ABAP Select data from SAP table E101CMDS_EI_SALES_DATA into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP E101CMDS_EI_SALES_DATA table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to E101CMDS_EI_SALES_DATA. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the E101CMDS_EI_SALES_DATA table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_E101CMDS_EI_SALES_DATA TYPE STANDARD TABLE OF E101CMDS_EI_SALES_DATA,
      WA_E101CMDS_EI_SALES_DATA TYPE E101CMDS_EI_SALES_DATA,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <E101CMDS_EI_SALES_DATA> TYPE E101CMDS_EI_SALES_DATA.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_E101CMDS_EI_SALES_DATA.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM E101CMDS_EI_SALES_DATA
  INTO TABLE IT_E101CMDS_EI_SALES_DATA.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM E101CMDS_EI_SALES_DATA
*  INTO TABLE @DATA(IT_E101CMDS_EI_SALES_DATA2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_E101CMDS_EI_SALES_DATA INDEX 1 INTO DATA(WA_E101CMDS_EI_SALES_DATA2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_E101CMDS_EI_SALES_DATA ASSIGNING <E101CMDS_EI_SALES_DATA>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<E101CMDS_EI_SALES_DATA>-APPL_SNAME = 1.
<E101CMDS_EI_SALES_DATA>-BEGRU = 1.
<E101CMDS_EI_SALES_DATA>-LOEVM = 1.
<E101CMDS_EI_SALES_DATA>-VERSG = 1.
<E101CMDS_EI_SALES_DATA>-AUFSD = 1.
ENDLOOP.

LOOP AT IT_E101CMDS_EI_SALES_DATA INTO WA_E101CMDS_EI_SALES_DATA.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_E101CMDS_EI_SALES_DATA-KALKS, sy-vline,
WA_E101CMDS_EI_SALES_DATA-KDGRP, sy-vline,
WA_E101CMDS_EI_SALES_DATA-BZIRK, sy-vline,
WA_E101CMDS_EI_SALES_DATA-KONDA, sy-vline,
WA_E101CMDS_EI_SALES_DATA-PLTYP, sy-vline,
WA_E101CMDS_EI_SALES_DATA-AWAHR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_E101CMDS_EI_SALES_DATA you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_E101CMDS_EI_SALES_DATA TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_E101CMDS_EI_SALES_DATA INTO WA_E101CMDS_EI_SALES_DATA. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_E101CMDS_EI_SALES_DATA_STR,
APPL_SNAME TYPE STRING,
BEGRU TYPE STRING,
LOEVM TYPE STRING,
VERSG TYPE STRING,
AUFSD TYPE STRING,
KALKS TYPE STRING,
KDGRP TYPE STRING,
BZIRK TYPE STRING,
KONDA TYPE STRING,
PLTYP TYPE STRING,
AWAHR TYPE STRING,
INCO1 TYPE STRING,
INCO2 TYPE STRING,
LIFSD TYPE STRING,
AUTLF TYPE STRING,
ANTLF TYPE STRING,
KZTLF TYPE STRING,
KZAZU TYPE STRING,
CHSPL TYPE STRING,
LPRIO TYPE STRING,
EIKTO TYPE STRING,
VSBED TYPE STRING,
FAKSD TYPE STRING,
MRNKZ TYPE STRING,
PERFK TYPE STRING,
PERRL TYPE STRING,
WAERS TYPE STRING,
KTGRD TYPE STRING,
ZTERM TYPE STRING,
VWERK TYPE STRING,
VKGRP TYPE STRING,
VKBUR TYPE STRING,
VSORT TYPE STRING,
KVGR1 TYPE STRING,
KVGR2 TYPE STRING,
KVGR3 TYPE STRING,
KVGR4 TYPE STRING,
KVGR5 TYPE STRING,
BOKRE TYPE STRING,
KURST TYPE STRING,
PRFRE TYPE STRING,
KLABC TYPE STRING,
KABSS TYPE STRING,
KKBER TYPE STRING,
CASSD TYPE STRING,
RDOFF TYPE STRING,
AGREL TYPE STRING,
MEGRU TYPE STRING,
UEBTO TYPE STRING,
UNTTO TYPE STRING,
UEBTK TYPE STRING,
PVKSM TYPE STRING,
PODKZ TYPE STRING,
PODTG TYPE STRING,
BLIND TYPE STRING,
PRAT1 TYPE STRING,
PRAT2 TYPE STRING,
PRAT3 TYPE STRING,
