ABAP Select data from SAP table EAMS_S_BO_TL_OP_PRT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP EAMS_S_BO_TL_OP_PRT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to EAMS_S_BO_TL_OP_PRT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the EAMS_S_BO_TL_OP_PRT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_EAMS_S_BO_TL_OP_PRT TYPE STANDARD TABLE OF EAMS_S_BO_TL_OP_PRT,
      WA_EAMS_S_BO_TL_OP_PRT TYPE EAMS_S_BO_TL_OP_PRT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <EAMS_S_BO_TL_OP_PRT> TYPE EAMS_S_BO_TL_OP_PRT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_EAMS_S_BO_TL_OP_PRT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM EAMS_S_BO_TL_OP_PRT
  INTO TABLE IT_EAMS_S_BO_TL_OP_PRT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM EAMS_S_BO_TL_OP_PRT
*  INTO TABLE @DATA(IT_EAMS_S_BO_TL_OP_PRT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_EAMS_S_BO_TL_OP_PRT INDEX 1 INTO DATA(WA_EAMS_S_BO_TL_OP_PRT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_EAMS_S_BO_TL_OP_PRT ASSIGNING <EAMS_S_BO_TL_OP_PRT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<EAMS_S_BO_TL_OP_PRT>-EAMS_PLNTY = 1.
<EAMS_S_BO_TL_OP_PRT>-EAMS_PLNNR = 1.
<EAMS_S_BO_TL_OP_PRT>-EAMS_PLNAL = 1.
<EAMS_S_BO_TL_OP_PRT>-EAMS_PLNKN = 1.
<EAMS_S_BO_TL_OP_PRT>-EAMS_VORNR = 1.
ENDLOOP.

LOOP AT IT_EAMS_S_BO_TL_OP_PRT INTO WA_EAMS_S_BO_TL_OP_PRT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_EAMS_S_BO_TL_OP_PRT-EAMS_PZLFH, sy-vline,
WA_EAMS_S_BO_TL_OP_PRT-PLNTY, sy-vline,
WA_EAMS_S_BO_TL_OP_PRT-PLNNR, sy-vline,
WA_EAMS_S_BO_TL_OP_PRT-PLNAL, sy-vline,
WA_EAMS_S_BO_TL_OP_PRT-PZLFH, sy-vline,
WA_EAMS_S_BO_TL_OP_PRT-PLNKN, sy-vline.
ENDLOOP. *Add any further fields from structure WA_EAMS_S_BO_TL_OP_PRT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_EAMS_S_BO_TL_OP_PRT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_EAMS_S_BO_TL_OP_PRT INTO WA_EAMS_S_BO_TL_OP_PRT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field EAMS_PLNNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EAMS_S_BO_TL_OP_PRT-EAMS_PLNNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_BO_TL_OP_PRT-EAMS_PLNNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field EAMS_PLNAL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EAMS_S_BO_TL_OP_PRT-EAMS_PLNAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_BO_TL_OP_PRT-EAMS_PLNAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit NUMCV, internal->external for field EAMS_VORNR CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_EAMS_S_BO_TL_OP_PRT-EAMS_VORNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_BO_TL_OP_PRT-EAMS_VORNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PLNNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EAMS_S_BO_TL_OP_PRT-PLNNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_BO_TL_OP_PRT-PLNNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PLNAL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EAMS_S_BO_TL_OP_PRT-PLNAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_BO_TL_OP_PRT-PLNAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit NUMCV, internal->external for field VORNR CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_EAMS_S_BO_TL_OP_PRT-VORNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_BO_TL_OP_PRT-VORNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field EHOFFB CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_EAMS_S_BO_TL_OP_PRT-EHOFFB IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_BO_TL_OP_PRT-EHOFFB.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field EHOFFE CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_EAMS_S_BO_TL_OP_PRT-EHOFFE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_BO_TL_OP_PRT-EHOFFE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MGEINH CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_EAMS_S_BO_TL_OP_PRT-MGEINH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_BO_TL_OP_PRT-MGEINH.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field EWEINH CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_EAMS_S_BO_TL_OP_PRT-EWEINH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_BO_TL_OP_PRT-EWEINH.
WRITE:/ 'New Value:', ld_input.

