ABAP Select data from SAP table E1KEKO into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP E1KEKO table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to E1KEKO. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the E1KEKO table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_E1KEKO TYPE STANDARD TABLE OF E1KEKO, WA_E1KEKO TYPE E1KEKO, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <E1KEKO> TYPE E1KEKO. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_E1KEKO. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM E1KEKO INTO TABLE IT_E1KEKO. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM E1KEKO * INTO TABLE @DATA(IT_E1KEKO2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_E1KEKO INDEX 1 INTO DATA(WA_E1KEKO2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_E1KEKO ASSIGNING <E1KEKO>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<E1KEKO>-MANDT = 1.
<E1KEKO>-BZOBJ = 1.
<E1KEKO>-KALNR = 1.
<E1KEKO>-KALKA = 1.
<E1KEKO>-KADKY = 1.
ENDLOOP. LOOP AT IT_E1KEKO INTO WA_E1KEKO. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_E1KEKO-TVERS, sy-vline,
WA_E1KEKO-BWVAR, sy-vline,
WA_E1KEKO-KKZMA, sy-vline,
WA_E1KEKO-MATNR, sy-vline,
WA_E1KEKO-WERKS, sy-vline,
WA_E1KEKO-BWKEY, sy-vline.
ENDLOOP. *Add any further fields from structure WA_E1KEKO you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_E1KEKO TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_E1KEKO INTO WA_E1KEKO. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit MATN5, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN5_OUTPUT' EXPORTING input = WA_E1KEKO-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_E1KEKO-MATNR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit NUMCV, internal->external for field STNUM CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_E1KEKO-STNUM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_E1KEKO-STNUM.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field STALT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_E1KEKO-STALT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_E1KEKO-STALT.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field PLNNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_E1KEKO-PLNNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_E1KEKO-PLNNR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field PLNAL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_E1KEKO-PLNAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_E1KEKO-PLNAL.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_E1KEKO_STR,
MANDT TYPE STRING,
BZOBJ TYPE STRING,
KALNR TYPE STRING,
KALKA TYPE STRING,
KADKY TYPE STRING,
