ABAP Select data from SAP table CRMT_ISU_PRC_SIMU_DOC_I_BULK into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP CRMT_ISU_PRC_SIMU_DOC_I_BULK table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to CRMT_ISU_PRC_SIMU_DOC_I_BULK. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the CRMT_ISU_PRC_SIMU_DOC_I_BULK table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_CRMT_ISU_PRC_SIMU_DOC_I_BULK TYPE STANDARD TABLE OF CRMT_ISU_PRC_SIMU_DOC_I_BULK,
      WA_CRMT_ISU_PRC_SIMU_DOC_I_BULK TYPE CRMT_ISU_PRC_SIMU_DOC_I_BULK,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <CRMT_ISU_PRC_SIMU_DOC_I_BULK> TYPE CRMT_ISU_PRC_SIMU_DOC_I_BULK.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_CRMT_ISU_PRC_SIMU_DOC_I_BULK.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM CRMT_ISU_PRC_SIMU_DOC_I_BULK
  INTO TABLE IT_CRMT_ISU_PRC_SIMU_DOC_I_BULK.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM CRMT_ISU_PRC_SIMU_DOC_I_BULK
*  INTO TABLE @DATA(IT_CRMT_ISU_PRC_SIMU_DOC_I_BULK2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_CRMT_ISU_PRC_SIMU_DOC_I_BULK INDEX 1 INTO DATA(WA_CRMT_ISU_PRC_SIMU_DOC_I_BULK2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_CRMT_ISU_PRC_SIMU_DOC_I_BULK ASSIGNING <CRMT_ISU_PRC_SIMU_DOC_I_BULK>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<CRMT_ISU_PRC_SIMU_DOC_I_BULK>-SIMREQGUID = 1.
<CRMT_ISU_PRC_SIMU_DOC_I_BULK>-DOCUMENTID = 1.
<CRMT_ISU_PRC_SIMU_DOC_I_BULK>-ITEMNUMBER = 1.
<CRMT_ISU_PRC_SIMU_DOC_I_BULK>-NETAMOUNT = 1.
<CRMT_ISU_PRC_SIMU_DOC_I_BULK>-GROSSAMOUNT = 1.
ENDLOOP.

LOOP AT IT_CRMT_ISU_PRC_SIMU_DOC_I_BULK INTO WA_CRMT_ISU_PRC_SIMU_DOC_I_BULK.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_CRMT_ISU_PRC_SIMU_DOC_I_BULK-TAXCODE, sy-vline,
WA_CRMT_ISU_PRC_SIMU_DOC_I_BULK-PRICEAMOUNT, sy-vline,
WA_CRMT_ISU_PRC_SIMU_DOC_I_BULK-PRICEID, sy-vline,
WA_CRMT_ISU_PRC_SIMU_DOC_I_BULK-PRICETYPE, sy-vline,
WA_CRMT_ISU_PRC_SIMU_DOC_I_BULK-PRICELEVEL, sy-vline,
WA_CRMT_ISU_PRC_SIMU_DOC_I_BULK-BILLINGQUANTITY, sy-vline.
