ABAP Select data from SAP table E1OIJTKTSI into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP E1OIJTKTSI table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to E1OIJTKTSI. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the E1OIJTKTSI table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_E1OIJTKTSI TYPE STANDARD TABLE OF E1OIJTKTSI,
      WA_E1OIJTKTSI TYPE E1OIJTKTSI,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <E1OIJTKTSI> TYPE E1OIJTKTSI.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_E1OIJTKTSI.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM E1OIJTKTSI
  INTO TABLE IT_E1OIJTKTSI.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM E1OIJTKTSI
*  INTO TABLE @DATA(IT_E1OIJTKTSI2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_E1OIJTKTSI INDEX 1 INTO DATA(WA_E1OIJTKTSI2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_E1OIJTKTSI ASSIGNING <E1OIJTKTSI>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<E1OIJTKTSI>-NOMTK = 1.
<E1OIJTKTSI>-NOMIT = 1.
<E1OIJTKTSI>-SUBITEM = 1.
<E1OIJTKTSI>-NOMAPP = 1.
<E1OIJTKTSI>-MATNR_I = 1.
ENDLOOP.

LOOP AT IT_E1OIJTKTSI INTO WA_E1OIJTKTSI.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_E1OIJTKTSI-SUBITM_QTY, sy-vline,
WA_E1OIJTKTSI-SUBITM_UOM, sy-vline,
WA_E1OIJTKTSI-CAPACITY, sy-vline,
WA_E1OIJTKTSI-PL_DATE, sy-vline,
WA_E1OIJTKTSI-PL_TIME, sy-vline,
WA_E1OIJTKTSI-SCHED_TST, sy-vline.
ENDLOOP. *Add any further fields from structure WA_E1OIJTKTSI you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_E1OIJTKTSI TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_E1OIJTKTSI INTO WA_E1OIJTKTSI. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_E1OIJTKTSI_STR,
NOMTK TYPE STRING,
NOMIT TYPE STRING,
SUBITEM TYPE STRING,
NOMAPP TYPE STRING,
MATNR_I TYPE STRING,
SUBITM_QTY TYPE STRING,
SUBITM_UOM TYPE STRING,
CAPACITY TYPE STRING,
PL_DATE TYPE STRING,
PL_TIME TYPE STRING,
SCHED_TST TYPE STRING,
SUBITM_ACTQTY TYPE STRING,
SUBITM_ACTUOM TYPE STRING,
TICKET_KEY TYPE STRING,
ACTUAL_TST TYPE STRING,
ACT_TIME TYPE STRING,
ACT_DATE TYPE STRING,
TICKET_ITEM TYPE STRING,
TICKET_VERSION TYPE STRING,
TICKET_PURPOSE TYPE STRING,
STATUS TYPE STRING,
DELIND TYPE STRING,
RAILCARID TYPE STRING,
RAIL_SPLIT_SEQ TYPE STRING,
RAILCAR_TYPE TYPE STRING,
TARIFF TYPE STRING,
CURRENCY TYPE STRING,
DOCIND_R TYPE STRING,
DOCNR_R TYPE STRING,
DOCITM_R TYPE STRING,
ACTUALQTY_PAR TYPE STRING,
ACTUALUOM_PAR TYPE STRING,
MATNR_I_LONG TYPE STRING,END OF T_EKKO_STR. DATA: WA_E1OIJTKTSI_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_E1OIJTKTSI_STR-NOMTK sy-vline
WA_E1OIJTKTSI_STR-NOMIT sy-vline
WA_E1OIJTKTSI_STR-SUBITEM sy-vline
WA_E1OIJTKTSI_STR-NOMAPP sy-vline
WA_E1OIJTKTSI_STR-MATNR_I sy-vline
WA_E1OIJTKTSI_STR-SUBITM_QTY sy-vline
WA_E1OIJTKTSI_STR-SUBITM_UOM sy-vline
WA_E1OIJTKTSI_STR-CAPACITY sy-vline
WA_E1OIJTKTSI_STR-PL_DATE sy-vline
WA_E1OIJTKTSI_STR-PL_TIME sy-vline
WA_E1OIJTKTSI_STR-SCHED_TST sy-vline
WA_E1OIJTKTSI_STR-SUBITM_ACTQTY sy-vline
WA_E1OIJTKTSI_STR-SUBITM_ACTUOM sy-vline
WA_E1OIJTKTSI_STR-TICKET_KEY sy-vline
WA_E1OIJTKTSI_STR-ACTUAL_TST sy-vline
WA_E1OIJTKTSI_STR-ACT_TIME sy-vline
WA_E1OIJTKTSI_STR-ACT_DATE sy-vline
WA_E1OIJTKTSI_STR-TICKET_ITEM sy-vline
WA_E1OIJTKTSI_STR-TICKET_VERSION sy-vline
WA_E1OIJTKTSI_STR-TICKET_PURPOSE sy-vline
WA_E1OIJTKTSI_STR-STATUS sy-vline
WA_E1OIJTKTSI_STR-DELIND sy-vline
WA_E1OIJTKTSI_STR-RAILCARID sy-vline
WA_E1OIJTKTSI_STR-RAIL_SPLIT_SEQ sy-vline
WA_E1OIJTKTSI_STR-RAILCAR_TYPE sy-vline
WA_E1OIJTKTSI_STR-TARIFF sy-vline
WA_E1OIJTKTSI_STR-CURRENCY sy-vline
WA_E1OIJTKTSI_STR-DOCIND_R sy-vline
WA_E1OIJTKTSI_STR-DOCNR_R sy-vline
WA_E1OIJTKTSI_STR-DOCITM_R sy-vline
WA_E1OIJTKTSI_STR-ACTUALQTY_PAR sy-vline
WA_E1OIJTKTSI_STR-ACTUALUOM_PAR sy-vline
WA_E1OIJTKTSI_STR-MATNR_I_LONG sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.