ABAP Select data from SAP table E1BP10001PRDALTUOM2 into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP E1BP10001PRDALTUOM2 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to E1BP10001PRDALTUOM2. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the E1BP10001PRDALTUOM2 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_E1BP10001PRDALTUOM2 TYPE STANDARD TABLE OF E1BP10001PRDALTUOM2, WA_E1BP10001PRDALTUOM2 TYPE E1BP10001PRDALTUOM2, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <E1BP10001PRDALTUOM2> TYPE E1BP10001PRDALTUOM2. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_E1BP10001PRDALTUOM2. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM E1BP10001PRDALTUOM2 INTO TABLE IT_E1BP10001PRDALTUOM2. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM E1BP10001PRDALTUOM2 * INTO TABLE @DATA(IT_E1BP10001PRDALTUOM22). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_E1BP10001PRDALTUOM2 INDEX 1 INTO DATA(WA_E1BP10001PRDALTUOM22). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_E1BP10001PRDALTUOM2 ASSIGNING <E1BP10001PRDALTUOM2>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<E1BP10001PRDALTUOM2>-PRODUCT_ID = 1.
<E1BP10001PRDALTUOM2>-PRODUCT = 1.
<E1BP10001PRDALTUOM2>-PRODUCT_INT = 1.
<E1BP10001PRDALTUOM2>-ALTERNATIVE_UOM = 1.
<E1BP10001PRDALTUOM2>-ALTERNATIVE_UOM_ISO = 1.
ENDLOOP. LOOP AT IT_E1BP10001PRDALTUOM2 INTO WA_E1BP10001PRDALTUOM2. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_E1BP10001PRDALTUOM2-NUMERATOR, sy-vline,
WA_E1BP10001PRDALTUOM2-DENOMINATOR, sy-vline,
WA_E1BP10001PRDALTUOM2-INTERNATIONAL_ARTICLE_NUMBER, sy-vline,
WA_E1BP10001PRDALTUOM2-GROSS_WEIGHT, sy-vline,
WA_E1BP10001PRDALTUOM2-NET_WEIGHT, sy-vline,
WA_E1BP10001PRDALTUOM2-WEIGHT_UOM, sy-vline.
ENDLOOP. *Add any further fields from structure WA_E1BP10001PRDALTUOM2 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_E1BP10001PRDALTUOM2 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_E1BP10001PRDALTUOM2 INTO WA_E1BP10001PRDALTUOM2. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_E1BP10001PRDALTUOM2_STR,
PRODUCT_ID TYPE STRING,
PRODUCT TYPE STRING,
PRODUCT_INT TYPE STRING,
ALTERNATIVE_UOM TYPE STRING,
ALTERNATIVE_UOM_ISO TYPE STRING,
NUMERATOR TYPE STRING,
DENOMINATOR TYPE STRING,
INTERNATIONAL_ARTICLE_NUMBER TYPE STRING,
GROSS_WEIGHT TYPE STRING,
NET_WEIGHT TYPE STRING,
WEIGHT_UOM TYPE STRING,
WEIGHT_UOM_ISO TYPE STRING,
VOLUME TYPE STRING,
VOLUME_UOM TYPE STRING,
VOLUME_UOM_ISO TYPE STRING,
LENGTH TYPE STRING,
WIDTH TYPE STRING,
HEIGHT TYPE STRING,
DIMENSION_UOM TYPE STRING,
DIMENSION_UOM_ISO TYPE STRING,
CAPACITY_CONSUMPTION TYPE STRING,
MAX_STACK TYPE STRING,
NESTED_VOLUME TYPE STRING,
EAN_CATEGORY TYPE STRING,
GTIN_VARIANT TYPE STRING,
PRDTYPE TYPE STRING,
UOM_CATEGORY TYPE STRING,END OF T_EKKO_STR. DATA: WA_E1BP10001PRDALTUOM2_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_E1BP10001PRDALTUOM2_STR-PRODUCT_ID sy-vline
WA_E1BP10001PRDALTUOM2_STR-PRODUCT sy-vline
WA_E1BP10001PRDALTUOM2_STR-PRODUCT_INT sy-vline
WA_E1BP10001PRDALTUOM2_STR-ALTERNATIVE_UOM sy-vline
WA_E1BP10001PRDALTUOM2_STR-ALTERNATIVE_UOM_ISO sy-vline
WA_E1BP10001PRDALTUOM2_STR-NUMERATOR sy-vline
WA_E1BP10001PRDALTUOM2_STR-DENOMINATOR sy-vline
WA_E1BP10001PRDALTUOM2_STR-INTERNATIONAL_ARTICLE_NUMBER sy-vline
WA_E1BP10001PRDALTUOM2_STR-GROSS_WEIGHT sy-vline
WA_E1BP10001PRDALTUOM2_STR-NET_WEIGHT sy-vline
WA_E1BP10001PRDALTUOM2_STR-WEIGHT_UOM sy-vline
WA_E1BP10001PRDALTUOM2_STR-WEIGHT_UOM_ISO sy-vline
WA_E1BP10001PRDALTUOM2_STR-VOLUME sy-vline
WA_E1BP10001PRDALTUOM2_STR-VOLUME_UOM sy-vline
WA_E1BP10001PRDALTUOM2_STR-VOLUME_UOM_ISO sy-vline
WA_E1BP10001PRDALTUOM2_STR-LENGTH sy-vline
WA_E1BP10001PRDALTUOM2_STR-WIDTH sy-vline
WA_E1BP10001PRDALTUOM2_STR-HEIGHT sy-vline
WA_E1BP10001PRDALTUOM2_STR-DIMENSION_UOM sy-vline
WA_E1BP10001PRDALTUOM2_STR-DIMENSION_UOM_ISO sy-vline
WA_E1BP10001PRDALTUOM2_STR-CAPACITY_CONSUMPTION sy-vline
WA_E1BP10001PRDALTUOM2_STR-MAX_STACK sy-vline
WA_E1BP10001PRDALTUOM2_STR-NESTED_VOLUME sy-vline
WA_E1BP10001PRDALTUOM2_STR-EAN_CATEGORY sy-vline
WA_E1BP10001PRDALTUOM2_STR-GTIN_VARIANT sy-vline
WA_E1BP10001PRDALTUOM2_STR-PRDTYPE sy-vline
WA_E1BP10001PRDALTUOM2_STR-UOM_CATEGORY sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.