ABAP Select data from SAP table E1PADPM into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP E1PADPM table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to E1PADPM. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the E1PADPM table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_E1PADPM TYPE STANDARD TABLE OF E1PADPM, WA_E1PADPM TYPE E1PADPM, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <E1PADPM> TYPE E1PADPM. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_E1PADPM. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM E1PADPM INTO TABLE IT_E1PADPM. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM E1PADPM * INTO TABLE @DATA(IT_E1PADPM2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_E1PADPM INDEX 1 INTO DATA(WA_E1PADPM2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_E1PADPM ASSIGNING <E1PADPM>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<E1PADPM>-MANDT = 1.
<E1PADPM>-PLVAR = 1.
<E1PADPM>-OTYPE = 1.
<E1PADPM>-OBJID = 1.
<E1PADPM>-INFTY = 1.
ENDLOOP. LOOP AT IT_E1PADPM INTO WA_E1PADPM. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_E1PADPM-RSIGN, sy-vline,
WA_E1PADPM-RELAT, sy-vline,
WA_E1PADPM-ISTAT, sy-vline,
WA_E1PADPM-PRIOX, sy-vline,
WA_E1PADPM-BEGDA, sy-vline,
WA_E1PADPM-ENDDA, sy-vline.
ENDLOOP. *Add any further fields from structure WA_E1PADPM you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_E1PADPM TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_E1PADPM INTO WA_E1PADPM. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_E1PADPM_STR,
MANDT TYPE STRING,
PLVAR TYPE STRING,
OTYPE TYPE STRING,
OBJID TYPE STRING,
INFTY TYPE STRING,
RSIGN TYPE STRING,
RELAT TYPE STRING,
ISTAT TYPE STRING,
PRIOX TYPE STRING,
BEGDA TYPE STRING,
ENDDA TYPE STRING,
VARYF TYPE STRING,
SEQNR TYPE STRING,
AEDTM TYPE STRING,
UNAME TYPE STRING,
REASN TYPE STRING,
HISTO TYPE STRING,
ITXNR TYPE STRING,
SCLAS TYPE STRING,
SOBID TYPE STRING,
PROZT TYPE STRING,
BUTGR TYPE STRING,
KRESV TYPE STRING,
BETRG TYPE STRING,
CURCY TYPE STRING,
FREQU TYPE STRING,
AMNT TYPE STRING,
BUGRU TYPE STRING,
WKAVG TYPE STRING,
MOLGA TYPE STRING,
KATZU TYPE STRING,
ARTZU TYPE STRING,
AUSART TYPE STRING,
PERNR TYPE STRING,
KINTE TYPE STRING,
OBJ_TYPE TYPE STRING,
OBJ_SYS TYPE STRING,
OBJ_KEY TYPE STRING,
OBJ_POS TYPE STRING,
OBJ_TYPE_P TYPE STRING,
OBJ_KEY_P TYPE STRING,
OBJ_POS_P TYPE STRING,END OF T_EKKO_STR. DATA: WA_E1PADPM_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_E1PADPM_STR-MANDT sy-vline
WA_E1PADPM_STR-PLVAR sy-vline
WA_E1PADPM_STR-OTYPE sy-vline
WA_E1PADPM_STR-OBJID sy-vline
WA_E1PADPM_STR-INFTY sy-vline
WA_E1PADPM_STR-RSIGN sy-vline
WA_E1PADPM_STR-RELAT sy-vline
WA_E1PADPM_STR-ISTAT sy-vline
WA_E1PADPM_STR-PRIOX sy-vline
WA_E1PADPM_STR-BEGDA sy-vline
WA_E1PADPM_STR-ENDDA sy-vline
WA_E1PADPM_STR-VARYF sy-vline
WA_E1PADPM_STR-SEQNR sy-vline
WA_E1PADPM_STR-AEDTM sy-vline
WA_E1PADPM_STR-UNAME sy-vline
WA_E1PADPM_STR-REASN sy-vline
WA_E1PADPM_STR-HISTO sy-vline
WA_E1PADPM_STR-ITXNR sy-vline
WA_E1PADPM_STR-SCLAS sy-vline
WA_E1PADPM_STR-SOBID sy-vline
WA_E1PADPM_STR-PROZT sy-vline
WA_E1PADPM_STR-BUTGR sy-vline
WA_E1PADPM_STR-KRESV sy-vline
WA_E1PADPM_STR-BETRG sy-vline
WA_E1PADPM_STR-CURCY sy-vline
WA_E1PADPM_STR-FREQU sy-vline
WA_E1PADPM_STR-AMNT sy-vline
WA_E1PADPM_STR-BUGRU sy-vline
WA_E1PADPM_STR-WKAVG sy-vline
WA_E1PADPM_STR-MOLGA sy-vline
WA_E1PADPM_STR-KATZU sy-vline
WA_E1PADPM_STR-ARTZU sy-vline
WA_E1PADPM_STR-AUSART sy-vline
WA_E1PADPM_STR-PERNR sy-vline
WA_E1PADPM_STR-KINTE sy-vline
WA_E1PADPM_STR-OBJ_TYPE sy-vline
WA_E1PADPM_STR-OBJ_SYS sy-vline
WA_E1PADPM_STR-OBJ_KEY sy-vline
WA_E1PADPM_STR-OBJ_POS sy-vline
WA_E1PADPM_STR-OBJ_TYPE_P sy-vline
WA_E1PADPM_STR-OBJ_KEY_P sy-vline
WA_E1PADPM_STR-OBJ_POS_P sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.