*Conversion exit FHMAR, internal->external for field FHMAR CALL FUNCTION 'CONVERSION_EXIT_FHMAR_OUTPUT' EXPORTING input = WA_EAMS_S_BO_TL_OP_PRT-FHMAR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_BO_TL_OP_PRT-FHMAR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_EAMS_S_BO_TL_OP_PRT-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_BO_TL_OP_PRT-MATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SFHNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EAMS_S_BO_TL_OP_PRT-SFHNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_BO_TL_OP_PRT-SFHNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field DOKNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EAMS_S_BO_TL_OP_PRT-DOKNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_BO_TL_OP_PRT-DOKNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field EQUNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EAMS_S_BO_TL_OP_PRT-EQUNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_BO_TL_OP_PRT-EQUNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field EQPNT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EAMS_S_BO_TL_OP_PRT-EQPNT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_BO_TL_OP_PRT-EQPNT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field AENNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EAMS_S_BO_TL_OP_PRT-AENNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_BO_TL_OP_PRT-AENNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ISOLA, internal->external for field TXTSP CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_EAMS_S_BO_TL_OP_PRT-TXTSP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_BO_TL_OP_PRT-TXTSP.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field EQWPL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EAMS_S_BO_TL_OP_PRT-EQWPL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_BO_TL_OP_PRT-EQWPL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MSEHI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_EAMS_S_BO_TL_OP_PRT-MSEHI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_BO_TL_OP_PRT-MSEHI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field BASEH CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_EAMS_S_BO_TL_OP_PRT-BASEH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_BO_TL_OP_PRT-BASEH.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MEINS CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_EAMS_S_BO_TL_OP_PRT-MEINS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_BO_TL_OP_PRT-MEINS.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_EAMS_S_BO_TL_OP_PRT_STR,
EAMS_PLNTY TYPE STRING,
EAMS_PLNNR TYPE STRING,
EAMS_PLNAL TYPE STRING,
EAMS_PLNKN TYPE STRING,
EAMS_VORNR TYPE STRING,
EAMS_PZLFH TYPE STRING,
