ABAP Select data from SAP table E1BPMEOUTSCALEVALUE into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP E1BPMEOUTSCALEVALUE table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to E1BPMEOUTSCALEVALUE. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the E1BPMEOUTSCALEVALUE table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_E1BPMEOUTSCALEVALUE TYPE STANDARD TABLE OF E1BPMEOUTSCALEVALUE, WA_E1BPMEOUTSCALEVALUE TYPE E1BPMEOUTSCALEVALUE, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <E1BPMEOUTSCALEVALUE> TYPE E1BPMEOUTSCALEVALUE. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_E1BPMEOUTSCALEVALUE. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM E1BPMEOUTSCALEVALUE INTO TABLE IT_E1BPMEOUTSCALEVALUE. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM E1BPMEOUTSCALEVALUE * INTO TABLE @DATA(IT_E1BPMEOUTSCALEVALUE2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_E1BPMEOUTSCALEVALUE INDEX 1 INTO DATA(WA_E1BPMEOUTSCALEVALUE2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_E1BPMEOUTSCALEVALUE ASSIGNING <E1BPMEOUTSCALEVALUE>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<E1BPMEOUTSCALEVALUE>-SERIAL_NO = 1.
<E1BPMEOUTSCALEVALUE>-COND_COUNT = 1.
<E1BPMEOUTSCALEVALUE>-LINE_NO = 1.
<E1BPMEOUTSCALEVALUE>-SCALE_BASE_VALUE = 1.
<E1BPMEOUTSCALEVALUE>-COND_VALUE = 1.
ENDLOOP. LOOP AT IT_E1BPMEOUTSCALEVALUE INTO WA_E1BPMEOUTSCALEVALUE. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, ENDLOOP. *Add any further fields from structure WA_E1BPMEOUTSCALEVALUE you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_E1BPMEOUTSCALEVALUE TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_E1BPMEOUTSCALEVALUE INTO WA_E1BPMEOUTSCALEVALUE. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_E1BPMEOUTSCALEVALUE_STR,
SERIAL_NO TYPE STRING,
COND_COUNT TYPE STRING,
LINE_NO TYPE STRING,
SCALE_BASE_VALUE TYPE STRING,
COND_VALUE TYPE STRING,END OF T_EKKO_STR. DATA: WA_E1BPMEOUTSCALEVALUE_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_E1BPMEOUTSCALEVALUE_STR-SERIAL_NO sy-vline
WA_E1BPMEOUTSCALEVALUE_STR-COND_COUNT sy-vline
WA_E1BPMEOUTSCALEVALUE_STR-LINE_NO sy-vline
WA_E1BPMEOUTSCALEVALUE_STR-SCALE_BASE_VALUE sy-vline
WA_E1BPMEOUTSCALEVALUE_STR-COND_VALUE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.