ABAP Select data from SAP table E1BP1198_SR_POP into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP E1BP1198_SR_POP table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to E1BP1198_SR_POP. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the E1BP1198_SR_POP table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_E1BP1198_SR_POP TYPE STANDARD TABLE OF E1BP1198_SR_POP, WA_E1BP1198_SR_POP TYPE E1BP1198_SR_POP, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <E1BP1198_SR_POP> TYPE E1BP1198_SR_POP. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_E1BP1198_SR_POP. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM E1BP1198_SR_POP INTO TABLE IT_E1BP1198_SR_POP. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM E1BP1198_SR_POP * INTO TABLE @DATA(IT_E1BP1198_SR_POP2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_E1BP1198_SR_POP INDEX 1 INTO DATA(WA_E1BP1198_SR_POP2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_E1BP1198_SR_POP ASSIGNING <E1BP1198_SR_POP>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<E1BP1198_SR_POP>-MANDT = 1.
<E1BP1198_SR_POP>-IDENTIFIER = 1.
<E1BP1198_SR_POP>-CHANGE_NO = 1.
<E1BP1198_SR_POP>-IDENTIFIER_MAST = 1.
<E1BP1198_SR_POP>-IDENTIFIER_ROOT = 1.
ENDLOOP. LOOP AT IT_E1BP1198_SR_POP INTO WA_E1BP1198_SR_POP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_E1BP1198_SR_POP-CHANGE_NO_ROOT, sy-vline,
WA_E1BP1198_SR_POP-NODE_NAME, sy-vline,
WA_E1BP1198_SR_POP-NODE_TYPE, sy-vline,
WA_E1BP1198_SR_POP-NODE_CNT, sy-vline,
WA_E1BP1198_SR_POP-PNTXCNT, sy-vline,
WA_E1BP1198_SR_POP-POBNR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_E1BP1198_SR_POP you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_E1BP1198_SR_POP TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_E1BP1198_SR_POP INTO WA_E1BP1198_SR_POP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_E1BP1198_SR_POP_STR,
MANDT TYPE STRING,
IDENTIFIER TYPE STRING,
CHANGE_NO TYPE STRING,
IDENTIFIER_MAST TYPE STRING,
IDENTIFIER_ROOT TYPE STRING,
CHANGE_NO_ROOT TYPE STRING,
NODE_NAME TYPE STRING,
NODE_TYPE TYPE STRING,
NODE_CNT TYPE STRING,
PNTXCNT TYPE STRING,
POBNR TYPE STRING,
VALFROM TYPE STRING,
VALTO TYPE STRING,
LOT_SIZE_MIN TYPE STRING,
LOT_SIZE_MAX TYPE STRING,
QUANTITY_UNIT TYPE STRING,
QUANTITY_UNIT_ISO TYPE STRING,
OTYPE TYPE STRING,
REALO TYPE STRING,
POB_TIMSTAMP TYPE STRING,
COPY_FROM TYPE STRING,
FLG_INNR TYPE STRING,
AUTH_GRP TYPE STRING,
RECORD_NO TYPE STRING,
SUBCATEGRY TYPE STRING,
SUBSTANCE TYPE STRING,
CREATED_DATE TYPE STRING,
CREATED_BY TYPE STRING,
CHANGED_DATE TYPE STRING,
CHANGED_BY TYPE STRING,
LOG_SYSTEM TYPE STRING,
RCP_CREADAT TYPE STRING,
RCP_CREABY TYPE STRING,
RCP_CHNGDAT TYPE STRING,
RCP_CHNGBY TYPE STRING,
RCP_LOGSYS TYPE STRING,
LINEMODE TYPE STRING,END OF T_EKKO_STR. DATA: WA_E1BP1198_SR_POP_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_E1BP1198_SR_POP_STR-MANDT sy-vline
WA_E1BP1198_SR_POP_STR-IDENTIFIER sy-vline
WA_E1BP1198_SR_POP_STR-CHANGE_NO sy-vline
WA_E1BP1198_SR_POP_STR-IDENTIFIER_MAST sy-vline
WA_E1BP1198_SR_POP_STR-IDENTIFIER_ROOT sy-vline
WA_E1BP1198_SR_POP_STR-CHANGE_NO_ROOT sy-vline
WA_E1BP1198_SR_POP_STR-NODE_NAME sy-vline
WA_E1BP1198_SR_POP_STR-NODE_TYPE sy-vline
WA_E1BP1198_SR_POP_STR-NODE_CNT sy-vline
WA_E1BP1198_SR_POP_STR-PNTXCNT sy-vline
WA_E1BP1198_SR_POP_STR-POBNR sy-vline
WA_E1BP1198_SR_POP_STR-VALFROM sy-vline
WA_E1BP1198_SR_POP_STR-VALTO sy-vline
WA_E1BP1198_SR_POP_STR-LOT_SIZE_MIN sy-vline
WA_E1BP1198_SR_POP_STR-LOT_SIZE_MAX sy-vline
WA_E1BP1198_SR_POP_STR-QUANTITY_UNIT sy-vline
WA_E1BP1198_SR_POP_STR-QUANTITY_UNIT_ISO sy-vline
WA_E1BP1198_SR_POP_STR-OTYPE sy-vline
WA_E1BP1198_SR_POP_STR-REALO sy-vline
WA_E1BP1198_SR_POP_STR-POB_TIMSTAMP sy-vline
WA_E1BP1198_SR_POP_STR-COPY_FROM sy-vline
WA_E1BP1198_SR_POP_STR-FLG_INNR sy-vline
WA_E1BP1198_SR_POP_STR-AUTH_GRP sy-vline
WA_E1BP1198_SR_POP_STR-RECORD_NO sy-vline
WA_E1BP1198_SR_POP_STR-SUBCATEGRY sy-vline
WA_E1BP1198_SR_POP_STR-SUBSTANCE sy-vline
WA_E1BP1198_SR_POP_STR-CREATED_DATE sy-vline
WA_E1BP1198_SR_POP_STR-CREATED_BY sy-vline
WA_E1BP1198_SR_POP_STR-CHANGED_DATE sy-vline
WA_E1BP1198_SR_POP_STR-CHANGED_BY sy-vline
WA_E1BP1198_SR_POP_STR-LOG_SYSTEM sy-vline
WA_E1BP1198_SR_POP_STR-RCP_CREADAT sy-vline
WA_E1BP1198_SR_POP_STR-RCP_CREABY sy-vline
WA_E1BP1198_SR_POP_STR-RCP_CHNGDAT sy-vline
WA_E1BP1198_SR_POP_STR-RCP_CHNGBY sy-vline
WA_E1BP1198_SR_POP_STR-RCP_LOGSYS sy-vline
WA_E1BP1198_SR_POP_STR-LINEMODE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.