFO. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM CQMCHARESULTINFO * INTO TABLE @DATA(IT_CQMCHARESULTINFO2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_CQMCHARESULTINFO INDEX 1 INTO DATA(WA_CQMCHARESULTINFO2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_CQMCHARESULTINFO ASSIGNING <CQMCHARESULTINFO>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<CQMCHARESULTINFO>-MANDT = 1.
<CQMCHARESULTINFO>-INSPECTIONLOT = 1.
<CQMCHARESULTINFO>-INSPPLANOPERATIONINTERNALID = 1.
<CQMCHARESULTINFO>-INSPECTIONSUBSETINTERNALID = 1.
<CQMCHARESULTINFO>-INSPECTIONCHARACTERISTIC = 1.
ENDLOOP. LOOP AT IT_CQMCHARESULTINFO INTO WA_CQMCHARESULTINFO. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_CQMCHARESULTINFO-INSPRESULTITEMINTERNALID, sy-vline,
WA_CQMCHARESULTINFO-INSPECTIONMETHOD, sy-vline,
WA_CQMCHARESULTINFO-INSPECTIONSPECIFICATION, sy-vline,
WA_CQMCHARESULTINFO-INSPECTIONMETHODVERSION, sy-vline,
WA_CQMCHARESULTINFO-PLANT, sy-vline,
WA_CQMCHARESULTINFO-CHARACTERISTICATTRIBUTECATALOG, sy-vline.
ENDLOOP. *Add any further fields from structure WA_CQMCHARESULTINFO you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_CQMCHARESULTINFO TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_CQMCHARESULTINFO INTO WA_CQMCHARESULTINFO. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ALPHA, internal->external for field INSPECTIONLOT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CQMCHARESULTINFO-INSPECTIONLOT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CQMCHARESULTINFO-INSPECTIONLOT.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field INSPECTIONMETHOD CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CQMCHARESULTINFO-INSPECTIONMETHOD IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CQMCHARESULTINFO-INSPECTIONMETHOD.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field INSPECTIONSPECIFICATION CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CQMCHARESULTINFO-INSPECTIONSPECIFICATION IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CQMCHARESULTINFO-INSPECTIONSPECIFICATION.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field INSPECTIONMETHODVERSION CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CQMCHARESULTINFO-INSPECTIONMETHODVERSION IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CQMCHARESULTINFO-INSPECTIONMETHODVERSION.
WRITE:/ 'New Value:', ld_input.
*Conversion exit NUMCV, internal->external for field INSPECTIONOPERATION CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_CQMCHARESULTINFO-INSPECTIONOPERATION IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CQMCHARESULTINFO-INSPECTIONOPERATION.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field INSPECTIONSPECIFICATIONUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_CQMCHARESULTINFO-INSPECTIONSPECIFICATIONUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CQMCHARESULTINFO-INSPECTIONSPECIFICATIONUNIT.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field INSPRSLTFREEDEFINEDTESTEQUIP CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CQMCHARESULTINFO-INSPRSLTFREEDEFINEDTESTEQUIP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CQMCHARESULTINFO-INSPRSLTFREEDEFINEDTESTEQUIP.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field INSPECTIONRESULTITEM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CQMCHARESULTINFO-INSPECTIONRESULTITEM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CQMCHARESULTINFO-INSPECTIONRESULTITEM.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_CQMCHARESULTINFO_STR,
MANDT TYPE STRING,
INSPECTIONLOT TYPE STRING,
INSPPLANOPERATIONINTERNALID TYPE STRING,
INSPECTIONSUBSETINTERNALID TYPE STRING,
INSPECTIONCHARACTERISTIC TYPE STRING,
INSPRESULTITEMINTERNALID TYPE STRING,
INSPECTIONMETHOD TYPE STRING,
INSPECTIONSPECIFICATION TYPE STRING,
INSPECTIONMETHODVERSION TYPE STRING,
PLANT TYPE STRING,
CHARACTERISTICATTRIBUTECATALOG TYPE STRING,
