ABAP Select data from SAP table CRMT_CT_INBOX_WF_DETAIL_ATTR into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP CRMT_CT_INBOX_WF_DETAIL_ATTR table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to CRMT_CT_INBOX_WF_DETAIL_ATTR. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the CRMT_CT_INBOX_WF_DETAIL_ATTR table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_CRMT_CT_INBOX_WF_DETAIL_ATTR TYPE STANDARD TABLE OF CRMT_CT_INBOX_WF_DETAIL_ATTR, WA_CRMT_CT_INBOX_WF_DETAIL_ATTR TYPE CRMT_CT_INBOX_WF_DETAIL_ATTR, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <CRMT_CT_INBOX_WF_DETAIL_ATTR> TYPE CRMT_CT_INBOX_WF_DETAIL_ATTR. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_CRMT_CT_INBOX_WF_DETAIL_ATTR. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM CRMT_CT_INBOX_WF_DETAIL_ATTR INTO TABLE IT_CRMT_CT_INBOX_WF_DETAIL_ATTR. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM CRMT_CT_INBOX_WF_DETAIL_ATTR * INTO TABLE @DATA(IT_CRMT_CT_INBOX_WF_DETAIL_ATTR2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_CRMT_CT_INBOX_WF_DETAIL_ATTR INDEX 1 INTO DATA(WA_CRMT_CT_INBOX_WF_DETAIL_ATTR2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_CRMT_CT_INBOX_WF_DETAIL_ATTR ASSIGNING <CRMT_CT_INBOX_WF_DETAIL_ATTR>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<CRMT_CT_INBOX_WF_DETAIL_ATTR>-WI_ID = 1.
<CRMT_CT_INBOX_WF_DETAIL_ATTR>-WI_LOGSYS = 1.
<CRMT_CT_INBOX_WF_DETAIL_ATTR>-GUID = 1.
<CRMT_CT_INBOX_WF_DETAIL_ATTR>-WI_DH_STAT = 1.
<CRMT_CT_INBOX_WF_DETAIL_ATTR>-WIZ_DH_STATTEXT = 1.
ENDLOOP. LOOP AT IT_CRMT_CT_INBOX_WF_DETAIL_ATTR INTO WA_CRMT_CT_INBOX_WF_DETAIL_ATTR. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_CRMT_CT_INBOX_WF_DETAIL_ATTR-WI_CR_TIMEIO, sy-vline,
WA_CRMT_CT_INBOX_WF_DETAIL_ATTR-WI_DSD, sy-vline,
WA_CRMT_CT_INBOX_WF_DETAIL_ATTR-WI_DST, sy-vline,
WA_CRMT_CT_INBOX_WF_DETAIL_ATTR-WI_DSD_FTD, sy-vline,
WA_CRMT_CT_INBOX_WF_DETAIL_ATTR-WI_DST_FTD, sy-vline,
WA_CRMT_CT_INBOX_WF_DETAIL_ATTR-WI_DS_TIMEIO, sy-vline.
ENDLOOP. *Add any further fields from structure WA_CRMT_CT_INBOX_WF_DETAIL_ATTR you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_CRMT_CT_INBOX_WF_DETAIL_ATTR TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_CRMT_CT_INBOX_WF_DETAIL_ATTR INTO WA_CRMT_CT_INBOX_WF_DETAIL_ATTR. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ALPHA, internal->external for field WI_LOGSYS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CRMT_CT_INBOX_WF_DETAIL_ATTR-WI_LOGSYS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CRMT_CT_INBOX_WF_DETAIL_ATTR-WI_LOGSYS.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_CRMT_CT_INBOX_WF_DETAIL_ATTR_STR,
