ABAP Select data from SAP table DWN07 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP DWN07 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to DWN07. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the DWN07 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_DWN07 TYPE STANDARD TABLE OF DWN07,
      WA_DWN07 TYPE DWN07,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <DWN07> TYPE DWN07.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_DWN07.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM DWN07
  INTO TABLE IT_DWN07.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM DWN07
*  INTO TABLE @DATA(IT_DWN072).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_DWN07 INDEX 1 INTO DATA(WA_DWN072).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_DWN07 ASSIGNING <DWN07>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<DWN07>-MSEHI = 1.
<DWN07>-MSEHE = 1.
<DWN07>-NENNR = 1.
<DWN07>-ZAEHL = 1.
<DWN07>-MSSIE = 1.
ENDLOOP.

LOOP AT IT_DWN07 INTO WA_DWN07.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_DWN07-MSEHL, sy-vline,
WA_DWN07-ANDEC, sy-vline,
WA_DWN07-SOURCE_SYS, sy-vline,
ENDLOOP. *Add any further fields from structure WA_DWN07 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_DWN07 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_DWN07 INTO WA_DWN07. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit CUNIT, internal->external for field MSEHI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_DWN07-MSEHI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_DWN07-MSEHI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MSSIE CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_DWN07-MSSIE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_DWN07-MSSIE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SOURCE_SYS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_DWN07-SOURCE_SYS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_DWN07-SOURCE_SYS.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_DWN07_STR,
MSEHI TYPE STRING,
MSEHE TYPE STRING,
NENNR TYPE STRING,
ZAEHL TYPE STRING,
MSSIE TYPE STRING,
MSEHL TYPE STRING,
ANDEC TYPE STRING,
SOURCE_SYS TYPE STRING,END OF T_EKKO_STR. DATA: WA_DWN07_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_DWN07_STR-MSEHI sy-vline
WA_DWN07_STR-MSEHE sy-vline
WA_DWN07_STR-NENNR sy-vline
WA_DWN07_STR-ZAEHL sy-vline
WA_DWN07_STR-MSSIE sy-vline
WA_DWN07_STR-MSEHL sy-vline
WA_DWN07_STR-ANDEC sy-vline
WA_DWN07_STR-SOURCE_SYS sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.