ABAP Select data from SAP table CTS_DWNOBJ into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP CTS_DWNOBJ table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to CTS_DWNOBJ. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the CTS_DWNOBJ table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_CTS_DWNOBJ TYPE STANDARD TABLE OF CTS_DWNOBJ,
      WA_CTS_DWNOBJ TYPE CTS_DWNOBJ,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <CTS_DWNOBJ> TYPE CTS_DWNOBJ.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_CTS_DWNOBJ.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM CTS_DWNOBJ
  INTO TABLE IT_CTS_DWNOBJ.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM CTS_DWNOBJ
*  INTO TABLE @DATA(IT_CTS_DWNOBJ2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_CTS_DWNOBJ INDEX 1 INTO DATA(WA_CTS_DWNOBJ2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_CTS_DWNOBJ ASSIGNING <CTS_DWNOBJ>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<CTS_DWNOBJ>-SID = 1.
<CTS_DWNOBJ>-PGMID = 1.
<CTS_DWNOBJ>-OBJECT = 1.
<CTS_DWNOBJ>-OBJNAME = 1.
<CTS_DWNOBJ>-KEY_4 = 1.
ENDLOOP.

LOOP AT IT_CTS_DWNOBJ INTO WA_CTS_DWNOBJ.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_CTS_DWNOBJ-IMPORTING_REQ, sy-vline,
WA_CTS_DWNOBJ-IMPORTED_REQ, sy-vline,
WA_CTS_DWNOBJ-IMPORTING_REQ_DESCR, sy-vline,
WA_CTS_DWNOBJ-IMPORTED_REQ_DESCR, sy-vline,
WA_CTS_DWNOBJ-IMPORTING_REQ_EXP, sy-vline,
WA_CTS_DWNOBJ-IMPORTED_REQ_EXP, sy-vline.
ENDLOOP. *Add any further fields from structure WA_CTS_DWNOBJ you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_CTS_DWNOBJ TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_CTS_DWNOBJ INTO WA_CTS_DWNOBJ. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_CTS_DWNOBJ_STR,
SID TYPE STRING,
PGMID TYPE STRING,
OBJECT TYPE STRING,
OBJNAME TYPE STRING,
KEY_4 TYPE STRING,
IMPORTING_REQ TYPE STRING,
IMPORTED_REQ TYPE STRING,
IMPORTING_REQ_DESCR TYPE STRING,
IMPORTED_REQ_DESCR TYPE STRING,
IMPORTING_REQ_EXP TYPE STRING,
IMPORTED_REQ_EXP TYPE STRING,
IMPORTED_REQ_IMP TYPE STRING,
OBJTYPEDESCR TYPE STRING,
NOTE TYPE STRING,
NON_ABAP_OBJ_ID TYPE STRING,END OF T_EKKO_STR. DATA: WA_CTS_DWNOBJ_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_CTS_DWNOBJ_STR-SID sy-vline
WA_CTS_DWNOBJ_STR-PGMID sy-vline
WA_CTS_DWNOBJ_STR-OBJECT sy-vline
WA_CTS_DWNOBJ_STR-OBJNAME sy-vline
WA_CTS_DWNOBJ_STR-KEY_4 sy-vline
WA_CTS_DWNOBJ_STR-IMPORTING_REQ sy-vline
WA_CTS_DWNOBJ_STR-IMPORTED_REQ sy-vline
WA_CTS_DWNOBJ_STR-IMPORTING_REQ_DESCR sy-vline
WA_CTS_DWNOBJ_STR-IMPORTED_REQ_DESCR sy-vline
WA_CTS_DWNOBJ_STR-IMPORTING_REQ_EXP sy-vline
WA_CTS_DWNOBJ_STR-IMPORTED_REQ_EXP sy-vline
WA_CTS_DWNOBJ_STR-IMPORTED_REQ_IMP sy-vline
WA_CTS_DWNOBJ_STR-OBJTYPEDESCR sy-vline
WA_CTS_DWNOBJ_STR-NOTE sy-vline
WA_CTS_DWNOBJ_STR-NON_ABAP_OBJ_ID sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.