ABAP Select data from SAP table EAMS_S_BO_RFL into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP EAMS_S_BO_RFL table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to EAMS_S_BO_RFL. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the EAMS_S_BO_RFL table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_EAMS_S_BO_RFL TYPE STANDARD TABLE OF EAMS_S_BO_RFL,
      WA_EAMS_S_BO_RFL TYPE EAMS_S_BO_RFL,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <EAMS_S_BO_RFL> TYPE EAMS_S_BO_RFL.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_EAMS_S_BO_RFL.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM EAMS_S_BO_RFL
  INTO TABLE IT_EAMS_S_BO_RFL.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM EAMS_S_BO_RFL
*  INTO TABLE @DATA(IT_EAMS_S_BO_RFL2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_EAMS_S_BO_RFL INDEX 1 INTO DATA(WA_EAMS_S_BO_RFL2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_EAMS_S_BO_RFL ASSIGNING <EAMS_S_BO_RFL>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<EAMS_S_BO_RFL>-EAMS_TRPNR = 1.
<EAMS_S_BO_RFL>-MANDT = 1.
<EAMS_S_BO_RFL>-TRPNR = 1.
<EAMS_S_BO_RFL>-SPRAS = 1.
<EAMS_S_BO_RFL>-PLTXT = 1.
ENDLOOP.

LOOP AT IT_EAMS_S_BO_RFL INTO WA_EAMS_S_BO_RFL.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_EAMS_S_BO_RFL-KZLTX, sy-vline,
WA_EAMS_S_BO_RFL-KZMLA, sy-vline,
WA_EAMS_S_BO_RFL-PLTXU, sy-vline,
WA_EAMS_S_BO_RFL-MLANG, sy-vline,
WA_EAMS_S_BO_RFL-TPLKZ, sy-vline,
WA_EAMS_S_BO_RFL-RLTYP, sy-vline.
ENDLOOP. *Add any further fields from structure WA_EAMS_S_BO_RFL you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_EAMS_S_BO_RFL TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_EAMS_S_BO_RFL INTO WA_EAMS_S_BO_RFL. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ISOLA, internal->external for field SPRAS CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_EAMS_S_BO_RFL-SPRAS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_BO_RFL-SPRAS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ISOLA, internal->external for field MLANG CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_EAMS_S_BO_RFL-MLANG IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_BO_RFL-MLANG.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field SUBMT CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_EAMS_S_BO_RFL-SUBMT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_BO_RFL-SUBMT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_EAMS_S_BO_RFL_STR,
EAMS_TRPNR TYPE STRING,
MANDT TYPE STRING,
TRPNR TYPE STRING,
SPRAS TYPE STRING,
PLTXT TYPE STRING,
KZLTX TYPE STRING,
KZMLA TYPE STRING,
PLTXU TYPE STRING,
MLANG TYPE STRING,
TPLKZ TYPE STRING,
RLTYP TYPE STRING,
TRPMA TYPE STRING,
ERDAT TYPE STRING,
ERNAM TYPE STRING,
AEDAT TYPE STRING,
AENAM TYPE STRING,
BEGRU TYPE STRING,
LVORM TYPE STRING,
SUBMT TYPE STRING,
MAPAR TYPE STRING,
IEQUI TYPE STRING,
IEQUII TYPE STRING,
EINZL TYPE STRING,
EINZLI TYPE STRING,
IWERK TYPE STRING,
IWERKI TYPE STRING,
INGRP TYPE STRING,
INGRPI TYPE STRING,
PM_OBJTY TYPE STRING,
LGWID TYPE STRING,
LGWIDI TYPE STRING,
RBNR TYPE STRING,
RBNR_I TYPE STRING,
ABCKZ TYPE STRING,
ABCKZI TYPE STRING,
OBJNR TYPE STRING,END OF T_EKKO_STR. DATA: WA_EAMS_S_BO_RFL_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_EAMS_S_BO_RFL_STR-EAMS_TRPNR sy-vline
WA_EAMS_S_BO_RFL_STR-MANDT sy-vline
WA_EAMS_S_BO_RFL_STR-TRPNR sy-vline
WA_EAMS_S_BO_RFL_STR-SPRAS sy-vline
WA_EAMS_S_BO_RFL_STR-PLTXT sy-vline
WA_EAMS_S_BO_RFL_STR-KZLTX sy-vline
WA_EAMS_S_BO_RFL_STR-KZMLA sy-vline
WA_EAMS_S_BO_RFL_STR-PLTXU sy-vline
WA_EAMS_S_BO_RFL_STR-MLANG sy-vline
WA_EAMS_S_BO_RFL_STR-TPLKZ sy-vline
WA_EAMS_S_BO_RFL_STR-RLTYP sy-vline
WA_EAMS_S_BO_RFL_STR-TRPMA sy-vline
WA_EAMS_S_BO_RFL_STR-ERDAT sy-vline
WA_EAMS_S_BO_RFL_STR-ERNAM sy-vline
WA_EAMS_S_BO_RFL_STR-AEDAT sy-vline
WA_EAMS_S_BO_RFL_STR-AENAM sy-vline
WA_EAMS_S_BO_RFL_STR-BEGRU sy-vline
WA_EAMS_S_BO_RFL_STR-LVORM sy-vline
WA_EAMS_S_BO_RFL_STR-SUBMT sy-vline
WA_EAMS_S_BO_RFL_STR-MAPAR sy-vline
WA_EAMS_S_BO_RFL_STR-IEQUI sy-vline
WA_EAMS_S_BO_RFL_STR-IEQUII sy-vline
WA_EAMS_S_BO_RFL_STR-EINZL sy-vline
WA_EAMS_S_BO_RFL_STR-EINZLI sy-vline
WA_EAMS_S_BO_RFL_STR-IWERK sy-vline
WA_EAMS_S_BO_RFL_STR-IWERKI sy-vline
WA_EAMS_S_BO_RFL_STR-INGRP sy-vline
WA_EAMS_S_BO_RFL_STR-INGRPI sy-vline
WA_EAMS_S_BO_RFL_STR-PM_OBJTY sy-vline
WA_EAMS_S_BO_RFL_STR-LGWID sy-vline
WA_EAMS_S_BO_RFL_STR-LGWIDI sy-vline
WA_EAMS_S_BO_RFL_STR-RBNR sy-vline
WA_EAMS_S_BO_RFL_STR-RBNR_I sy-vline
WA_EAMS_S_BO_RFL_STR-ABCKZ sy-vline
WA_EAMS_S_BO_RFL_STR-ABCKZI sy-vline
WA_EAMS_S_BO_RFL_STR-OBJNR sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.