ENDLOOP. *Add any further fields from structure WA_CRMT_ISU_PRC_SIMU_DOC_I_BULK you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_CRMT_ISU_PRC_SIMU_DOC_I_BULK TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_CRMT_ISU_PRC_SIMU_DOC_I_BULK INTO WA_CRMT_ISU_PRC_SIMU_DOC_I_BULK. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_CRMT_ISU_PRC_SIMU_DOC_I_BULK_STR,
SIMREQGUID TYPE STRING,
DOCUMENTID TYPE STRING,
ITEMNUMBER TYPE STRING,
NETAMOUNT TYPE STRING,
GROSSAMOUNT TYPE STRING,
TAXCODE TYPE STRING,
PRICEAMOUNT TYPE STRING,
PRICEID TYPE STRING,
PRICETYPE TYPE STRING,
PRICELEVEL TYPE STRING,
BILLINGQUANTITY TYPE STRING,
UNIT TYPE STRING,
PERIODSTART TYPE STRING,
PERIODEND TYPE STRING,
DEVICE TYPE STRING,
REGISTER TYPE STRING,
EQUIPMENTNUMBER TYPE STRING,
SUBTRANSACTION TYPE STRING,
POSTINGRELEVANT TYPE STRING,
PRINTRELEVANT TYPE STRING,
BUDGETBILLINGRELEVANT TYPE STRING,
LINEITEMTYPE TYPE STRING,
PRESORTINGKEY TYPE STRING,
RATECATEGORY TYPE STRING,
RATE TYPE STRING,
CURRENCY TYPE STRING,END OF T_EKKO_STR. DATA: WA_CRMT_ISU_PRC_SIMU_DOC_I_BULK_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_CRMT_ISU_PRC_SIMU_DOC_I_BULK_STR-SIMREQGUID sy-vline
WA_CRMT_ISU_PRC_SIMU_DOC_I_BULK_STR-DOCUMENTID sy-vline
WA_CRMT_ISU_PRC_SIMU_DOC_I_BULK_STR-ITEMNUMBER sy-vline
WA_CRMT_ISU_PRC_SIMU_DOC_I_BULK_STR-NETAMOUNT sy-vline
WA_CRMT_ISU_PRC_SIMU_DOC_I_BULK_STR-GROSSAMOUNT sy-vline
WA_CRMT_ISU_PRC_SIMU_DOC_I_BULK_STR-TAXCODE sy-vline
WA_CRMT_ISU_PRC_SIMU_DOC_I_BULK_STR-PRICEAMOUNT sy-vline
WA_CRMT_ISU_PRC_SIMU_DOC_I_BULK_STR-PRICEID sy-vline
WA_CRMT_ISU_PRC_SIMU_DOC_I_BULK_STR-PRICETYPE sy-vline
WA_CRMT_ISU_PRC_SIMU_DOC_I_BULK_STR-PRICELEVEL sy-vline
WA_CRMT_ISU_PRC_SIMU_DOC_I_BULK_STR-BILLINGQUANTITY sy-vline
WA_CRMT_ISU_PRC_SIMU_DOC_I_BULK_STR-UNIT sy-vline
WA_CRMT_ISU_PRC_SIMU_DOC_I_BULK_STR-PERIODSTART sy-vline
WA_CRMT_ISU_PRC_SIMU_DOC_I_BULK_STR-PERIODEND sy-vline
WA_CRMT_ISU_PRC_SIMU_DOC_I_BULK_STR-DEVICE sy-vline
WA_CRMT_ISU_PRC_SIMU_DOC_I_BULK_STR-REGISTER sy-vline
WA_CRMT_ISU_PRC_SIMU_DOC_I_BULK_STR-EQUIPMENTNUMBER sy-vline
WA_CRMT_ISU_PRC_SIMU_DOC_I_BULK_STR-SUBTRANSACTION sy-vline
WA_CRMT_ISU_PRC_SIMU_DOC_I_BULK_STR-POSTINGRELEVANT sy-vline
WA_CRMT_ISU_PRC_SIMU_DOC_I_BULK_STR-PRINTRELEVANT sy-vline
WA_CRMT_ISU_PRC_SIMU_DOC_I_BULK_STR-BUDGETBILLINGRELEVANT sy-vline
WA_CRMT_ISU_PRC_SIMU_DOC_I_BULK_STR-LINEITEMTYPE sy-vline
WA_CRMT_ISU_PRC_SIMU_DOC_I_BULK_STR-PRESORTINGKEY sy-vline
WA_CRMT_ISU_PRC_SIMU_DOC_I_BULK_STR-RATECATEGORY sy-vline
WA_CRMT_ISU_PRC_SIMU_DOC_I_BULK_STR-RATE sy-vline
WA_CRMT_ISU_PRC_SIMU_DOC_I_BULK_STR-CURRENCY sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.