ABAP Select data from SAP table EDO_CL_SIGN_WAYBILL_LEDGER_RE4 into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP EDO_CL_SIGN_WAYBILL_LEDGER_RE4 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to EDO_CL_SIGN_WAYBILL_LEDGER_RE4. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the EDO_CL_SIGN_WAYBILL_LEDGER_RE4 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_EDO_CL_SIGN_WAYBILL_LEDGER_RE4 TYPE STANDARD TABLE OF EDO_CL_SIGN_WAYBILL_LEDGER_RE4, WA_EDO_CL_SIGN_WAYBILL_LEDGER_RE4 TYPE EDO_CL_SIGN_WAYBILL_LEDGER_RE4, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <EDO_CL_SIGN_WAYBILL_LEDGER_RE4> TYPE EDO_CL_SIGN_WAYBILL_LEDGER_RE4. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_EDO_CL_SIGN_WAYBILL_LEDGER_RE4. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM EDO_CL_SIGN_WAYBILL_LEDGER_RE4 INTO TABLE IT_EDO_CL_SIGN_WAYBILL_LEDGER_RE4. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM EDO_CL_SIGN_WAYBILL_LEDGER_RE4 * INTO TABLE @DATA(IT_EDO_CL_SIGN_WAYBILL_LEDGER_RE42). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_EDO_CL_SIGN_WAYBILL_LEDGER_RE4 INDEX 1 INTO DATA(WA_EDO_CL_SIGN_WAYBILL_LEDGER_RE42). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_EDO_CL_SIGN_WAYBILL_LEDGER_RE4 ASSIGNING <EDO_CL_SIGN_WAYBILL_LEDGER_RE4>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<EDO_CL_SIGN_WAYBILL_LEDGER_RE4>-CONTROLLER = 1.
<EDO_CL_SIGN_WAYBILL_LEDGER_RE4>-ENVIO_LIBRO = 1.
<EDO_CL_SIGN_WAYBILL_LEDGER_RE4>-CONTROLLER = 1.
<EDO_CL_SIGN_WAYBILL_LEDGER_RE4>-CARATULA = 1.
<EDO_CL_SIGN_WAYBILL_LEDGER_RE4>-CONTROLLER = 1.
ENDLOOP. LOOP AT IT_EDO_CL_SIGN_WAYBILL_LEDGER_RE4 INTO WA_EDO_CL_SIGN_WAYBILL_LEDGER_RE4. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_EDO_CL_SIGN_WAYBILL_LEDGER_RE4-RUT_EMISOR_LIBRO, sy-vline,
WA_EDO_CL_SIGN_WAYBILL_LEDGER_RE4-RUT_ENVIA, sy-vline,
WA_EDO_CL_SIGN_WAYBILL_LEDGER_RE4-PERIODO_TRIBUTARIO, sy-vline,
WA_EDO_CL_SIGN_WAYBILL_LEDGER_RE4-FCH_RESOL, sy-vline,
WA_EDO_CL_SIGN_WAYBILL_LEDGER_RE4-NRO_RESOL, sy-vline,
WA_EDO_CL_SIGN_WAYBILL_LEDGER_RE4-TIPO_LIBRO, sy-vline.
ENDLOOP. *Add any further fields from structure WA_EDO_CL_SIGN_WAYBILL_LEDGER_RE4 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_EDO_CL_SIGN_WAYBILL_LEDGER_RE4 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_EDO_CL_SIGN_WAYBILL_LEDGER_RE4 INTO WA_EDO_CL_SIGN_WAYBILL_LEDGER_RE4. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_EDO_CL_SIGN_WAYBILL_LEDGER_RE4_STR,
CONTROLLER TYPE STRING,
ENVIO_LIBRO TYPE STRING,
CONTROLLER TYPE STRING,
CARATULA TYPE STRING,
CONTROLLER TYPE STRING,
RUT_EMISOR_LIBRO TYPE STRING,
RUT_ENVIA TYPE STRING,
PERIODO_TRIBUTARIO TYPE STRING,
FCH_RESOL TYPE STRING,
NRO_RESOL TYPE STRING,
TIPO_LIBRO TYPE STRING,
TIPO_ENVIO TYPE STRING,
NRO_SEGMENTO TYPE STRING,