PLNTY TYPE STRING,
PLNNR TYPE STRING,
PLNAL TYPE STRING,
PZLFH TYPE STRING,
PLNKN TYPE STRING,
VORNR TYPE STRING,
PSNFH TYPE STRING,
STEUF TYPE STRING,
OFFSTB TYPE STRING,
EHOFFB TYPE STRING,
CF_KZSVS TYPE STRING,
CF_KZSVE TYPE STRING,
OFFSTE TYPE STRING,
EHOFFE TYPE STRING,
CF_KZEVS TYPE STRING,
CF_KZEVE TYPE STRING,
MGEINH TYPE STRING,
MGVGW TYPE STRING,
MGFORM TYPE STRING,
EWEINH TYPE STRING,
EWVGW TYPE STRING,
EWFORM TYPE STRING,
KTSCH TYPE STRING,
TXTZ1 TYPE STRING,
FHMAR TYPE STRING,
FHWRK TYPE STRING,
MATNR TYPE STRING,
SFHNR TYPE STRING,
DOKAR TYPE STRING,
DOKNR TYPE STRING,
DOKTL TYPE STRING,
DOKVR TYPE STRING,
EQUNR TYPE STRING,
EQPNT TYPE STRING,
ZAEHL TYPE STRING,
DATUV TYPE STRING,
AENNR TYPE STRING,
DATUI TYPE STRING,
USERI TYPE STRING,
DATUC TYPE STRING,
USERC TYPE STRING,
OBJTY TYPE STRING,
OBJID TYPE STRING,
TXTSP TYPE STRING,
EQWPL TYPE STRING,
EQWTX TYPE STRING,
EQPTX TYPE STRING,
MSEHI TYPE STRING,
ATDIM TYPE STRING,
ANZDZ TYPE STRING,
FHKTX TYPE STRING,
BASEH TYPE STRING,
MEINS TYPE STRING,
FGRU1 TYPE STRING,
FGRU2 TYPE STRING,
STOWK TYPE STRING,
STORT TYPE STRING,
STEUF_REF TYPE STRING,
KTSCH_REF TYPE STRING,
BZOFFB_REF TYPE STRING,
OFFSTB_REF TYPE STRING,
BZOFFE_REF TYPE STRING,
OFFSTE_REF TYPE STRING,
MGFORM_REF TYPE STRING,
EWFORM_REF TYPE STRING,
DATUB TYPE STRING,
TXTKZ TYPE STRING,
FHMNR TYPE STRING,
FHWRK_TXT TYPE STRING,
DARTXT TYPE STRING,
STFTXT TYPE STRING,
MGFRM_TXT TYPE STRING,
EWFRM_TXT TYPE STRING,
MGEINH_TXT TYPE STRING,
EWEINH_TXT TYPE STRING,
EHOFFB_TXT TYPE STRING,
FAKTX TYPE STRING,
EHOFFE_TXT TYPE STRING,
SAFETY_CHAR TYPE STRING,
PRT_IND TYPE STRING,END OF T_EKKO_STR. DATA: WA_EAMS_S_BO_TL_OP_PRT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_EAMS_S_BO_TL_OP_PRT_STR-EAMS_PLNTY sy-vline
WA_EAMS_S_BO_TL_OP_PRT_STR-EAMS_PLNNR sy-vline
WA_EAMS_S_BO_TL_OP_PRT_STR-EAMS_PLNAL sy-vline
WA_EAMS_S_BO_TL_OP_PRT_STR-EAMS_PLNKN sy-vline
WA_EAMS_S_BO_TL_OP_PRT_STR-EAMS_VORNR sy-vline
WA_EAMS_S_BO_TL_OP_PRT_STR-EAMS_PZLFH sy-vline
WA_EAMS_S_BO_TL_OP_PRT_STR-PLNTY sy-vline
WA_EAMS_S_BO_TL_OP_PRT_STR-PLNNR sy-vline
WA_EAMS_S_BO_TL_OP_PRT_STR-PLNAL sy-vline
WA_EAMS_S_BO_TL_OP_PRT_STR-PZLFH sy-vline
WA_EAMS_S_BO_TL_OP_PRT_STR-PLNKN sy-vline
WA_EAMS_S_BO_TL_OP_PRT_STR-VORNR sy-vline
WA_EAMS_S_BO_TL_OP_PRT_STR-PSNFH sy-vline
WA_EAMS_S_BO_TL_OP_PRT_STR-STEUF sy-vline
WA_EAMS_S_BO_TL_OP_PRT_STR-OFFSTB sy-vline
WA_EAMS_S_BO_TL_OP_PRT_STR-EHOFFB sy-vline
WA_EAMS_S_BO_TL_OP_PRT_STR-CF_KZSVS sy-vline
WA_EAMS_S_BO_TL_OP_PRT_STR-CF_KZSVE sy-vline
WA_EAMS_S_BO_TL_OP_PRT_STR-OFFSTE sy-vline
WA_EAMS_S_BO_TL_OP_PRT_STR-EHOFFE sy-vline
WA_EAMS_S_BO_TL_OP_PRT_STR-CF_KZEVS sy-vline
WA_EAMS_S_BO_TL_OP_PRT_STR-CF_KZEVE sy-vline
WA_EAMS_S_BO_TL_OP_PRT_STR-MGEINH sy-vline
WA_EAMS_S_BO_TL_OP_PRT_STR-MGVGW sy-vline
