ABAP Select data from SAP table EAMS_S_BO_ORD_OPER_WKC into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP EAMS_S_BO_ORD_OPER_WKC table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to EAMS_S_BO_ORD_OPER_WKC. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the EAMS_S_BO_ORD_OPER_WKC table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_EAMS_S_BO_ORD_OPER_WKC TYPE STANDARD TABLE OF EAMS_S_BO_ORD_OPER_WKC,
      WA_EAMS_S_BO_ORD_OPER_WKC TYPE EAMS_S_BO_ORD_OPER_WKC,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <EAMS_S_BO_ORD_OPER_WKC> TYPE EAMS_S_BO_ORD_OPER_WKC.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_EAMS_S_BO_ORD_OPER_WKC.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM EAMS_S_BO_ORD_OPER_WKC
  INTO TABLE IT_EAMS_S_BO_ORD_OPER_WKC.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM EAMS_S_BO_ORD_OPER_WKC
*  INTO TABLE @DATA(IT_EAMS_S_BO_ORD_OPER_WKC2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_EAMS_S_BO_ORD_OPER_WKC INDEX 1 INTO DATA(WA_EAMS_S_BO_ORD_OPER_WKC2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_EAMS_S_BO_ORD_OPER_WKC ASSIGNING <EAMS_S_BO_ORD_OPER_WKC>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<EAMS_S_BO_ORD_OPER_WKC>-EAMS_AUFNR = 1.
<EAMS_S_BO_ORD_OPER_WKC>-EAMS_VORNR = 1.
<EAMS_S_BO_ORD_OPER_WKC>-EAMS_UVORN = 1.
<EAMS_S_BO_ORD_OPER_WKC>-MANDT = 1.
<EAMS_S_BO_ORD_OPER_WKC>-OBJTY = 1.
ENDLOOP.

LOOP AT IT_EAMS_S_BO_ORD_OPER_WKC INTO WA_EAMS_S_BO_ORD_OPER_WKC.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_EAMS_S_BO_ORD_OPER_WKC-OBJID, sy-vline,
WA_EAMS_S_BO_ORD_OPER_WKC-BEGDA, sy-vline,
WA_EAMS_S_BO_ORD_OPER_WKC-ENDDA, sy-vline,
WA_EAMS_S_BO_ORD_OPER_WKC-AEDAT_GRND, sy-vline,
WA_EAMS_S_BO_ORD_OPER_WKC-AENAM_GRND, sy-vline,
WA_EAMS_S_BO_ORD_OPER_WKC-AEDAT_VORA, sy-vline.
ENDLOOP. *Add any further fields from structure WA_EAMS_S_BO_ORD_OPER_WKC you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_EAMS_S_BO_ORD_OPER_WKC TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_EAMS_S_BO_ORD_OPER_WKC INTO WA_EAMS_S_BO_ORD_OPER_WKC. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field EAMS_AUFNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EAMS_S_BO_ORD_OPER_WKC-EAMS_AUFNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_BO_ORD_OPER_WKC-EAMS_AUFNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit NUMCV, internal->external for field EAMS_VORNR CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_EAMS_S_BO_ORD_OPER_WKC-EAMS_VORNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_BO_ORD_OPER_WKC-EAMS_VORNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit NUMCV, internal->external for field EAMS_UVORN CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_EAMS_S_BO_ORD_OPER_WKC-EAMS_UVORN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_BO_ORD_OPER_WKC-EAMS_UVORN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field PARU1 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_EAMS_S_BO_ORD_OPER_WKC-PARU1 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_BO_ORD_OPER_WKC-PARU1.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field PARU2 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_EAMS_S_BO_ORD_OPER_WKC-PARU2 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_BO_ORD_OPER_WKC-PARU2.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field PARU3 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_EAMS_S_BO_ORD_OPER_WKC-PARU3 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_BO_ORD_OPER_WKC-PARU3.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field PARU4 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_EAMS_S_BO_ORD_OPER_WKC-PARU4 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_BO_ORD_OPER_WKC-PARU4.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field PARU5 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_EAMS_S_BO_ORD_OPER_WKC-PARU5 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_BO_ORD_OPER_WKC-PARU5.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field PARU6 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_EAMS_S_BO_ORD_OPER_WKC-PARU6 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_BO_ORD_OPER_WKC-PARU6.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field VGE01 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_EAMS_S_BO_ORD_OPER_WKC-VGE01 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_BO_ORD_OPER_WKC-VGE01.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field VGE02 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_EAMS_S_BO_ORD_OPER_WKC-VGE02 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_BO_ORD_OPER_WKC-VGE02.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field VGE03 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_EAMS_S_BO_ORD_OPER_WKC-VGE03 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_BO_ORD_OPER_WKC-VGE03.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field VGE04 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_EAMS_S_BO_ORD_OPER_WKC-VGE04 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_BO_ORD_OPER_WKC-VGE04.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field VGE05 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_EAMS_S_BO_ORD_OPER_WKC-VGE05 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_BO_ORD_OPER_WKC-VGE05.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field VGE06 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_EAMS_S_BO_ORD_OPER_WKC-VGE06 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_BO_ORD_OPER_WKC-VGE06.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field ZEIWN CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_EAMS_S_BO_ORD_OPER_WKC-ZEIWN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_BO_ORD_OPER_WKC-ZEIWN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field ZEIWM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_EAMS_S_BO_ORD_OPER_WKC-ZEIWM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_BO_ORD_OPER_WKC-ZEIWM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit SPDEV, internal->external for field PDEST CALL FUNCTION 'CONVERSION_EXIT_SPDEV_OUTPUT' EXPORTING input = WA_EAMS_S_BO_ORD_OPER_WKC-PDEST IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_BO_ORD_OPER_WKC-PDEST.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field LIFNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EAMS_S_BO_ORD_OPER_WKC-LIFNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_BO_ORD_OPER_WKC-LIFNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field VGARB CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_EAMS_S_BO_ORD_OPER_WKC-VGARB IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_BO_ORD_OPER_WKC-VGARB.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field VGDAU CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_EAMS_S_BO_ORD_OPER_WKC-VGDAU IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_BO_ORD_OPER_WKC-VGDAU.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_EAMS_S_BO_ORD_OPER_WKC_STR,