FOLIO_NOTIFICACION TYPE STRING,
RESUMEN_SEGMENTO TYPE STRING,
CONTROLLER TYPE STRING,
TOT_FOL_ANULADO TYPE STRING,
TOT_GUIA_ANULADA TYPE STRING,
TOT_GUIA_VENTA TYPE STRING,
TOT_MNT_GUIA_VTA TYPE STRING,
TOT_MNT_MODIFICADO TYPE STRING,
TOT_TRASLADO TYPE STRING,
RESUMEN_PERIODO TYPE STRING,
CONTROLLER TYPE STRING,
TOT_FOL_ANULADO TYPE STRING,
TOT_GUIA_ANULADA TYPE STRING,
TOT_GUIA_VENTA TYPE STRING,
TOT_MNT_GUIA_VTA TYPE STRING,
TOT_MNT_MODIFICADO TYPE STRING,
TOT_TRASLADO TYPE STRING,
DETALLE TYPE STRING,
TMST_FIRMA TYPE STRING,
ID TYPE STRING,
VERSION TYPE STRING,END OF T_EKKO_STR. DATA: WA_EDO_CL_SIGN_WAYBILL_LEDGER_RE4_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_EDO_CL_SIGN_WAYBILL_LEDGER_RE4_STR-CONTROLLER sy-vline
WA_EDO_CL_SIGN_WAYBILL_LEDGER_RE4_STR-ENVIO_LIBRO sy-vline
WA_EDO_CL_SIGN_WAYBILL_LEDGER_RE4_STR-CONTROLLER sy-vline
WA_EDO_CL_SIGN_WAYBILL_LEDGER_RE4_STR-CARATULA sy-vline
WA_EDO_CL_SIGN_WAYBILL_LEDGER_RE4_STR-CONTROLLER sy-vline
WA_EDO_CL_SIGN_WAYBILL_LEDGER_RE4_STR-RUT_EMISOR_LIBRO sy-vline
WA_EDO_CL_SIGN_WAYBILL_LEDGER_RE4_STR-RUT_ENVIA sy-vline
WA_EDO_CL_SIGN_WAYBILL_LEDGER_RE4_STR-PERIODO_TRIBUTARIO sy-vline
WA_EDO_CL_SIGN_WAYBILL_LEDGER_RE4_STR-FCH_RESOL sy-vline
WA_EDO_CL_SIGN_WAYBILL_LEDGER_RE4_STR-NRO_RESOL sy-vline
WA_EDO_CL_SIGN_WAYBILL_LEDGER_RE4_STR-TIPO_LIBRO sy-vline
WA_EDO_CL_SIGN_WAYBILL_LEDGER_RE4_STR-TIPO_ENVIO sy-vline
WA_EDO_CL_SIGN_WAYBILL_LEDGER_RE4_STR-NRO_SEGMENTO sy-vline
WA_EDO_CL_SIGN_WAYBILL_LEDGER_RE4_STR-FOLIO_NOTIFICACION sy-vline
WA_EDO_CL_SIGN_WAYBILL_LEDGER_RE4_STR-RESUMEN_SEGMENTO sy-vline
WA_EDO_CL_SIGN_WAYBILL_LEDGER_RE4_STR-CONTROLLER sy-vline
WA_EDO_CL_SIGN_WAYBILL_LEDGER_RE4_STR-TOT_FOL_ANULADO sy-vline
WA_EDO_CL_SIGN_WAYBILL_LEDGER_RE4_STR-TOT_GUIA_ANULADA sy-vline
WA_EDO_CL_SIGN_WAYBILL_LEDGER_RE4_STR-TOT_GUIA_VENTA sy-vline
WA_EDO_CL_SIGN_WAYBILL_LEDGER_RE4_STR-TOT_MNT_GUIA_VTA sy-vline
WA_EDO_CL_SIGN_WAYBILL_LEDGER_RE4_STR-TOT_MNT_MODIFICADO sy-vline
WA_EDO_CL_SIGN_WAYBILL_LEDGER_RE4_STR-TOT_TRASLADO sy-vline
WA_EDO_CL_SIGN_WAYBILL_LEDGER_RE4_STR-RESUMEN_PERIODO sy-vline
WA_EDO_CL_SIGN_WAYBILL_LEDGER_RE4_STR-CONTROLLER sy-vline
WA_EDO_CL_SIGN_WAYBILL_LEDGER_RE4_STR-TOT_FOL_ANULADO sy-vline
WA_EDO_CL_SIGN_WAYBILL_LEDGER_RE4_STR-TOT_GUIA_ANULADA sy-vline
WA_EDO_CL_SIGN_WAYBILL_LEDGER_RE4_STR-TOT_GUIA_VENTA sy-vline
WA_EDO_CL_SIGN_WAYBILL_LEDGER_RE4_STR-TOT_MNT_GUIA_VTA sy-vline
WA_EDO_CL_SIGN_WAYBILL_LEDGER_RE4_STR-TOT_MNT_MODIFICADO sy-vline
WA_EDO_CL_SIGN_WAYBILL_LEDGER_RE4_STR-TOT_TRASLADO sy-vline
WA_EDO_CL_SIGN_WAYBILL_LEDGER_RE4_STR-DETALLE sy-vline
WA_EDO_CL_SIGN_WAYBILL_LEDGER_RE4_STR-TMST_FIRMA sy-vline
WA_EDO_CL_SIGN_WAYBILL_LEDGER_RE4_STR-ID sy-vline
WA_EDO_CL_SIGN_WAYBILL_LEDGER_RE4_STR-VERSION sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.