ABAP Select data from SAP table EAM_S_TL_PLMZ_UPX into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP EAM_S_TL_PLMZ_UPX table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to EAM_S_TL_PLMZ_UPX. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the EAM_S_TL_PLMZ_UPX table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_EAM_S_TL_PLMZ_UPX TYPE STANDARD TABLE OF EAM_S_TL_PLMZ_UPX, WA_EAM_S_TL_PLMZ_UPX TYPE EAM_S_TL_PLMZ_UPX, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <EAM_S_TL_PLMZ_UPX> TYPE EAM_S_TL_PLMZ_UPX. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_EAM_S_TL_PLMZ_UPX. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM EAM_S_TL_PLMZ_UPX INTO TABLE IT_EAM_S_TL_PLMZ_UPX. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM EAM_S_TL_PLMZ_UPX * INTO TABLE @DATA(IT_EAM_S_TL_PLMZ_UPX2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_EAM_S_TL_PLMZ_UPX INDEX 1 INTO DATA(WA_EAM_S_TL_PLMZ_UPX2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_EAM_S_TL_PLMZ_UPX ASSIGNING <EAM_S_TL_PLMZ_UPX>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<EAM_S_TL_PLMZ_UPX>-PLNTY = 1.
<EAM_S_TL_PLMZ_UPX>-PLNNR = 1.
<EAM_S_TL_PLMZ_UPX>-PLNAL = 1.
<EAM_S_TL_PLMZ_UPX>-PLNKN = 1.
<EAM_S_TL_PLMZ_UPX>-ZUONR = 1.
ENDLOOP. LOOP AT IT_EAM_S_TL_PLMZ_UPX INTO WA_EAM_S_TL_PLMZ_UPX. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_EAM_S_TL_PLMZ_UPX-VORNR, sy-vline,
WA_EAM_S_TL_PLMZ_UPX-RGEKZ, sy-vline,
WA_EAM_S_TL_PLMZ_UPX-DISP, sy-vline,
WA_EAM_S_TL_PLMZ_UPX-MENGE, sy-vline,
WA_EAM_S_TL_PLMZ_UPX-MEINS, sy-vline,
WA_EAM_S_TL_PLMZ_UPX-ABLAD, sy-vline.
ENDLOOP. *Add any further fields from structure WA_EAM_S_TL_PLMZ_UPX you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_EAM_S_TL_PLMZ_UPX TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_EAM_S_TL_PLMZ_UPX INTO WA_EAM_S_TL_PLMZ_UPX. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ALPHA, internal->external for field PLNNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EAM_S_TL_PLMZ_UPX-PLNNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAM_S_TL_PLMZ_UPX-PLNNR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field PLNAL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EAM_S_TL_PLMZ_UPX-PLNAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAM_S_TL_PLMZ_UPX-PLNAL.
WRITE:/ 'New Value:', ld_input.
*Conversion exit NUMCV, internal->external for field VORNR CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_EAM_S_TL_PLMZ_UPX-VORNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAM_S_TL_PLMZ_UPX-VORNR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_EAM_S_TL_PLMZ_UPX_STR,
PLNTY TYPE STRING,
PLNNR TYPE STRING,
PLNAL TYPE STRING,
PLNKN TYPE STRING,
ZUONR TYPE STRING,
VORNR TYPE STRING,
RGEKZ TYPE STRING,
DISP TYPE STRING,
MENGE TYPE STRING,
MEINS TYPE STRING,
ABLAD TYPE STRING,
WEMPF TYPE STRING,END OF T_EKKO_STR. DATA: WA_EAM_S_TL_PLMZ_UPX_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_EAM_S_TL_PLMZ_UPX_STR-PLNTY sy-vline
WA_EAM_S_TL_PLMZ_UPX_STR-PLNNR sy-vline
WA_EAM_S_TL_PLMZ_UPX_STR-PLNAL sy-vline
WA_EAM_S_TL_PLMZ_UPX_STR-PLNKN sy-vline
WA_EAM_S_TL_PLMZ_UPX_STR-ZUONR sy-vline
WA_EAM_S_TL_PLMZ_UPX_STR-VORNR sy-vline
WA_EAM_S_TL_PLMZ_UPX_STR-RGEKZ sy-vline
WA_EAM_S_TL_PLMZ_UPX_STR-DISP sy-vline
WA_EAM_S_TL_PLMZ_UPX_STR-MENGE sy-vline
WA_EAM_S_TL_PLMZ_UPX_STR-MEINS sy-vline
WA_EAM_S_TL_PLMZ_UPX_STR-ABLAD sy-vline
WA_EAM_S_TL_PLMZ_UPX_STR-WEMPF sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.