ABAP Select data from SAP table E3FIKPF into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP E3FIKPF table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to E3FIKPF. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the E3FIKPF table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_E3FIKPF TYPE STANDARD TABLE OF E3FIKPF, WA_E3FIKPF TYPE E3FIKPF, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <E3FIKPF> TYPE E3FIKPF. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_E3FIKPF. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM E3FIKPF INTO TABLE IT_E3FIKPF. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM E3FIKPF * INTO TABLE @DATA(IT_E3FIKPF2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_E3FIKPF INDEX 1 INTO DATA(WA_E3FIKPF2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_E3FIKPF ASSIGNING <E3FIKPF>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<E3FIKPF>-BUKRS = 1.
<E3FIKPF>-BELNR = 1.
<E3FIKPF>-GJAHR = 1.
<E3FIKPF>-BLART = 1.
<E3FIKPF>-BLDAT = 1.
ENDLOOP. LOOP AT IT_E3FIKPF INTO WA_E3FIKPF. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_E3FIKPF-BUDAT, sy-vline,
WA_E3FIKPF-MONAT, sy-vline,
WA_E3FIKPF-WWERT, sy-vline,
WA_E3FIKPF-USNAM, sy-vline,
WA_E3FIKPF-TCODE, sy-vline,
WA_E3FIKPF-BVORG, sy-vline.
ENDLOOP. *Add any further fields from structure WA_E3FIKPF you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_E3FIKPF TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_E3FIKPF INTO WA_E3FIKPF. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ALPHA, internal->external for field BELNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_E3FIKPF-BELNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_E3FIKPF-BELNR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit GJAHR, internal->external for field GJAHR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_E3FIKPF-GJAHR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_E3FIKPF-GJAHR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit EXCRT, internal->external for field KURSF CALL FUNCTION 'CONVERSION_EXIT_EXCRT_OUTPUT' EXPORTING input = WA_E3FIKPF-KURSF IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_E3FIKPF-KURSF.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field AWREF CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_E3FIKPF-AWREF IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_E3FIKPF-AWREF.
WRITE:/ 'New Value:', ld_input.
*Conversion exit EXCRT, internal->external for field KURS2 CALL FUNCTION 'CONVERSION_EXIT_EXCRT_OUTPUT' EXPORTING input = WA_E3FIKPF-KURS2 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_E3FIKPF-KURS2.
WRITE:/ 'New Value:', ld_input.
*Conversion exit EXCRT, internal->external for field KURS3 CALL FUNCTION 'CONVERSION_EXIT_EXCRT_OUTPUT' EXPORTING input = WA_E3FIKPF-KURS3 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_E3FIKPF-KURS3.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field AWSYS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_E3FIKPF-AWSYS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_E3FIKPF-AWSYS.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field LOTKZ CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_E3FIKPF-LOTKZ IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_E3FIKPF-LOTKZ.
WRITE:/ 'New Value:', ld_input.
*Conversion exit EXCRT, internal->external for field KURSF_M CALL FUNCTION 'CONVERSION_EXIT_EXCRT_OUTPUT' EXPORTING input = WA_E3FIKPF-KURSF_M IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_E3FIKPF-KURSF_M.
WRITE:/ 'New Value:', ld_input.
*Conversion exit EXCRT, internal->external for field KURS2_M CALL FUNCTION 'CONVERSION_EXIT_EXCRT_OUTPUT' EXPORTING input = WA_E3FIKPF-KURS2_M IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_E3FIKPF-KURS2_M.
WRITE:/ 'New Value:', ld_input.
