ABAP Select data from SAP table CRMS4S_FSM_EQUIPMENT_REPL into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP CRMS4S_FSM_EQUIPMENT_REPL table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to CRMS4S_FSM_EQUIPMENT_REPL. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the CRMS4S_FSM_EQUIPMENT_REPL table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_CRMS4S_FSM_EQUIPMENT_REPL TYPE STANDARD TABLE OF CRMS4S_FSM_EQUIPMENT_REPL, WA_CRMS4S_FSM_EQUIPMENT_REPL TYPE CRMS4S_FSM_EQUIPMENT_REPL, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <CRMS4S_FSM_EQUIPMENT_REPL> TYPE CRMS4S_FSM_EQUIPMENT_REPL. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_CRMS4S_FSM_EQUIPMENT_REPL. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM CRMS4S_FSM_EQUIPMENT_REPL INTO TABLE IT_CRMS4S_FSM_EQUIPMENT_REPL. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM CRMS4S_FSM_EQUIPMENT_REPL * INTO TABLE @DATA(IT_CRMS4S_FSM_EQUIPMENT_REPL2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_CRMS4S_FSM_EQUIPMENT_REPL INDEX 1 INTO DATA(WA_CRMS4S_FSM_EQUIPMENT_REPL2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_CRMS4S_FSM_EQUIPMENT_REPL ASSIGNING <CRMS4S_FSM_EQUIPMENT_REPL>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<CRMS4S_FSM_EQUIPMENT_REPL>-BUSINESSPARTNER = 1.
<CRMS4S_FSM_EQUIPMENT_REPL>-MANUFACTURERSERIALNUMBER = 1.
<CRMS4S_FSM_EQUIPMENT_REPL>-INACTIVE = 1.
<CRMS4S_FSM_EQUIPMENT_REPL>-CONTACT = 1.
<CRMS4S_FSM_EQUIPMENT_REPL>-RESPONSIBLE = 1.
ENDLOOP. LOOP AT IT_CRMS4S_FSM_EQUIPMENT_REPL INTO WA_CRMS4S_FSM_EQUIPMENT_REPL. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_CRMS4S_FSM_EQUIPMENT_REPL-ITEM, sy-vline,
WA_CRMS4S_FSM_EQUIPMENT_REPL-SERIALNUMBER, sy-vline,
WA_CRMS4S_FSM_EQUIPMENT_REPL-TYPE, sy-vline,
WA_CRMS4S_FSM_EQUIPMENT_REPL-EXTERNALID, sy-vline,
WA_CRMS4S_FSM_EQUIPMENT_REPL-PARENTID, sy-vline,
WA_CRMS4S_FSM_EQUIPMENT_REPL-NAME, sy-vline.
ENDLOOP. *Add any further fields from structure WA_CRMS4S_FSM_EQUIPMENT_REPL you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_CRMS4S_FSM_EQUIPMENT_REPL TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_CRMS4S_FSM_EQUIPMENT_REPL INTO WA_CRMS4S_FSM_EQUIPMENT_REPL. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_CRMS4S_FSM_EQUIPMENT_REPL_STR,
BUSINESSPARTNER TYPE STRING,
MANUFACTURERSERIALNUMBER TYPE STRING,
INACTIVE TYPE STRING,
CONTACT TYPE STRING,
RESPONSIBLE TYPE STRING,
ITEM TYPE STRING,
SERIALNUMBER TYPE STRING,
TYPE TYPE STRING,
EXTERNALID TYPE STRING,
PARENTID TYPE STRING,
NAME TYPE STRING,
LOCATION TYPE STRING,
STATUS TYPE STRING,
OBJECTCATEGORY TYPE STRING,END OF T_EKKO_STR. DATA: WA_CRMS4S_FSM_EQUIPMENT_REPL_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_CRMS4S_FSM_EQUIPMENT_REPL_STR-BUSINESSPARTNER sy-vline
WA_CRMS4S_FSM_EQUIPMENT_REPL_STR-MANUFACTURERSERIALNUMBER sy-vline
WA_CRMS4S_FSM_EQUIPMENT_REPL_STR-INACTIVE sy-vline
WA_CRMS4S_FSM_EQUIPMENT_REPL_STR-CONTACT sy-vline
WA_CRMS4S_FSM_EQUIPMENT_REPL_STR-RESPONSIBLE sy-vline
WA_CRMS4S_FSM_EQUIPMENT_REPL_STR-ITEM sy-vline
WA_CRMS4S_FSM_EQUIPMENT_REPL_STR-SERIALNUMBER sy-vline
WA_CRMS4S_FSM_EQUIPMENT_REPL_STR-TYPE sy-vline
WA_CRMS4S_FSM_EQUIPMENT_REPL_STR-EXTERNALID sy-vline
WA_CRMS4S_FSM_EQUIPMENT_REPL_STR-PARENTID sy-vline
WA_CRMS4S_FSM_EQUIPMENT_REPL_STR-NAME sy-vline
WA_CRMS4S_FSM_EQUIPMENT_REPL_STR-LOCATION sy-vline
WA_CRMS4S_FSM_EQUIPMENT_REPL_STR-STATUS sy-vline
WA_CRMS4S_FSM_EQUIPMENT_REPL_STR-OBJECTCATEGORY sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.