CHARACTERISTICATTRIBUTECODE TYPE STRING,
CHARACTERISTICATTRIBUTECODEGRP TYPE STRING,
CHARACTERISTICATTRIBUTECODETXT TYPE STRING,
INSPECTOR TYPE STRING,
INSPECTIONOPERATION TYPE STRING,
INSPSPECUPPERLIMIT TYPE STRING,
INSPSPECLOWERLIMIT TYPE STRING,
INSPSPECTARGETVALUE TYPE STRING,
INSPECTIONRESULTMEANVALUE TYPE STRING,
INSPECTIONSPECIFICATIONUNIT TYPE STRING,
INSPRESULTVALIDVALUESNUMBER TYPE STRING,
INSPCHARACTERISTICSAMPLESIZE TYPE STRING,
INSPECTIONRESULTORIGINALVALUE TYPE STRING,
LASTCHANGEDBYUSER TYPE STRING,
CREATEDBYUSER TYPE STRING,
INSPRSLTFREEDEFINEDTESTEQUIP TYPE STRING,
INSPECTIONRESULTITEM TYPE STRING,
INSPECTIONRESULTTEXT TYPE STRING,
INSPRESULTATTRIBUTEISVALID TYPE STRING,
INSPSPECISQUANTITATIVE TYPE STRING,
INSPSPECRECORDINGTYPE TYPE STRING,
INSPSPECDECIMALPLACES TYPE STRING,
INSPSPECSUMMARIZEDDCMLPLACES TYPE STRING,
INSPRESULTVALUEINTERNALID TYPE STRING,
INSPECTIONRESULTMEASUREDVALUE TYPE STRING,
INSPECTIONVALUATIONRESULT TYPE STRING,
INSPECTIONRESULTATTRIBUTE TYPE STRING,
INSPECTIONRESULTATTRIBUTETEXT TYPE STRING,
INSPECTIONVALUATIONRESULTTEXT TYPE STRING,
INSPECTIONLOTTYPE TYPE STRING,
SERIALNUMBERPROFILE TYPE STRING,
INSPLOTISSERIALNMBRPOSSIBLE TYPE STRING,
MATLQUALITYAUTHORIZATIONGROUP TYPE STRING,END OF T_EKKO_STR. DATA: WA_CQMCHARESULTINFO_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_CQMCHARESULTINFO_STR-MANDT sy-vline
WA_CQMCHARESULTINFO_STR-INSPECTIONLOT sy-vline
WA_CQMCHARESULTINFO_STR-INSPPLANOPERATIONINTERNALID sy-vline
WA_CQMCHARESULTINFO_STR-INSPECTIONSUBSETINTERNALID sy-vline
WA_CQMCHARESULTINFO_STR-INSPECTIONCHARACTERISTIC sy-vline
WA_CQMCHARESULTINFO_STR-INSPRESULTITEMINTERNALID sy-vline
WA_CQMCHARESULTINFO_STR-INSPECTIONMETHOD sy-vline
WA_CQMCHARESULTINFO_STR-INSPECTIONSPECIFICATION sy-vline
WA_CQMCHARESULTINFO_STR-INSPECTIONMETHODVERSION sy-vline
WA_CQMCHARESULTINFO_STR-PLANT sy-vline
WA_CQMCHARESULTINFO_STR-CHARACTERISTICATTRIBUTECATALOG sy-vline
WA_CQMCHARESULTINFO_STR-CHARACTERISTICATTRIBUTECODE sy-vline
WA_CQMCHARESULTINFO_STR-CHARACTERISTICATTRIBUTECODEGRP sy-vline
WA_CQMCHARESULTINFO_STR-CHARACTERISTICATTRIBUTECODETXT sy-vline
WA_CQMCHARESULTINFO_STR-INSPECTOR sy-vline
WA_CQMCHARESULTINFO_STR-INSPECTIONOPERATION sy-vline
WA_CQMCHARESULTINFO_STR-INSPSPECUPPERLIMIT sy-vline
WA_CQMCHARESULTINFO_STR-INSPSPECLOWERLIMIT sy-vline
WA_CQMCHARESULTINFO_STR-INSPSPECTARGETVALUE sy-vline
WA_CQMCHARESULTINFO_STR-INSPECTIONRESULTMEANVALUE sy-vline
WA_CQMCHARESULTINFO_STR-INSPECTIONSPECIFICATIONUNIT sy-vline
WA_CQMCHARESULTINFO_STR-INSPRESULTVALIDVALUESNUMBER sy-vline
WA_CQMCHARESULTINFO_STR-INSPCHARACTERISTICSAMPLESIZE sy-vline
WA_CQMCHARESULTINFO_STR-INSPECTIONRESULTORIGINALVALUE sy-vline
WA_CQMCHARESULTINFO_STR-LASTCHANGEDBYUSER sy-vline
WA_CQMCHARESULTINFO_STR-CREATEDBYUSER sy-vline
WA_CQMCHARESULTINFO_STR-INSPRSLTFREEDEFINEDTESTEQUIP sy-vline
WA_CQMCHARESULTINFO_STR-INSPECTIONRESULTITEM sy-vline
WA_CQMCHARESULTINFO_STR-INSPECTIONRESULTTEXT sy-vline
WA_CQMCHARESULTINFO_STR-INSPRESULTATTRIBUTEISVALID sy-vline
WA_CQMCHARESULTINFO_STR-INSPSPECISQUANTITATIVE sy-vline
WA_CQMCHARESULTINFO_STR-INSPSPECRECORDINGTYPE sy-vline
WA_CQMCHARESULTINFO_STR-INSPSPECDECIMALPLACES sy-vline
WA_CQMCHARESULTINFO_STR-INSPSPECSUMMARIZEDDCMLPLACES sy-vline
WA_CQMCHARESULTINFO_STR-INSPRESULTVALUEINTERNALID sy-vline
WA_CQMCHARESULTINFO_STR-INSPECTIONRESULTMEASUREDVALUE sy-vline
WA_CQMCHARESULTINFO_STR-INSPECTIONVALUATIONRESULT sy-vline
WA_CQMCHARESULTINFO_STR-INSPECTIONRESULTATTRIBUTE sy-vline
WA_CQMCHARESULTINFO_STR-INSPECTIONRESULTATTRIBUTETEXT sy-vline
WA_CQMCHARESULTINFO_STR-INSPECTIONVALUATIONRESULTTEXT sy-vline
WA_CQMCHARESULTINFO_STR-INSPECTIONLOTTYPE sy-vline
WA_CQMCHARESULTINFO_STR-SERIALNUMBERPROFILE sy-vline
WA_CQMCHARESULTINFO_STR-INSPLOTISSERIALNMBRPOSSIBLE sy-vline
WA_CQMCHARESULTINFO_STR-MATLQUALITYAUTHORIZATIONGROUP sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.