*Conversion exit EXCRT, internal->external for field KURS3_M CALL FUNCTION 'CONVERSION_EXIT_EXCRT_OUTPUT' EXPORTING input = WA_E3FIKPF-KURS3_M IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_E3FIKPF-KURS3_M.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_E3FIKPF_STR,
BUKRS TYPE STRING,
BELNR TYPE STRING,
GJAHR TYPE STRING,
BLART TYPE STRING,
BLDAT TYPE STRING,
BUDAT TYPE STRING,
MONAT TYPE STRING,
WWERT TYPE STRING,
USNAM TYPE STRING,
TCODE TYPE STRING,
BVORG TYPE STRING,
XBLNR TYPE STRING,
BKTXT TYPE STRING,
WAERS TYPE STRING,
KURSF TYPE STRING,
GLVOR TYPE STRING,
AWTYP TYPE STRING,
AWREF TYPE STRING,
AWORG TYPE STRING,
FIKRS TYPE STRING,
HWAER TYPE STRING,
HWAE2 TYPE STRING,
HWAE3 TYPE STRING,
KURS2 TYPE STRING,
KURS3 TYPE STRING,
BASW2 TYPE STRING,
BASW3 TYPE STRING,
UMRD2 TYPE STRING,
UMRD3 TYPE STRING,
CURT2 TYPE STRING,
CURT3 TYPE STRING,
AUSBK TYPE STRING,
AWSYS TYPE STRING,
LOTKZ TYPE STRING,
BUKRS_SND TYPE STRING,
FILTER TYPE STRING,
KURSF_M TYPE STRING,
KURS2_M TYPE STRING,
KURS3_M TYPE STRING,
BSTAT TYPE STRING,
BRNCH TYPE STRING,
NUMPG TYPE STRING,
ADISC TYPE STRING,END OF T_EKKO_STR. DATA: WA_E3FIKPF_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_E3FIKPF_STR-BUKRS sy-vline
WA_E3FIKPF_STR-BELNR sy-vline
WA_E3FIKPF_STR-GJAHR sy-vline
WA_E3FIKPF_STR-BLART sy-vline
WA_E3FIKPF_STR-BLDAT sy-vline
WA_E3FIKPF_STR-BUDAT sy-vline
WA_E3FIKPF_STR-MONAT sy-vline
WA_E3FIKPF_STR-WWERT sy-vline
WA_E3FIKPF_STR-USNAM sy-vline
WA_E3FIKPF_STR-TCODE sy-vline
WA_E3FIKPF_STR-BVORG sy-vline
WA_E3FIKPF_STR-XBLNR sy-vline
WA_E3FIKPF_STR-BKTXT sy-vline
WA_E3FIKPF_STR-WAERS sy-vline
WA_E3FIKPF_STR-KURSF sy-vline
WA_E3FIKPF_STR-GLVOR sy-vline
WA_E3FIKPF_STR-AWTYP sy-vline
WA_E3FIKPF_STR-AWREF sy-vline
WA_E3FIKPF_STR-AWORG sy-vline
WA_E3FIKPF_STR-FIKRS sy-vline
WA_E3FIKPF_STR-HWAER sy-vline
WA_E3FIKPF_STR-HWAE2 sy-vline
WA_E3FIKPF_STR-HWAE3 sy-vline
WA_E3FIKPF_STR-KURS2 sy-vline
WA_E3FIKPF_STR-KURS3 sy-vline
WA_E3FIKPF_STR-BASW2 sy-vline
WA_E3FIKPF_STR-BASW3 sy-vline
WA_E3FIKPF_STR-UMRD2 sy-vline
WA_E3FIKPF_STR-UMRD3 sy-vline
WA_E3FIKPF_STR-CURT2 sy-vline
WA_E3FIKPF_STR-CURT3 sy-vline
WA_E3FIKPF_STR-AUSBK sy-vline
WA_E3FIKPF_STR-AWSYS sy-vline
WA_E3FIKPF_STR-LOTKZ sy-vline
WA_E3FIKPF_STR-BUKRS_SND sy-vline
WA_E3FIKPF_STR-FILTER sy-vline
WA_E3FIKPF_STR-KURSF_M sy-vline
WA_E3FIKPF_STR-KURS2_M sy-vline
WA_E3FIKPF_STR-KURS3_M sy-vline
WA_E3FIKPF_STR-BSTAT sy-vline
WA_E3FIKPF_STR-BRNCH sy-vline
WA_E3FIKPF_STR-NUMPG sy-vline
WA_E3FIKPF_STR-ADISC sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.