ABAP Select data from SAP table ECN_CLASS_SEL into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP ECN_CLASS_SEL table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to ECN_CLASS_SEL. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the ECN_CLASS_SEL table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_ECN_CLASS_SEL TYPE STANDARD TABLE OF ECN_CLASS_SEL, WA_ECN_CLASS_SEL TYPE ECN_CLASS_SEL, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <ECN_CLASS_SEL> TYPE ECN_CLASS_SEL. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_ECN_CLASS_SEL. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM ECN_CLASS_SEL INTO TABLE IT_ECN_CLASS_SEL. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM ECN_CLASS_SEL * INTO TABLE @DATA(IT_ECN_CLASS_SEL2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_ECN_CLASS_SEL INDEX 1 INTO DATA(WA_ECN_CLASS_SEL2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_ECN_CLASS_SEL ASSIGNING <ECN_CLASS_SEL>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<ECN_CLASS_SEL>-AENNR = 1.
<ECN_CLASS_SEL>-AETXT = 1.
<ECN_CLASS_SEL>-MAT_FLG = 1.
<ECN_CLASS_SEL>-TSK_FLG = 1.
<ECN_CLASS_SEL>-SEQ_FLG = 1.
ENDLOOP. LOOP AT IT_ECN_CLASS_SEL INTO WA_ECN_CLASS_SEL. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_ECN_CLASS_SEL-OPR_FLG, sy-vline,
WA_ECN_CLASS_SEL-ODP_OPR_FLG, sy-vline,
WA_ECN_CLASS_SEL-CLA_OPR_FLG, sy-vline,
WA_ECN_CLASS_SEL-SUO_FLG, sy-vline,
WA_ECN_CLASS_SEL-ODP_SUO_FLG, sy-vline,
WA_ECN_CLASS_SEL-COM_FLG, sy-vline.
ENDLOOP. *Add any further fields from structure WA_ECN_CLASS_SEL you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_ECN_CLASS_SEL TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_ECN_CLASS_SEL INTO WA_ECN_CLASS_SEL. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ALPHA, internal->external for field AENNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ECN_CLASS_SEL-AENNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ECN_CLASS_SEL-AENNR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_ECN_CLASS_SEL_STR,
AENNR TYPE STRING,
AETXT TYPE STRING,
MAT_FLG TYPE STRING,
TSK_FLG TYPE STRING,
SEQ_FLG TYPE STRING,
OPR_FLG TYPE STRING,
ODP_OPR_FLG TYPE STRING,
CLA_OPR_FLG TYPE STRING,
SUO_FLG TYPE STRING,
ODP_SUO_FLG TYPE STRING,
COM_FLG TYPE STRING,
PRT_FLG TYPE STRING,
ODP_PRT_FLG TYPE STRING,
MST_FLG TYPE STRING,
CHA_FLG TYPE STRING,
BOM_FLG TYPE STRING,
ITM_FLG TYPE STRING,
ODP_ITM_FLG TYPE STRING,
CLA_ITM_FLG TYPE STRING,
SUI_FLG TYPE STRING,
ODP_FLG TYPE STRING,
PAC_FLG TYPE STRING,END OF T_EKKO_STR. DATA: WA_ECN_CLASS_SEL_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_ECN_CLASS_SEL_STR-AENNR sy-vline
WA_ECN_CLASS_SEL_STR-AETXT sy-vline
WA_ECN_CLASS_SEL_STR-MAT_FLG sy-vline
WA_ECN_CLASS_SEL_STR-TSK_FLG sy-vline
WA_ECN_CLASS_SEL_STR-SEQ_FLG sy-vline
WA_ECN_CLASS_SEL_STR-OPR_FLG sy-vline
WA_ECN_CLASS_SEL_STR-ODP_OPR_FLG sy-vline
WA_ECN_CLASS_SEL_STR-CLA_OPR_FLG sy-vline
WA_ECN_CLASS_SEL_STR-SUO_FLG sy-vline
WA_ECN_CLASS_SEL_STR-ODP_SUO_FLG sy-vline
WA_ECN_CLASS_SEL_STR-COM_FLG sy-vline
WA_ECN_CLASS_SEL_STR-PRT_FLG sy-vline
WA_ECN_CLASS_SEL_STR-ODP_PRT_FLG sy-vline
WA_ECN_CLASS_SEL_STR-MST_FLG sy-vline
WA_ECN_CLASS_SEL_STR-CHA_FLG sy-vline
WA_ECN_CLASS_SEL_STR-BOM_FLG sy-vline
WA_ECN_CLASS_SEL_STR-ITM_FLG sy-vline
WA_ECN_CLASS_SEL_STR-ODP_ITM_FLG sy-vline
WA_ECN_CLASS_SEL_STR-CLA_ITM_FLG sy-vline
WA_ECN_CLASS_SEL_STR-SUI_FLG sy-vline
WA_ECN_CLASS_SEL_STR-ODP_FLG sy-vline
WA_ECN_CLASS_SEL_STR-PAC_FLG sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.