WI_ID TYPE STRING,
WI_LOGSYS TYPE STRING,
GUID TYPE STRING,
WI_DH_STAT TYPE STRING,
WIZ_DH_STATTEXT TYPE STRING,
WI_CR_TIMEIO TYPE STRING,
WI_DSD TYPE STRING,
WI_DST TYPE STRING,
WI_DSD_FTD TYPE STRING,
WI_DST_FTD TYPE STRING,
WI_DS_TIMEIO TYPE STRING,
WI_LSD TYPE STRING,
WI_LST TYPE STRING,
WI_LSD_FTD TYPE STRING,
WI_LST_FTD TYPE STRING,
WI_LS_TIMEIO TYPE STRING,
WI_DED TYPE STRING,
WI_DET TYPE STRING,
WI_DED_FTD TYPE STRING,
WI_DET_FTD TYPE STRING,
WI_DE_TIMEIO TYPE STRING,
WI_LE_TIMEIO TYPE STRING,
WI_CHCKWI TYPE STRING,
TOP_WI_ID TYPE STRING,
NOTE_COUNT TYPE STRING,
EXEC_TIME TYPE STRING,
WI_AED TYPE STRING,
WI_AET TYPE STRING,
WI_AED_FTD TYPE STRING,
WI_AET_FTD TYPE STRING,
WI_AE_TIMEIO TYPE STRING,
WI_RESULT TYPE STRING,END OF T_EKKO_STR. DATA: WA_CRMT_CT_INBOX_WF_DETAIL_ATTR_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_CRMT_CT_INBOX_WF_DETAIL_ATTR_STR-WI_ID sy-vline
WA_CRMT_CT_INBOX_WF_DETAIL_ATTR_STR-WI_LOGSYS sy-vline
WA_CRMT_CT_INBOX_WF_DETAIL_ATTR_STR-GUID sy-vline
WA_CRMT_CT_INBOX_WF_DETAIL_ATTR_STR-WI_DH_STAT sy-vline
WA_CRMT_CT_INBOX_WF_DETAIL_ATTR_STR-WIZ_DH_STATTEXT sy-vline
WA_CRMT_CT_INBOX_WF_DETAIL_ATTR_STR-WI_CR_TIMEIO sy-vline
WA_CRMT_CT_INBOX_WF_DETAIL_ATTR_STR-WI_DSD sy-vline
WA_CRMT_CT_INBOX_WF_DETAIL_ATTR_STR-WI_DST sy-vline
WA_CRMT_CT_INBOX_WF_DETAIL_ATTR_STR-WI_DSD_FTD sy-vline
WA_CRMT_CT_INBOX_WF_DETAIL_ATTR_STR-WI_DST_FTD sy-vline
WA_CRMT_CT_INBOX_WF_DETAIL_ATTR_STR-WI_DS_TIMEIO sy-vline
WA_CRMT_CT_INBOX_WF_DETAIL_ATTR_STR-WI_LSD sy-vline
WA_CRMT_CT_INBOX_WF_DETAIL_ATTR_STR-WI_LST sy-vline
WA_CRMT_CT_INBOX_WF_DETAIL_ATTR_STR-WI_LSD_FTD sy-vline
WA_CRMT_CT_INBOX_WF_DETAIL_ATTR_STR-WI_LST_FTD sy-vline
WA_CRMT_CT_INBOX_WF_DETAIL_ATTR_STR-WI_LS_TIMEIO sy-vline
WA_CRMT_CT_INBOX_WF_DETAIL_ATTR_STR-WI_DED sy-vline
WA_CRMT_CT_INBOX_WF_DETAIL_ATTR_STR-WI_DET sy-vline
WA_CRMT_CT_INBOX_WF_DETAIL_ATTR_STR-WI_DED_FTD sy-vline
WA_CRMT_CT_INBOX_WF_DETAIL_ATTR_STR-WI_DET_FTD sy-vline
WA_CRMT_CT_INBOX_WF_DETAIL_ATTR_STR-WI_DE_TIMEIO sy-vline
WA_CRMT_CT_INBOX_WF_DETAIL_ATTR_STR-WI_LE_TIMEIO sy-vline
WA_CRMT_CT_INBOX_WF_DETAIL_ATTR_STR-WI_CHCKWI sy-vline
WA_CRMT_CT_INBOX_WF_DETAIL_ATTR_STR-TOP_WI_ID sy-vline
WA_CRMT_CT_INBOX_WF_DETAIL_ATTR_STR-NOTE_COUNT sy-vline
WA_CRMT_CT_INBOX_WF_DETAIL_ATTR_STR-EXEC_TIME sy-vline
WA_CRMT_CT_INBOX_WF_DETAIL_ATTR_STR-WI_AED sy-vline
WA_CRMT_CT_INBOX_WF_DETAIL_ATTR_STR-WI_AET sy-vline
WA_CRMT_CT_INBOX_WF_DETAIL_ATTR_STR-WI_AED_FTD sy-vline
WA_CRMT_CT_INBOX_WF_DETAIL_ATTR_STR-WI_AET_FTD sy-vline
WA_CRMT_CT_INBOX_WF_DETAIL_ATTR_STR-WI_AE_TIMEIO sy-vline
WA_CRMT_CT_INBOX_WF_DETAIL_ATTR_STR-WI_RESULT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.