ABAP Select data from SAP table E1FAGLSEC into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP E1FAGLSEC table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to E1FAGLSEC. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the E1FAGLSEC table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_E1FAGLSEC TYPE STANDARD TABLE OF E1FAGLSEC, WA_E1FAGLSEC TYPE E1FAGLSEC, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <E1FAGLSEC> TYPE E1FAGLSEC. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_E1FAGLSEC. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM E1FAGLSEC INTO TABLE IT_E1FAGLSEC. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM E1FAGLSEC * INTO TABLE @DATA(IT_E1FAGLSEC2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_E1FAGLSEC INDEX 1 INTO DATA(WA_E1FAGLSEC2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_E1FAGLSEC ASSIGNING <E1FAGLSEC>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<E1FAGLSEC>-BUZEI = 1.
<E1FAGLSEC>-NAME1 = 1.
<E1FAGLSEC>-NAME2 = 1.
<E1FAGLSEC>-NAME3 = 1.
<E1FAGLSEC>-NAME4 = 1.
ENDLOOP. LOOP AT IT_E1FAGLSEC INTO WA_E1FAGLSEC. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_E1FAGLSEC-PSTLZ, sy-vline,
WA_E1FAGLSEC-ORT01, sy-vline,
WA_E1FAGLSEC-LAND1, sy-vline,
WA_E1FAGLSEC-STRAS, sy-vline,
WA_E1FAGLSEC-PFACH, sy-vline,
WA_E1FAGLSEC-PSTL2, sy-vline.
ENDLOOP. *Add any further fields from structure WA_E1FAGLSEC you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_E1FAGLSEC TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_E1FAGLSEC INTO WA_E1FAGLSEC. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_E1FAGLSEC_STR,
BUZEI TYPE STRING,
NAME1 TYPE STRING,
NAME2 TYPE STRING,
NAME3 TYPE STRING,
NAME4 TYPE STRING,
PSTLZ TYPE STRING,
ORT01 TYPE STRING,
LAND1 TYPE STRING,
STRAS TYPE STRING,
PFACH TYPE STRING,
PSTL2 TYPE STRING,
PSKTO TYPE STRING,
BANKN TYPE STRING,
BANKL TYPE STRING,
BANKS TYPE STRING,
STCD1 TYPE STRING,
STCD2 TYPE STRING,
STKZU TYPE STRING,
STKZA TYPE STRING,
REGIO TYPE STRING,
BKONT TYPE STRING,
DTAWS TYPE STRING,
DTAMS TYPE STRING,
SPRAS TYPE STRING,
SPRAS_ISO TYPE STRING,
XCPDK TYPE STRING,
EMPFG TYPE STRING,
FITYP TYPE STRING,
STCDT TYPE STRING,
STKZN TYPE STRING,
STCD3 TYPE STRING,
STCD4 TYPE STRING,
BKREF TYPE STRING,
J_1KFREPRE TYPE STRING,
J_1KFTBUS TYPE STRING,
J_1KFTIND TYPE STRING,
ANRED TYPE STRING,
ADRNR TYPE STRING,
RESERVE TYPE STRING,END OF T_EKKO_STR. DATA: WA_E1FAGLSEC_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_E1FAGLSEC_STR-BUZEI sy-vline
WA_E1FAGLSEC_STR-NAME1 sy-vline
WA_E1FAGLSEC_STR-NAME2 sy-vline
WA_E1FAGLSEC_STR-NAME3 sy-vline
WA_E1FAGLSEC_STR-NAME4 sy-vline
WA_E1FAGLSEC_STR-PSTLZ sy-vline
WA_E1FAGLSEC_STR-ORT01 sy-vline
WA_E1FAGLSEC_STR-LAND1 sy-vline
WA_E1FAGLSEC_STR-STRAS sy-vline
WA_E1FAGLSEC_STR-PFACH sy-vline
WA_E1FAGLSEC_STR-PSTL2 sy-vline
WA_E1FAGLSEC_STR-PSKTO sy-vline
WA_E1FAGLSEC_STR-BANKN sy-vline
WA_E1FAGLSEC_STR-BANKL sy-vline
WA_E1FAGLSEC_STR-BANKS sy-vline
WA_E1FAGLSEC_STR-STCD1 sy-vline
WA_E1FAGLSEC_STR-STCD2 sy-vline
WA_E1FAGLSEC_STR-STKZU sy-vline
WA_E1FAGLSEC_STR-STKZA sy-vline
WA_E1FAGLSEC_STR-REGIO sy-vline
WA_E1FAGLSEC_STR-BKONT sy-vline
WA_E1FAGLSEC_STR-DTAWS sy-vline
WA_E1FAGLSEC_STR-DTAMS sy-vline
WA_E1FAGLSEC_STR-SPRAS sy-vline
WA_E1FAGLSEC_STR-SPRAS_ISO sy-vline
WA_E1FAGLSEC_STR-XCPDK sy-vline
WA_E1FAGLSEC_STR-EMPFG sy-vline
WA_E1FAGLSEC_STR-FITYP sy-vline
WA_E1FAGLSEC_STR-STCDT sy-vline
WA_E1FAGLSEC_STR-STKZN sy-vline
WA_E1FAGLSEC_STR-STCD3 sy-vline
WA_E1FAGLSEC_STR-STCD4 sy-vline
WA_E1FAGLSEC_STR-BKREF sy-vline
WA_E1FAGLSEC_STR-J_1KFREPRE sy-vline
WA_E1FAGLSEC_STR-J_1KFTBUS sy-vline
WA_E1FAGLSEC_STR-J_1KFTIND sy-vline
WA_E1FAGLSEC_STR-ANRED sy-vline
WA_E1FAGLSEC_STR-ADRNR sy-vline
WA_E1FAGLSEC_STR-RESERVE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.