ABAP Select data from SAP table E1BPAD1VL1 into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP E1BPAD1VL1 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to E1BPAD1VL1. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the E1BPAD1VL1 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_E1BPAD1VL1 TYPE STANDARD TABLE OF E1BPAD1VL1, WA_E1BPAD1VL1 TYPE E1BPAD1VL1, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <E1BPAD1VL1> TYPE E1BPAD1VL1. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_E1BPAD1VL1. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM E1BPAD1VL1 INTO TABLE IT_E1BPAD1VL1. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM E1BPAD1VL1 * INTO TABLE @DATA(IT_E1BPAD1VL12). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_E1BPAD1VL1 INDEX 1 INTO DATA(WA_E1BPAD1VL12). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_E1BPAD1VL1 ASSIGNING <E1BPAD1VL1>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<E1BPAD1VL1>-ADDRESS_ID = 1.
<E1BPAD1VL1>-LANGU_CR = 1.
<E1BPAD1VL1>-LANGUCRISO = 1.
<E1BPAD1VL1>-COMM_TYPE = 1.
<E1BPAD1VL1>-ADDR_GROUP = 1.
ENDLOOP. LOOP AT IT_E1BPAD1VL1 INTO WA_E1BPAD1VL1. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_E1BPAD1VL1-HOME_CITY, sy-vline,
WA_E1BPAD1VL1-HOMECITYNO, sy-vline,
WA_E1BPAD1VL1-DONT_USE_S, sy-vline,
WA_E1BPAD1VL1-DONT_USE_P, sy-vline,
WA_E1BPAD1VL1-PO_BOX_LOBBY, sy-vline,
WA_E1BPAD1VL1-DELI_SERV_TYPE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_E1BPAD1VL1 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_E1BPAD1VL1 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_E1BPAD1VL1 INTO WA_E1BPAD1VL1. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_E1BPAD1VL1_STR,
ADDRESS_ID TYPE STRING,
LANGU_CR TYPE STRING,
LANGUCRISO TYPE STRING,
COMM_TYPE TYPE STRING,
ADDR_GROUP TYPE STRING,
HOME_CITY TYPE STRING,
HOMECITYNO TYPE STRING,
DONT_USE_S TYPE STRING,
DONT_USE_P TYPE STRING,
PO_BOX_LOBBY TYPE STRING,
DELI_SERV_TYPE TYPE STRING,
DELI_SERV_NUMBER TYPE STRING,
COUNTY_CODE TYPE STRING,
COUNTY TYPE STRING,
TOWNSHIP_CODE TYPE STRING,
TOWNSHIP TYPE STRING,END OF T_EKKO_STR. DATA: WA_E1BPAD1VL1_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_E1BPAD1VL1_STR-ADDRESS_ID sy-vline
WA_E1BPAD1VL1_STR-LANGU_CR sy-vline
WA_E1BPAD1VL1_STR-LANGUCRISO sy-vline
WA_E1BPAD1VL1_STR-COMM_TYPE sy-vline
WA_E1BPAD1VL1_STR-ADDR_GROUP sy-vline
WA_E1BPAD1VL1_STR-HOME_CITY sy-vline
WA_E1BPAD1VL1_STR-HOMECITYNO sy-vline
WA_E1BPAD1VL1_STR-DONT_USE_S sy-vline
WA_E1BPAD1VL1_STR-DONT_USE_P sy-vline
WA_E1BPAD1VL1_STR-PO_BOX_LOBBY sy-vline
WA_E1BPAD1VL1_STR-DELI_SERV_TYPE sy-vline
WA_E1BPAD1VL1_STR-DELI_SERV_NUMBER sy-vline
WA_E1BPAD1VL1_STR-COUNTY_CODE sy-vline
WA_E1BPAD1VL1_STR-COUNTY sy-vline
WA_E1BPAD1VL1_STR-TOWNSHIP_CODE sy-vline
WA_E1BPAD1VL1_STR-TOWNSHIP sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.