ABAP Select data from SAP table EAMWS_S_SAFETYMEASURELIST into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP EAMWS_S_SAFETYMEASURELIST table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to EAMWS_S_SAFETYMEASURELIST. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the EAMWS_S_SAFETYMEASURELIST table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_EAMWS_S_SAFETYMEASURELIST TYPE STANDARD TABLE OF EAMWS_S_SAFETYMEASURELIST, WA_EAMWS_S_SAFETYMEASURELIST TYPE EAMWS_S_SAFETYMEASURELIST, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <EAMWS_S_SAFETYMEASURELIST> TYPE EAMWS_S_SAFETYMEASURELIST. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_EAMWS_S_SAFETYMEASURELIST. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM EAMWS_S_SAFETYMEASURELIST INTO TABLE IT_EAMWS_S_SAFETYMEASURELIST. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM EAMWS_S_SAFETYMEASURELIST * INTO TABLE @DATA(IT_EAMWS_S_SAFETYMEASURELIST2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_EAMWS_S_SAFETYMEASURELIST INDEX 1 INTO DATA(WA_EAMWS_S_SAFETYMEASURELIST2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_EAMWS_S_SAFETYMEASURELIST ASSIGNING <EAMWS_S_SAFETYMEASURELIST>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<EAMWS_S_SAFETYMEASURELIST>-EAMS_AUFNR = 1.
<EAMWS_S_SAFETYMEASURELIST>-EAMS_VORNR = 1.
<EAMWS_S_SAFETYMEASURELIST>-OBJ_TYPE = 1.
<EAMWS_S_SAFETYMEASURELIST>-OBJ_ID = 1.
<EAMWS_S_SAFETYMEASURELIST>-PARENT_KEY = 1.
ENDLOOP. LOOP AT IT_EAMWS_S_SAFETYMEASURELIST INTO WA_EAMWS_S_SAFETYMEASURELIST. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_EAMWS_S_SAFETYMEASURELIST-ROW_KEY, sy-vline,
WA_EAMWS_S_SAFETYMEASURELIST-IS_LEAF, sy-vline,
WA_EAMWS_S_SAFETYMEASURELIST-DESCRIPTION, sy-vline,
WA_EAMWS_S_SAFETYMEASURELIST-IMAGE_SRC, sy-vline,
WA_EAMWS_S_SAFETYMEASURELIST-SAFETY_CHAR, sy-vline,
WA_EAMWS_S_SAFETYMEASURELIST-PRT_IND, sy-vline.
ENDLOOP. *Add any further fields from structure WA_EAMWS_S_SAFETYMEASURELIST you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_EAMWS_S_SAFETYMEASURELIST TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_EAMWS_S_SAFETYMEASURELIST INTO WA_EAMWS_S_SAFETYMEASURELIST. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ALPHA, internal->external for field EAMS_AUFNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EAMWS_S_SAFETYMEASURELIST-EAMS_AUFNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMWS_S_SAFETYMEASURELIST-EAMS_AUFNR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit NUMCV, internal->external for field EAMS_VORNR CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_EAMWS_S_SAFETYMEASURELIST-EAMS_VORNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMWS_S_SAFETYMEASURELIST-EAMS_VORNR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_EAMWS_S_SAFETYMEASURELIST_STR,
EAMS_AUFNR TYPE STRING,
EAMS_VORNR TYPE STRING,
OBJ_TYPE TYPE STRING,
OBJ_ID TYPE STRING,
PARENT_KEY TYPE STRING,
ROW_KEY TYPE STRING,
IS_LEAF TYPE STRING,
DESCRIPTION TYPE STRING,
IMAGE_SRC TYPE STRING,
SAFETY_CHAR TYPE STRING,
PRT_IND TYPE STRING,
EXT_OBJ_ID TYPE STRING,
OBJ_TYPE_TXT TYPE STRING,
SAFETY_CHAR_TXT TYPE STRING,END OF T_EKKO_STR. DATA: WA_EAMWS_S_SAFETYMEASURELIST_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_EAMWS_S_SAFETYMEASURELIST_STR-EAMS_AUFNR sy-vline
WA_EAMWS_S_SAFETYMEASURELIST_STR-EAMS_VORNR sy-vline
WA_EAMWS_S_SAFETYMEASURELIST_STR-OBJ_TYPE sy-vline
WA_EAMWS_S_SAFETYMEASURELIST_STR-OBJ_ID sy-vline
WA_EAMWS_S_SAFETYMEASURELIST_STR-PARENT_KEY sy-vline
WA_EAMWS_S_SAFETYMEASURELIST_STR-ROW_KEY sy-vline
WA_EAMWS_S_SAFETYMEASURELIST_STR-IS_LEAF sy-vline
WA_EAMWS_S_SAFETYMEASURELIST_STR-DESCRIPTION sy-vline
WA_EAMWS_S_SAFETYMEASURELIST_STR-IMAGE_SRC sy-vline
WA_EAMWS_S_SAFETYMEASURELIST_STR-SAFETY_CHAR sy-vline
WA_EAMWS_S_SAFETYMEASURELIST_STR-PRT_IND sy-vline
WA_EAMWS_S_SAFETYMEASURELIST_STR-EXT_OBJ_ID sy-vline
WA_EAMWS_S_SAFETYMEASURELIST_STR-OBJ_TYPE_TXT sy-vline
WA_EAMWS_S_SAFETYMEASURELIST_STR-SAFETY_CHAR_TXT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.