TVERS TYPE STRING,
BWVAR TYPE STRING,
KKZMA TYPE STRING,
MATNR TYPE STRING,
WERKS TYPE STRING,
BWKEY TYPE STRING,
BWTAR TYPE STRING,
KOKRS TYPE STRING,
KADAT TYPE STRING,
BIDAT TYPE STRING,
KADAM TYPE STRING,
BIDAM TYPE STRING,
BWDAT TYPE STRING,
ALDAT TYPE STRING,
BEDAT TYPE STRING,
STNUM TYPE STRING,
STLAN TYPE STRING,
STALT TYPE STRING,
STCNT TYPE STRING,
PLNNR TYPE STRING,
PLNTY TYPE STRING,
PLNAL TYPE STRING,
PLNCT TYPE STRING,
LOEKZ TYPE STRING,
LOSGR TYPE STRING,
MEINS TYPE STRING,
FEH_ANZ TYPE STRING,
FEH_K_ANZ TYPE STRING,
FEH_STA TYPE STRING,
FREIG TYPE STRING,
MKALK TYPE STRING,
SOBES TYPE STRING,
SOWRK TYPE STRING,
SOBWT TYPE STRING,
KALSM TYPE STRING,
AUFZA TYPE STRING,
BWSMR TYPE STRING,
KLVAR TYPE STRING,
KOSGR TYPE STRING,
ZSCHL TYPE STRING,
POPER TYPE STRING,
BDATJ TYPE STRING,
STKOZ TYPE STRING,
ZAEHL TYPE STRING,
OCS_COUNT TYPE STRING,
ERZKA TYPE STRING,
LOSAU TYPE STRING,
SAPRL TYPE STRING,
KZROH TYPE STRING,
CUOBJ TYPE STRING,
CUOBJID TYPE STRING,
TYPE TYPE STRING,
VORMDAT TYPE STRING,
VORMUSR TYPE STRING,
FREIDAT TYPE STRING,
FREIUSR TYPE STRING,
UEBID TYPE STRING,
PROZESS TYPE STRING,
CSPLIT TYPE STRING,
WAERS TYPE STRING,
WAERO TYPE STRING,
UMRDAT TYPE STRING,
BUKRS TYPE STRING,
KALKL TYPE STRING,
TRANS_SUB_KEPH_NO TYPE STRING,
KZKUP TYPE STRING,
ZIFFR TYPE STRING,
SUMZIFFR TYPE STRING,
SBDKZ TYPE STRING,
MLMAA TYPE STRING,
BESKZ TYPE STRING,
DISST TYPE STRING,
PART_VRSN TYPE STRING,
ELEHK TYPE STRING,
ELEHKNS TYPE STRING,
HWAER TYPE STRING,
FWAER_KPF TYPE STRING,
TRANS_PATNR_KOKRS TYPE STRING,
TRANS_PATNR_BUKRS TYPE STRING,
TRANS_PATNR_PRCTR TYPE STRING,
TRANS_PATNR_GSBER TYPE STRING,
TRANS_PATNR_WERKS TYPE STRING,
PRCTR TYPE STRING,
GSBER TYPE STRING,
MATNR_EXTERNAL TYPE STRING,
MATNR_VERSION TYPE STRING,
MATNR_GUID TYPE STRING,
PROZESS_EXTERNAL TYPE STRING,
PROZESS_VERSION TYPE STRING,
PROZESS_GUID TYPE STRING,
TYPE_EXTERNAL TYPE STRING,
TYPE_VERSION TYPE STRING,
TYPE_GUID TYPE STRING,
MATNR_LONG TYPE STRING,
TYPE_LONG TYPE STRING,
PROZESS_LONG TYPE STRING,END OF T_EKKO_STR. DATA: WA_E1KEKO_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_E1KEKO_STR-MANDT sy-vline
WA_E1KEKO_STR-BZOBJ sy-vline
WA_E1KEKO_STR-KALNR sy-vline
WA_E1KEKO_STR-KALKA sy-vline
WA_E1KEKO_STR-KADKY sy-vline
WA_E1KEKO_STR-TVERS sy-vline
WA_E1KEKO_STR-BWVAR sy-vline
WA_E1KEKO_STR-KKZMA sy-vline
WA_E1KEKO_STR-MATNR sy-vline
WA_E1KEKO_STR-WERKS sy-vline
WA_E1KEKO_STR-BWKEY sy-vline
WA_E1KEKO_STR-BWTAR sy-vline
WA_E1KEKO_STR-KOKRS sy-vline
WA_E1KEKO_STR-KADAT sy-vline
WA_E1KEKO_STR-BIDAT sy-vline
WA_E1KEKO_STR-KADAM sy-vline
WA_E1KEKO_STR-BIDAM sy-vline
WA_E1KEKO_STR-BWDAT sy-vline
