ABAP Select data from SAP table E1Q0526 into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP E1Q0526 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to E1Q0526. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the E1Q0526 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_E1Q0526 TYPE STANDARD TABLE OF E1Q0526, WA_E1Q0526 TYPE E1Q0526, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <E1Q0526> TYPE E1Q0526. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_E1Q0526. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM E1Q0526 INTO TABLE IT_E1Q0526. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM E1Q0526 * INTO TABLE @DATA(IT_E1Q05262). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_E1Q0526 INDEX 1 INTO DATA(WA_E1Q05262). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_E1Q0526 ASSIGNING <E1Q0526>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<E1Q0526>-PERNR = 1.
<E1Q0526>-INFTY = 1.
<E1Q0526>-SUBTY = 1.
<E1Q0526>-OBJPS = 1.
<E1Q0526>-SPRPS = 1.
ENDLOOP. LOOP AT IT_E1Q0526 INTO WA_E1Q0526. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_E1Q0526-ENDDA, sy-vline,
WA_E1Q0526-BEGDA, sy-vline,
WA_E1Q0526-SEQNR, sy-vline,
WA_E1Q0526-ANV50, sy-vline,
WA_E1Q0526-ANB50, sy-vline,
WA_E1Q0526-ANV60, sy-vline.
ENDLOOP. *Add any further fields from structure WA_E1Q0526 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_E1Q0526 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_E1Q0526 INTO WA_E1Q0526. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_E1Q0526_STR,
PERNR TYPE STRING,
INFTY TYPE STRING,
SUBTY TYPE STRING,
OBJPS TYPE STRING,
SPRPS TYPE STRING,
ENDDA TYPE STRING,
BEGDA TYPE STRING,
SEQNR TYPE STRING,
ANV50 TYPE STRING,
ANB50 TYPE STRING,
ANV60 TYPE STRING,
ANB60 TYPE STRING,
EIN50 TYPE STRING,
EIN60 TYPE STRING,
UNV50 TYPE STRING,
UNB50 TYPE STRING,
UNV60 TYPE STRING,
UNB60 TYPE STRING,
UNV70 TYPE STRING,
UNB70 TYPE STRING,
UNV80 TYPE STRING,
UNB80 TYPE STRING,
GRPVL TYPE STRING,
DGNA01 TYPE STRING,
DTEL01 TYPE STRING,
AVER2 TYPE STRING,
IBAN TYPE STRING,
TITL2 TYPE STRING,
SBGB0 TYPE STRING,
LABTG0 TYPE STRING,
PLZL1 TYPE STRING,
WORT1 TYPE STRING,
STRA1 TYPE STRING,
BIC0 TYPE STRING,
APF01 TYPE STRING,
APF02 TYPE STRING,
APF03 TYPE STRING,
APF04 TYPE STRING,
APF05 TYPE STRING,
APF06 TYPE STRING,
APF07 TYPE STRING,
APF08 TYPE STRING,
APF09 TYPE STRING,
APF10 TYPE STRING,
ANV70 TYPE STRING,
ANB70 TYPE STRING,
ANV80 TYPE STRING,
ANB80 TYPE STRING,
ANV90 TYPE STRING,
ANB90 TYPE STRING,
ANVA0 TYPE STRING,
ANBA0 TYPE STRING,
GEGC0 TYPE STRING,
GEGT0 TYPE STRING,END OF T_EKKO_STR. DATA: WA_E1Q0526_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_E1Q0526_STR-PERNR sy-vline
WA_E1Q0526_STR-INFTY sy-vline
WA_E1Q0526_STR-SUBTY sy-vline
WA_E1Q0526_STR-OBJPS sy-vline
WA_E1Q0526_STR-SPRPS sy-vline
WA_E1Q0526_STR-ENDDA sy-vline
WA_E1Q0526_STR-BEGDA sy-vline
WA_E1Q0526_STR-SEQNR sy-vline
WA_E1Q0526_STR-ANV50 sy-vline
WA_E1Q0526_STR-ANB50 sy-vline
WA_E1Q0526_STR-ANV60 sy-vline
WA_E1Q0526_STR-ANB60 sy-vline
WA_E1Q0526_STR-EIN50 sy-vline
WA_E1Q0526_STR-EIN60 sy-vline
WA_E1Q0526_STR-UNV50 sy-vline
WA_E1Q0526_STR-UNB50 sy-vline
WA_E1Q0526_STR-UNV60 sy-vline
WA_E1Q0526_STR-UNB60 sy-vline
WA_E1Q0526_STR-UNV70 sy-vline
WA_E1Q0526_STR-UNB70 sy-vline
WA_E1Q0526_STR-UNV80 sy-vline
WA_E1Q0526_STR-UNB80 sy-vline
WA_E1Q0526_STR-GRPVL sy-vline
WA_E1Q0526_STR-DGNA01 sy-vline
WA_E1Q0526_STR-DTEL01 sy-vline
WA_E1Q0526_STR-AVER2 sy-vline
WA_E1Q0526_STR-IBAN sy-vline
WA_E1Q0526_STR-TITL2 sy-vline
WA_E1Q0526_STR-SBGB0 sy-vline
WA_E1Q0526_STR-LABTG0 sy-vline
WA_E1Q0526_STR-PLZL1 sy-vline
WA_E1Q0526_STR-WORT1 sy-vline
WA_E1Q0526_STR-STRA1 sy-vline
WA_E1Q0526_STR-BIC0 sy-vline
WA_E1Q0526_STR-APF01 sy-vline
WA_E1Q0526_STR-APF02 sy-vline
WA_E1Q0526_STR-APF03 sy-vline
WA_E1Q0526_STR-APF04 sy-vline
WA_E1Q0526_STR-APF05 sy-vline
WA_E1Q0526_STR-APF06 sy-vline
WA_E1Q0526_STR-APF07 sy-vline
WA_E1Q0526_STR-APF08 sy-vline
WA_E1Q0526_STR-APF09 sy-vline
WA_E1Q0526_STR-APF10 sy-vline
WA_E1Q0526_STR-ANV70 sy-vline
WA_E1Q0526_STR-ANB70 sy-vline
WA_E1Q0526_STR-ANV80 sy-vline
WA_E1Q0526_STR-ANB80 sy-vline
WA_E1Q0526_STR-ANV90 sy-vline
WA_E1Q0526_STR-ANB90 sy-vline
WA_E1Q0526_STR-ANVA0 sy-vline
WA_E1Q0526_STR-ANBA0 sy-vline
WA_E1Q0526_STR-GEGC0 sy-vline
WA_E1Q0526_STR-GEGT0 sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.