WA_EAMS_S_BO_TL_OP_PRT_STR-MGFORM sy-vline
WA_EAMS_S_BO_TL_OP_PRT_STR-EWEINH sy-vline
WA_EAMS_S_BO_TL_OP_PRT_STR-EWVGW sy-vline
WA_EAMS_S_BO_TL_OP_PRT_STR-EWFORM sy-vline
WA_EAMS_S_BO_TL_OP_PRT_STR-KTSCH sy-vline
WA_EAMS_S_BO_TL_OP_PRT_STR-TXTZ1 sy-vline
WA_EAMS_S_BO_TL_OP_PRT_STR-FHMAR sy-vline
WA_EAMS_S_BO_TL_OP_PRT_STR-FHWRK sy-vline
WA_EAMS_S_BO_TL_OP_PRT_STR-MATNR sy-vline
WA_EAMS_S_BO_TL_OP_PRT_STR-SFHNR sy-vline
WA_EAMS_S_BO_TL_OP_PRT_STR-DOKAR sy-vline
WA_EAMS_S_BO_TL_OP_PRT_STR-DOKNR sy-vline
WA_EAMS_S_BO_TL_OP_PRT_STR-DOKTL sy-vline
WA_EAMS_S_BO_TL_OP_PRT_STR-DOKVR sy-vline
WA_EAMS_S_BO_TL_OP_PRT_STR-EQUNR sy-vline
WA_EAMS_S_BO_TL_OP_PRT_STR-EQPNT sy-vline
WA_EAMS_S_BO_TL_OP_PRT_STR-ZAEHL sy-vline
WA_EAMS_S_BO_TL_OP_PRT_STR-DATUV sy-vline
WA_EAMS_S_BO_TL_OP_PRT_STR-AENNR sy-vline
WA_EAMS_S_BO_TL_OP_PRT_STR-DATUI sy-vline
WA_EAMS_S_BO_TL_OP_PRT_STR-USERI sy-vline
WA_EAMS_S_BO_TL_OP_PRT_STR-DATUC sy-vline
WA_EAMS_S_BO_TL_OP_PRT_STR-USERC sy-vline
WA_EAMS_S_BO_TL_OP_PRT_STR-OBJTY sy-vline
WA_EAMS_S_BO_TL_OP_PRT_STR-OBJID sy-vline
WA_EAMS_S_BO_TL_OP_PRT_STR-TXTSP sy-vline
WA_EAMS_S_BO_TL_OP_PRT_STR-EQWPL sy-vline
WA_EAMS_S_BO_TL_OP_PRT_STR-EQWTX sy-vline
WA_EAMS_S_BO_TL_OP_PRT_STR-EQPTX sy-vline
WA_EAMS_S_BO_TL_OP_PRT_STR-MSEHI sy-vline
WA_EAMS_S_BO_TL_OP_PRT_STR-ATDIM sy-vline
WA_EAMS_S_BO_TL_OP_PRT_STR-ANZDZ sy-vline
WA_EAMS_S_BO_TL_OP_PRT_STR-FHKTX sy-vline
WA_EAMS_S_BO_TL_OP_PRT_STR-BASEH sy-vline
WA_EAMS_S_BO_TL_OP_PRT_STR-MEINS sy-vline
WA_EAMS_S_BO_TL_OP_PRT_STR-FGRU1 sy-vline
WA_EAMS_S_BO_TL_OP_PRT_STR-FGRU2 sy-vline
WA_EAMS_S_BO_TL_OP_PRT_STR-STOWK sy-vline
WA_EAMS_S_BO_TL_OP_PRT_STR-STORT sy-vline
WA_EAMS_S_BO_TL_OP_PRT_STR-STEUF_REF sy-vline
WA_EAMS_S_BO_TL_OP_PRT_STR-KTSCH_REF sy-vline
WA_EAMS_S_BO_TL_OP_PRT_STR-BZOFFB_REF sy-vline
WA_EAMS_S_BO_TL_OP_PRT_STR-OFFSTB_REF sy-vline
WA_EAMS_S_BO_TL_OP_PRT_STR-BZOFFE_REF sy-vline
WA_EAMS_S_BO_TL_OP_PRT_STR-OFFSTE_REF sy-vline
WA_EAMS_S_BO_TL_OP_PRT_STR-MGFORM_REF sy-vline
WA_EAMS_S_BO_TL_OP_PRT_STR-EWFORM_REF sy-vline
WA_EAMS_S_BO_TL_OP_PRT_STR-DATUB sy-vline
WA_EAMS_S_BO_TL_OP_PRT_STR-TXTKZ sy-vline
WA_EAMS_S_BO_TL_OP_PRT_STR-FHMNR sy-vline
WA_EAMS_S_BO_TL_OP_PRT_STR-FHWRK_TXT sy-vline
WA_EAMS_S_BO_TL_OP_PRT_STR-DARTXT sy-vline
WA_EAMS_S_BO_TL_OP_PRT_STR-STFTXT sy-vline
WA_EAMS_S_BO_TL_OP_PRT_STR-MGFRM_TXT sy-vline
WA_EAMS_S_BO_TL_OP_PRT_STR-EWFRM_TXT sy-vline
WA_EAMS_S_BO_TL_OP_PRT_STR-MGEINH_TXT sy-vline
WA_EAMS_S_BO_TL_OP_PRT_STR-EWEINH_TXT sy-vline
WA_EAMS_S_BO_TL_OP_PRT_STR-EHOFFB_TXT sy-vline
WA_EAMS_S_BO_TL_OP_PRT_STR-FAKTX sy-vline
WA_EAMS_S_BO_TL_OP_PRT_STR-EHOFFE_TXT sy-vline
WA_EAMS_S_BO_TL_OP_PRT_STR-SAFETY_CHAR sy-vline
WA_EAMS_S_BO_TL_OP_PRT_STR-PRT_IND sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.