PRAT4 TYPE STRING,
PRAT5 TYPE STRING,
PRAT6 TYPE STRING,
PRAT7 TYPE STRING,
PRAT8 TYPE STRING,
PRAT9 TYPE STRING,
PRATA TYPE STRING,END OF T_EKKO_STR. DATA: WA_E101CMDS_EI_SALES_DATA_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_E101CMDS_EI_SALES_DATA_STR-APPL_SNAME sy-vline
WA_E101CMDS_EI_SALES_DATA_STR-BEGRU sy-vline
WA_E101CMDS_EI_SALES_DATA_STR-LOEVM sy-vline
WA_E101CMDS_EI_SALES_DATA_STR-VERSG sy-vline
WA_E101CMDS_EI_SALES_DATA_STR-AUFSD sy-vline
WA_E101CMDS_EI_SALES_DATA_STR-KALKS sy-vline
WA_E101CMDS_EI_SALES_DATA_STR-KDGRP sy-vline
WA_E101CMDS_EI_SALES_DATA_STR-BZIRK sy-vline
WA_E101CMDS_EI_SALES_DATA_STR-KONDA sy-vline
WA_E101CMDS_EI_SALES_DATA_STR-PLTYP sy-vline
WA_E101CMDS_EI_SALES_DATA_STR-AWAHR sy-vline
WA_E101CMDS_EI_SALES_DATA_STR-INCO1 sy-vline
WA_E101CMDS_EI_SALES_DATA_STR-INCO2 sy-vline
WA_E101CMDS_EI_SALES_DATA_STR-LIFSD sy-vline
WA_E101CMDS_EI_SALES_DATA_STR-AUTLF sy-vline
WA_E101CMDS_EI_SALES_DATA_STR-ANTLF sy-vline
WA_E101CMDS_EI_SALES_DATA_STR-KZTLF sy-vline
WA_E101CMDS_EI_SALES_DATA_STR-KZAZU sy-vline
WA_E101CMDS_EI_SALES_DATA_STR-CHSPL sy-vline
WA_E101CMDS_EI_SALES_DATA_STR-LPRIO sy-vline
WA_E101CMDS_EI_SALES_DATA_STR-EIKTO sy-vline
WA_E101CMDS_EI_SALES_DATA_STR-VSBED sy-vline
WA_E101CMDS_EI_SALES_DATA_STR-FAKSD sy-vline
WA_E101CMDS_EI_SALES_DATA_STR-MRNKZ sy-vline
WA_E101CMDS_EI_SALES_DATA_STR-PERFK sy-vline
WA_E101CMDS_EI_SALES_DATA_STR-PERRL sy-vline
WA_E101CMDS_EI_SALES_DATA_STR-WAERS sy-vline
WA_E101CMDS_EI_SALES_DATA_STR-KTGRD sy-vline
WA_E101CMDS_EI_SALES_DATA_STR-ZTERM sy-vline
WA_E101CMDS_EI_SALES_DATA_STR-VWERK sy-vline
WA_E101CMDS_EI_SALES_DATA_STR-VKGRP sy-vline
WA_E101CMDS_EI_SALES_DATA_STR-VKBUR sy-vline
WA_E101CMDS_EI_SALES_DATA_STR-VSORT sy-vline
WA_E101CMDS_EI_SALES_DATA_STR-KVGR1 sy-vline
WA_E101CMDS_EI_SALES_DATA_STR-KVGR2 sy-vline
WA_E101CMDS_EI_SALES_DATA_STR-KVGR3 sy-vline
WA_E101CMDS_EI_SALES_DATA_STR-KVGR4 sy-vline
WA_E101CMDS_EI_SALES_DATA_STR-KVGR5 sy-vline
WA_E101CMDS_EI_SALES_DATA_STR-BOKRE sy-vline
WA_E101CMDS_EI_SALES_DATA_STR-KURST sy-vline
WA_E101CMDS_EI_SALES_DATA_STR-PRFRE sy-vline
WA_E101CMDS_EI_SALES_DATA_STR-KLABC sy-vline
WA_E101CMDS_EI_SALES_DATA_STR-KABSS sy-vline
WA_E101CMDS_EI_SALES_DATA_STR-KKBER sy-vline
WA_E101CMDS_EI_SALES_DATA_STR-CASSD sy-vline
WA_E101CMDS_EI_SALES_DATA_STR-RDOFF sy-vline
WA_E101CMDS_EI_SALES_DATA_STR-AGREL sy-vline
WA_E101CMDS_EI_SALES_DATA_STR-MEGRU sy-vline
WA_E101CMDS_EI_SALES_DATA_STR-UEBTO sy-vline
WA_E101CMDS_EI_SALES_DATA_STR-UNTTO sy-vline
WA_E101CMDS_EI_SALES_DATA_STR-UEBTK sy-vline
WA_E101CMDS_EI_SALES_DATA_STR-PVKSM sy-vline
WA_E101CMDS_EI_SALES_DATA_STR-PODKZ sy-vline
WA_E101CMDS_EI_SALES_DATA_STR-PODTG sy-vline
WA_E101CMDS_EI_SALES_DATA_STR-BLIND sy-vline
WA_E101CMDS_EI_SALES_DATA_STR-PRAT1 sy-vline
WA_E101CMDS_EI_SALES_DATA_STR-PRAT2 sy-vline
WA_E101CMDS_EI_SALES_DATA_STR-PRAT3 sy-vline
WA_E101CMDS_EI_SALES_DATA_STR-PRAT4 sy-vline
WA_E101CMDS_EI_SALES_DATA_STR-PRAT5 sy-vline
WA_E101CMDS_EI_SALES_DATA_STR-PRAT6 sy-vline
WA_E101CMDS_EI_SALES_DATA_STR-PRAT7 sy-vline
WA_E101CMDS_EI_SALES_DATA_STR-PRAT8 sy-vline
WA_E101CMDS_EI_SALES_DATA_STR-PRAT9 sy-vline
WA_E101CMDS_EI_SALES_DATA_STR-PRATA sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.