ABAP Select data from SAP table EAM_ORD_OP_MASS_GENERAL into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP EAM_ORD_OP_MASS_GENERAL table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to EAM_ORD_OP_MASS_GENERAL. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the EAM_ORD_OP_MASS_GENERAL table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_EAM_ORD_OP_MASS_GENERAL TYPE STANDARD TABLE OF EAM_ORD_OP_MASS_GENERAL,
      WA_EAM_ORD_OP_MASS_GENERAL TYPE EAM_ORD_OP_MASS_GENERAL,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <EAM_ORD_OP_MASS_GENERAL> TYPE EAM_ORD_OP_MASS_GENERAL.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_EAM_ORD_OP_MASS_GENERAL.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM EAM_ORD_OP_MASS_GENERAL
  INTO TABLE IT_EAM_ORD_OP_MASS_GENERAL.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM EAM_ORD_OP_MASS_GENERAL
*  INTO TABLE @DATA(IT_EAM_ORD_OP_MASS_GENERAL2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_EAM_ORD_OP_MASS_GENERAL INDEX 1 INTO DATA(WA_EAM_ORD_OP_MASS_GENERAL2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_EAM_ORD_OP_MASS_GENERAL ASSIGNING <EAM_ORD_OP_MASS_GENERAL>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<EAM_ORD_OP_MASS_GENERAL>-MATERIAL = 1.
<EAM_ORD_OP_MASS_GENERAL>-SERIALNUMBER = 1.
<EAM_ORD_OP_MASS_GENERAL>-UNIQUEITEMIDENTIFIER = 1.
<EAM_ORD_OP_MASS_GENERAL>-ASSEMBLY = 1.
<EAM_ORD_OP_MASS_GENERAL>-EQUIPMENT = 1.
ENDLOOP.

LOOP AT IT_EAM_ORD_OP_MASS_GENERAL INTO WA_EAM_ORD_OP_MASS_GENERAL.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_EAM_ORD_OP_MASS_GENERAL-FUNCTIONALLOCATION, sy-vline,
WA_EAM_ORD_OP_MASS_GENERAL-OPERATIONSYSTEMCONDITION, sy-vline,
WA_EAM_ORD_OP_MASS_GENERAL-OPERATIONTEXT, sy-vline,
WA_EAM_ORD_OP_MASS_GENERAL-STANDARDTEXTINTERNALID, sy-vline,
WA_EAM_ORD_OP_MASS_GENERAL-EXECFACTOR, sy-vline,
WA_EAM_ORD_OP_MASS_GENERAL-OPERATIONCONTROLPROFILE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_EAM_ORD_OP_MASS_GENERAL you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_EAM_ORD_OP_MASS_GENERAL TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_EAM_ORD_OP_MASS_GENERAL INTO WA_EAM_ORD_OP_MASS_GENERAL. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit MATN1, internal->external for field MATERIAL CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_EAM_ORD_OP_MASS_GENERAL-MATERIAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAM_ORD_OP_MASS_GENERAL-MATERIAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GERNR, internal->external for field SERIALNUMBER CALL FUNCTION 'CONVERSION_EXIT_GERNR_OUTPUT' EXPORTING input = WA_EAM_ORD_OP_MASS_GENERAL-SERIALNUMBER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAM_ORD_OP_MASS_GENERAL-SERIALNUMBER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field ASSEMBLY CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_EAM_ORD_OP_MASS_GENERAL-ASSEMBLY IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAM_ORD_OP_MASS_GENERAL-ASSEMBLY.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field EQUIPMENT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EAM_ORD_OP_MASS_GENERAL-EQUIPMENT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAM_ORD_OP_MASS_GENERAL-EQUIPMENT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TPLNR, internal->external for field FUNCTIONALLOCATION CALL FUNCTION 'CONVERSION_EXIT_TPLNR_OUTPUT' EXPORTING input = WA_EAM_ORD_OP_MASS_GENERAL-FUNCTIONALLOCATION IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAM_ORD_OP_MASS_GENERAL-FUNCTIONALLOCATION.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_EAM_ORD_OP_MASS_GENERAL_STR,
MATERIAL TYPE STRING,
SERIALNUMBER TYPE STRING,
UNIQUEITEMIDENTIFIER TYPE STRING,
ASSEMBLY TYPE STRING,
EQUIPMENT TYPE STRING,
FUNCTIONALLOCATION TYPE STRING,
OPERATIONSYSTEMCONDITION TYPE STRING,
OPERATIONTEXT TYPE STRING,
STANDARDTEXTINTERNALID TYPE STRING,
EXECFACTOR TYPE STRING,
OPERATIONCONTROLPROFILE TYPE STRING,
CHECKLISTTYPE TYPE STRING,END OF T_EKKO_STR. DATA: WA_EAM_ORD_OP_MASS_GENERAL_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_EAM_ORD_OP_MASS_GENERAL_STR-MATERIAL sy-vline
WA_EAM_ORD_OP_MASS_GENERAL_STR-SERIALNUMBER sy-vline
WA_EAM_ORD_OP_MASS_GENERAL_STR-UNIQUEITEMIDENTIFIER sy-vline
WA_EAM_ORD_OP_MASS_GENERAL_STR-ASSEMBLY sy-vline
WA_EAM_ORD_OP_MASS_GENERAL_STR-EQUIPMENT sy-vline
WA_EAM_ORD_OP_MASS_GENERAL_STR-FUNCTIONALLOCATION sy-vline
WA_EAM_ORD_OP_MASS_GENERAL_STR-OPERATIONSYSTEMCONDITION sy-vline
WA_EAM_ORD_OP_MASS_GENERAL_STR-OPERATIONTEXT sy-vline
WA_EAM_ORD_OP_MASS_GENERAL_STR-STANDARDTEXTINTERNALID sy-vline
WA_EAM_ORD_OP_MASS_GENERAL_STR-EXECFACTOR sy-vline
WA_EAM_ORD_OP_MASS_GENERAL_STR-OPERATIONCONTROLPROFILE sy-vline
WA_EAM_ORD_OP_MASS_GENERAL_STR-CHECKLISTTYPE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.