ABAP Select data from SAP table ECATT_TEST_STRUC_30_DIGIT_NAME into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP ECATT_TEST_STRUC_30_DIGIT_NAME table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to ECATT_TEST_STRUC_30_DIGIT_NAME. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the ECATT_TEST_STRUC_30_DIGIT_NAME table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_ECATT_TEST_STRUC_30_DIGIT_NAME TYPE STANDARD TABLE OF ECATT_TEST_STRUC_30_DIGIT_NAME, WA_ECATT_TEST_STRUC_30_DIGIT_NAME TYPE ECATT_TEST_STRUC_30_DIGIT_NAME, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <ECATT_TEST_STRUC_30_DIGIT_NAME> TYPE ECATT_TEST_STRUC_30_DIGIT_NAME. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_ECATT_TEST_STRUC_30_DIGIT_NAME. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM ECATT_TEST_STRUC_30_DIGIT_NAME INTO TABLE IT_ECATT_TEST_STRUC_30_DIGIT_NAME. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM ECATT_TEST_STRUC_30_DIGIT_NAME * INTO TABLE @DATA(IT_ECATT_TEST_STRUC_30_DIGIT_NAME2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_ECATT_TEST_STRUC_30_DIGIT_NAME INDEX 1 INTO DATA(WA_ECATT_TEST_STRUC_30_DIGIT_NAME2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_ECATT_TEST_STRUC_30_DIGIT_NAME ASSIGNING <ECATT_TEST_STRUC_30_DIGIT_NAME>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<ECATT_TEST_STRUC_30_DIGIT_NAME>-CHARFIELD = 1.
<ECATT_TEST_STRUC_30_DIGIT_NAME>-DATEFIELD = 1.
<ECATT_TEST_STRUC_30_DIGIT_NAME>-TIMSFIELD = 1.
<ECATT_TEST_STRUC_30_DIGIT_NAME>-INTFIELD = 1.
<ECATT_TEST_STRUC_30_DIGIT_NAME>-NUMCFIELD = 1.
ENDLOOP. LOOP AT IT_ECATT_TEST_STRUC_30_DIGIT_NAME INTO WA_ECATT_TEST_STRUC_30_DIGIT_NAME. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_ECATT_TEST_STRUC_30_DIGIT_NAME-FLOATFIELD, sy-vline,
WA_ECATT_TEST_STRUC_30_DIGIT_NAME-STRINGFIELD, sy-vline,
WA_ECATT_TEST_STRUC_30_DIGIT_NAME-RAWFIELD, sy-vline,
WA_ECATT_TEST_STRUC_30_DIGIT_NAME-XSTRFIELD, sy-vline,
ENDLOOP. *Add any further fields from structure WA_ECATT_TEST_STRUC_30_DIGIT_NAME you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_ECATT_TEST_STRUC_30_DIGIT_NAME TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_ECATT_TEST_STRUC_30_DIGIT_NAME INTO WA_ECATT_TEST_STRUC_30_DIGIT_NAME. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_ECATT_TEST_STRUC_30_DIGIT_NAME_STR,
CHARFIELD TYPE STRING,
DATEFIELD TYPE STRING,
TIMSFIELD TYPE STRING,
INTFIELD TYPE STRING,
NUMCFIELD TYPE STRING,
FLOATFIELD TYPE STRING,
STRINGFIELD TYPE STRING,
RAWFIELD TYPE STRING,
XSTRFIELD TYPE STRING,END OF T_EKKO_STR. DATA: WA_ECATT_TEST_STRUC_30_DIGIT_NAME_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_ECATT_TEST_STRUC_30_DIGIT_NAME_STR-CHARFIELD sy-vline
WA_ECATT_TEST_STRUC_30_DIGIT_NAME_STR-DATEFIELD sy-vline
WA_ECATT_TEST_STRUC_30_DIGIT_NAME_STR-TIMSFIELD sy-vline
WA_ECATT_TEST_STRUC_30_DIGIT_NAME_STR-INTFIELD sy-vline
WA_ECATT_TEST_STRUC_30_DIGIT_NAME_STR-NUMCFIELD sy-vline
WA_ECATT_TEST_STRUC_30_DIGIT_NAME_STR-FLOATFIELD sy-vline
WA_ECATT_TEST_STRUC_30_DIGIT_NAME_STR-STRINGFIELD sy-vline
WA_ECATT_TEST_STRUC_30_DIGIT_NAME_STR-RAWFIELD sy-vline
WA_ECATT_TEST_STRUC_30_DIGIT_NAME_STR-XSTRFIELD sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.