WA_E1KEKO_STR-ALDAT sy-vline
WA_E1KEKO_STR-BEDAT sy-vline
WA_E1KEKO_STR-STNUM sy-vline
WA_E1KEKO_STR-STLAN sy-vline
WA_E1KEKO_STR-STALT sy-vline
WA_E1KEKO_STR-STCNT sy-vline
WA_E1KEKO_STR-PLNNR sy-vline
WA_E1KEKO_STR-PLNTY sy-vline
WA_E1KEKO_STR-PLNAL sy-vline
WA_E1KEKO_STR-PLNCT sy-vline
WA_E1KEKO_STR-LOEKZ sy-vline
WA_E1KEKO_STR-LOSGR sy-vline
WA_E1KEKO_STR-MEINS sy-vline
WA_E1KEKO_STR-FEH_ANZ sy-vline
WA_E1KEKO_STR-FEH_K_ANZ sy-vline
WA_E1KEKO_STR-FEH_STA sy-vline
WA_E1KEKO_STR-FREIG sy-vline
WA_E1KEKO_STR-MKALK sy-vline
WA_E1KEKO_STR-SOBES sy-vline
WA_E1KEKO_STR-SOWRK sy-vline
WA_E1KEKO_STR-SOBWT sy-vline
WA_E1KEKO_STR-KALSM sy-vline
WA_E1KEKO_STR-AUFZA sy-vline
WA_E1KEKO_STR-BWSMR sy-vline
WA_E1KEKO_STR-KLVAR sy-vline
WA_E1KEKO_STR-KOSGR sy-vline
WA_E1KEKO_STR-ZSCHL sy-vline
WA_E1KEKO_STR-POPER sy-vline
WA_E1KEKO_STR-BDATJ sy-vline
WA_E1KEKO_STR-STKOZ sy-vline
WA_E1KEKO_STR-ZAEHL sy-vline
WA_E1KEKO_STR-OCS_COUNT sy-vline
WA_E1KEKO_STR-ERZKA sy-vline
WA_E1KEKO_STR-LOSAU sy-vline
WA_E1KEKO_STR-SAPRL sy-vline
WA_E1KEKO_STR-KZROH sy-vline
WA_E1KEKO_STR-CUOBJ sy-vline
WA_E1KEKO_STR-CUOBJID sy-vline
WA_E1KEKO_STR-TYPE sy-vline
WA_E1KEKO_STR-VORMDAT sy-vline
WA_E1KEKO_STR-VORMUSR sy-vline
WA_E1KEKO_STR-FREIDAT sy-vline
WA_E1KEKO_STR-FREIUSR sy-vline
WA_E1KEKO_STR-UEBID sy-vline
WA_E1KEKO_STR-PROZESS sy-vline
WA_E1KEKO_STR-CSPLIT sy-vline
WA_E1KEKO_STR-WAERS sy-vline
WA_E1KEKO_STR-WAERO sy-vline
WA_E1KEKO_STR-UMRDAT sy-vline
WA_E1KEKO_STR-BUKRS sy-vline
WA_E1KEKO_STR-KALKL sy-vline
WA_E1KEKO_STR-TRANS_SUB_KEPH_NO sy-vline
WA_E1KEKO_STR-KZKUP sy-vline
WA_E1KEKO_STR-ZIFFR sy-vline
WA_E1KEKO_STR-SUMZIFFR sy-vline
WA_E1KEKO_STR-SBDKZ sy-vline
WA_E1KEKO_STR-MLMAA sy-vline
WA_E1KEKO_STR-BESKZ sy-vline
WA_E1KEKO_STR-DISST sy-vline
WA_E1KEKO_STR-PART_VRSN sy-vline
WA_E1KEKO_STR-ELEHK sy-vline
WA_E1KEKO_STR-ELEHKNS sy-vline
WA_E1KEKO_STR-HWAER sy-vline
WA_E1KEKO_STR-FWAER_KPF sy-vline
WA_E1KEKO_STR-TRANS_PATNR_KOKRS sy-vline
WA_E1KEKO_STR-TRANS_PATNR_BUKRS sy-vline
WA_E1KEKO_STR-TRANS_PATNR_PRCTR sy-vline
WA_E1KEKO_STR-TRANS_PATNR_GSBER sy-vline
WA_E1KEKO_STR-TRANS_PATNR_WERKS sy-vline
WA_E1KEKO_STR-PRCTR sy-vline
WA_E1KEKO_STR-GSBER sy-vline
WA_E1KEKO_STR-MATNR_EXTERNAL sy-vline
WA_E1KEKO_STR-MATNR_VERSION sy-vline
WA_E1KEKO_STR-MATNR_GUID sy-vline
WA_E1KEKO_STR-PROZESS_EXTERNAL sy-vline
WA_E1KEKO_STR-PROZESS_VERSION sy-vline
WA_E1KEKO_STR-PROZESS_GUID sy-vline
WA_E1KEKO_STR-TYPE_EXTERNAL sy-vline
WA_E1KEKO_STR-TYPE_VERSION sy-vline
WA_E1KEKO_STR-TYPE_GUID sy-vline
WA_E1KEKO_STR-MATNR_LONG sy-vline
WA_E1KEKO_STR-TYPE_LONG sy-vline
WA_E1KEKO_STR-PROZESS_LONG sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.