ABAP Select data from SAP table E1BPBUSISM008_ADDR_BAS_ORG1 into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP E1BPBUSISM008_ADDR_BAS_ORG1 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to E1BPBUSISM008_ADDR_BAS_ORG1. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the E1BPBUSISM008_ADDR_BAS_ORG1 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_E1BPBUSISM008_ADDR_BAS_ORG1 TYPE STANDARD TABLE OF E1BPBUSISM008_ADDR_BAS_ORG1, WA_E1BPBUSISM008_ADDR_BAS_ORG1 TYPE E1BPBUSISM008_ADDR_BAS_ORG1, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <E1BPBUSISM008_ADDR_BAS_ORG1> TYPE E1BPBUSISM008_ADDR_BAS_ORG1. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_E1BPBUSISM008_ADDR_BAS_ORG1. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM E1BPBUSISM008_ADDR_BAS_ORG1 INTO TABLE IT_E1BPBUSISM008_ADDR_BAS_ORG1. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM E1BPBUSISM008_ADDR_BAS_ORG1 * INTO TABLE @DATA(IT_E1BPBUSISM008_ADDR_BAS_ORG12). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_E1BPBUSISM008_ADDR_BAS_ORG1 INDEX 1 INTO DATA(WA_E1BPBUSISM008_ADDR_BAS_ORG12). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_E1BPBUSISM008_ADDR_BAS_ORG1 ASSIGNING <E1BPBUSISM008_ADDR_BAS_ORG1>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<E1BPBUSISM008_ADDR_BAS_ORG1>-E_MAIL = 1.
<E1BPBUSISM008_ADDR_BAS_ORG1>-STR_SUPPL3 = 1.
<E1BPBUSISM008_ADDR_BAS_ORG1>-TITLE = 1.
<E1BPBUSISM008_ADDR_BAS_ORG1>-COUNTRYISO = 1.
<E1BPBUSISM008_ADDR_BAS_ORG1>-LANGU_ISO = 1.
ENDLOOP. LOOP AT IT_E1BPBUSISM008_ADDR_BAS_ORG1 INTO WA_E1BPBUSISM008_ADDR_BAS_ORG1. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_E1BPBUSISM008_ADDR_BAS_ORG1-BUILD_LONG, sy-vline,
WA_E1BPBUSISM008_ADDR_BAS_ORG1-REGIOGROUP, sy-vline,
WA_E1BPBUSISM008_ADDR_BAS_ORG1-HOME_CITY, sy-vline,
WA_E1BPBUSISM008_ADDR_BAS_ORG1-HOMECITYNO, sy-vline,
WA_E1BPBUSISM008_ADDR_BAS_ORG1-PCODE1_EXT, sy-vline,
WA_E1BPBUSISM008_ADDR_BAS_ORG1-PCODE2_EXT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_E1BPBUSISM008_ADDR_BAS_ORG1 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_E1BPBUSISM008_ADDR_BAS_ORG1 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_E1BPBUSISM008_ADDR_BAS_ORG1 INTO WA_E1BPBUSISM008_ADDR_BAS_ORG1. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_E1BPBUSISM008_ADDR_BAS_ORG1_STR,
E_MAIL TYPE STRING,
STR_SUPPL3 TYPE STRING,
TITLE TYPE STRING,
COUNTRYISO TYPE STRING,
LANGU_ISO TYPE STRING,
BUILD_LONG TYPE STRING,
REGIOGROUP TYPE STRING,
HOME_CITY TYPE STRING,
HOMECITYNO TYPE STRING,
PCODE1_EXT TYPE STRING,
PCODE2_EXT TYPE STRING,
PCODE3_EXT TYPE STRING,
PO_W_O_NO TYPE STRING,
PO_BOX_REG TYPE STRING,
POBOX_CTRY TYPE STRING,
PO_CTRYISO TYPE STRING,
HOMEPAGE TYPE STRING,
DONT_USE_S TYPE STRING,
DONT_USE_P TYPE STRING,
HOUSE_NO3 TYPE STRING,
LANGU_CR TYPE STRING,
LANGUCRISO TYPE STRING,END OF T_EKKO_STR. DATA: WA_E1BPBUSISM008_ADDR_BAS_ORG1_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_E1BPBUSISM008_ADDR_BAS_ORG1_STR-E_MAIL sy-vline
WA_E1BPBUSISM008_ADDR_BAS_ORG1_STR-STR_SUPPL3 sy-vline
WA_E1BPBUSISM008_ADDR_BAS_ORG1_STR-TITLE sy-vline
WA_E1BPBUSISM008_ADDR_BAS_ORG1_STR-COUNTRYISO sy-vline
WA_E1BPBUSISM008_ADDR_BAS_ORG1_STR-LANGU_ISO sy-vline
WA_E1BPBUSISM008_ADDR_BAS_ORG1_STR-BUILD_LONG sy-vline
WA_E1BPBUSISM008_ADDR_BAS_ORG1_STR-REGIOGROUP sy-vline
WA_E1BPBUSISM008_ADDR_BAS_ORG1_STR-HOME_CITY sy-vline
WA_E1BPBUSISM008_ADDR_BAS_ORG1_STR-HOMECITYNO sy-vline
WA_E1BPBUSISM008_ADDR_BAS_ORG1_STR-PCODE1_EXT sy-vline
WA_E1BPBUSISM008_ADDR_BAS_ORG1_STR-PCODE2_EXT sy-vline
WA_E1BPBUSISM008_ADDR_BAS_ORG1_STR-PCODE3_EXT sy-vline
WA_E1BPBUSISM008_ADDR_BAS_ORG1_STR-PO_W_O_NO sy-vline
WA_E1BPBUSISM008_ADDR_BAS_ORG1_STR-PO_BOX_REG sy-vline
WA_E1BPBUSISM008_ADDR_BAS_ORG1_STR-POBOX_CTRY sy-vline
WA_E1BPBUSISM008_ADDR_BAS_ORG1_STR-PO_CTRYISO sy-vline
WA_E1BPBUSISM008_ADDR_BAS_ORG1_STR-HOMEPAGE sy-vline
WA_E1BPBUSISM008_ADDR_BAS_ORG1_STR-DONT_USE_S sy-vline
WA_E1BPBUSISM008_ADDR_BAS_ORG1_STR-DONT_USE_P sy-vline
WA_E1BPBUSISM008_ADDR_BAS_ORG1_STR-HOUSE_NO3 sy-vline
WA_E1BPBUSISM008_ADDR_BAS_ORG1_STR-LANGU_CR sy-vline
WA_E1BPBUSISM008_ADDR_BAS_ORG1_STR-LANGUCRISO sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.