EAMS_AUFNR TYPE STRING,
EAMS_VORNR TYPE STRING,
EAMS_UVORN TYPE STRING,
MANDT TYPE STRING,
OBJTY TYPE STRING,
OBJID TYPE STRING,
BEGDA TYPE STRING,
ENDDA TYPE STRING,
AEDAT_GRND TYPE STRING,
AENAM_GRND TYPE STRING,
AEDAT_VORA TYPE STRING,
AENAM_VORA TYPE STRING,
AEDAT_TERM TYPE STRING,
AENAM_TERM TYPE STRING,
AEDAT_TECH TYPE STRING,
AENAM_TECH TYPE STRING,
ARBPL TYPE STRING,
WERKS TYPE STRING,
VERWE TYPE STRING,
LVORM TYPE STRING,
PAR01 TYPE STRING,
PAR02 TYPE STRING,
PAR03 TYPE STRING,
PAR04 TYPE STRING,
PAR05 TYPE STRING,
PAR06 TYPE STRING,
PARU1 TYPE STRING,
PARU2 TYPE STRING,
PARU3 TYPE STRING,
PARU4 TYPE STRING,
PARU5 TYPE STRING,
PARU6 TYPE STRING,
PARV1 TYPE STRING,
PARV2 TYPE STRING,
PARV3 TYPE STRING,
PARV4 TYPE STRING,
PARV5 TYPE STRING,
PARV6 TYPE STRING,
PLANV TYPE STRING,
STAND TYPE STRING,
VERAN TYPE STRING,
VGWTS TYPE STRING,
VGM01 TYPE STRING,
VGM02 TYPE STRING,
VGM03 TYPE STRING,
VGM04 TYPE STRING,
VGM05 TYPE STRING,
VGM06 TYPE STRING,
XDEFA TYPE STRING,
XKOST TYPE STRING,
XSPRR TYPE STRING,
XTERM TYPE STRING,
ZGR01 TYPE STRING,
ZGR02 TYPE STRING,
ZGR03 TYPE STRING,
ZGR04 TYPE STRING,
ZGR05 TYPE STRING,
ZGR06 TYPE STRING,
KTSCH TYPE STRING,
LOANZ TYPE STRING,
LOART TYPE STRING,
LOGRP TYPE STRING,
QUALF TYPE STRING,
RASCH TYPE STRING,
STEUS TYPE STRING,
VGE01 TYPE STRING,
VGE02 TYPE STRING,
VGE03 TYPE STRING,
VGE04 TYPE STRING,
VGE05 TYPE STRING,
VGE06 TYPE STRING,
KTSCH_REF TYPE STRING,
LOART_REF TYPE STRING,
LOANZ_REF TYPE STRING,
LOGRP_REF TYPE STRING,
QUALF_REF TYPE STRING,
RASCH_REF TYPE STRING,
STEUS_REF TYPE STRING,
FORT1 TYPE STRING,
FORT2 TYPE STRING,
FORT3 TYPE STRING,
KAPID TYPE STRING,
ORTGR TYPE STRING,
ZEIWN TYPE STRING,
ZWNOR TYPE STRING,
ZEIWM TYPE STRING,
ZWMIN TYPE STRING,
FORMR TYPE STRING,
MATYP TYPE STRING,
CPLGR TYPE STRING,
SORTB TYPE STRING,
MTRVP TYPE STRING,
MTMVP TYPE STRING,
MTPVP TYPE STRING,
RSANZ TYPE STRING,
PDEST TYPE STRING,
HROID TYPE STRING,
FORTN TYPE STRING,
ZGR01_REF TYPE STRING,
ZGR02_REF TYPE STRING,
ZGR03_REF TYPE STRING,
ZGR04_REF TYPE STRING,
ZGR05_REF TYPE STRING,
ZGR06_REF TYPE STRING,
STEUS_C TYPE STRING,
STEUS_I TYPE STRING,
STEUS_N TYPE STRING,
STEUS_Q TYPE STRING,
RUZUS TYPE STRING,
RSANZ_REF TYPE STRING,
HR TYPE STRING,
PRVBE TYPE STRING,
SUBSYS TYPE STRING,
BDEGR TYPE STRING,
RGEKZ TYPE STRING,
HRTYP TYPE STRING,
SLWID TYPE STRING,
LIFNR TYPE STRING,
SLWID_REF TYPE STRING,
LIFNR_REF TYPE STRING,
VGARB TYPE STRING,
VGDIM TYPE STRING,
HRPLVAR TYPE STRING,
VGDAU TYPE STRING,
STOBJ TYPE STRING,
RESGR TYPE STRING,
LGORT_RES TYPE STRING,
MIXMAT TYPE STRING,
ISTBED_KZ TYPE STRING,
LASTCHANGE_DATETIME TYPE STRING,
PPSKZ TYPE STRING,
SRTYPE TYPE STRING,
SNTYPE TYPE STRING,
S_LABOR_TRACK TYPE STRING,
SELECTED TYPE STRING,
ARBPL_TEXT TYPE STRING,END OF T_EKKO_STR. DATA: WA_EAMS_S_BO_ORD_OPER_WKC_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-EAMS_AUFNR sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-EAMS_VORNR sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-EAMS_UVORN sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-MANDT sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-OBJTY sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-OBJID sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-BEGDA sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-ENDDA sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-AEDAT_GRND sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-AENAM_GRND sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-AEDAT_VORA sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-AENAM_VORA sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-AEDAT_TERM sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-AENAM_TERM sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-AEDAT_TECH sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-AENAM_TECH sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-ARBPL sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-WERKS sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-VERWE sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-LVORM sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-PAR01 sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-PAR02 sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-PAR03 sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-PAR04 sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-PAR05 sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-PAR06 sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-PARU1 sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-PARU2 sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-PARU3 sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-PARU4 sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-PARU5 sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-PARU6 sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-PARV1 sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-PARV2 sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-PARV3 sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-PARV4 sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-PARV5 sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-PARV6 sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-PLANV sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-STAND sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-VERAN sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-VGWTS sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-VGM01 sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-VGM02 sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-VGM03 sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-VGM04 sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-VGM05 sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-VGM06 sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-XDEFA sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-XKOST sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-XSPRR sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-XTERM sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-ZGR01 sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-ZGR02 sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-ZGR03 sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-ZGR04 sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-ZGR05 sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-ZGR06 sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-KTSCH sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-LOANZ sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-LOART sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-LOGRP sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-QUALF sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-RASCH sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-STEUS sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-VGE01 sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-VGE02 sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-VGE03 sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-VGE04 sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-VGE05 sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-VGE06 sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-KTSCH_REF sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-LOART_REF sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-LOANZ_REF sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-LOGRP_REF sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-QUALF_REF sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-RASCH_REF sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-STEUS_REF sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-FORT1 sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-FORT2 sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-FORT3 sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-KAPID sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-ORTGR sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-ZEIWN sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-ZWNOR sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-ZEIWM sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-ZWMIN sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-FORMR sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-MATYP sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-CPLGR sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-SORTB sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-MTRVP sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-MTMVP sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-MTPVP sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-RSANZ sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-PDEST sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-HROID sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-FORTN sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-ZGR01_REF sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-ZGR02_REF sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-ZGR03_REF sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-ZGR04_REF sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-ZGR05_REF sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-ZGR06_REF sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-STEUS_C sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-STEUS_I sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-STEUS_N sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-STEUS_Q sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-RUZUS sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-RSANZ_REF sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-HR sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-PRVBE sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-SUBSYS sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-BDEGR sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-RGEKZ sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-HRTYP sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-SLWID sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-LIFNR sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-SLWID_REF sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-LIFNR_REF sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-VGARB sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-VGDIM sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-HRPLVAR sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-VGDAU sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-STOBJ sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-RESGR sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-LGORT_RES sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-MIXMAT sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-ISTBED_KZ sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-LASTCHANGE_DATETIME sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-PPSKZ sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-SRTYPE sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-SNTYPE sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-S_LABOR_TRACK sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-SELECTED sy-vline
WA_EAMS_S_BO_ORD_OPER_WKC_STR-ARBPL_TEXT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.