ABAP Select data from SAP table EHFNDS_EHS_BAPI1077PACK into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP EHFNDS_EHS_BAPI1077PACK table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to EHFNDS_EHS_BAPI1077PACK. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the EHFNDS_EHS_BAPI1077PACK table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_EHFNDS_EHS_BAPI1077PACK TYPE STANDARD TABLE OF EHFNDS_EHS_BAPI1077PACK, WA_EHFNDS_EHS_BAPI1077PACK TYPE EHFNDS_EHS_BAPI1077PACK, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <EHFNDS_EHS_BAPI1077PACK> TYPE EHFNDS_EHS_BAPI1077PACK. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_EHFNDS_EHS_BAPI1077PACK. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM EHFNDS_EHS_BAPI1077PACK INTO TABLE IT_EHFNDS_EHS_BAPI1077PACK. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM EHFNDS_EHS_BAPI1077PACK * INTO TABLE @DATA(IT_EHFNDS_EHS_BAPI1077PACK2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_EHFNDS_EHS_BAPI1077PACK INDEX 1 INTO DATA(WA_EHFNDS_EHS_BAPI1077PACK2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_EHFNDS_EHS_BAPI1077PACK ASSIGNING <EHFNDS_EHS_BAPI1077PACK>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<EHFNDS_EHS_BAPI1077PACK>-FUNCTION = 1.
<EHFNDS_EHS_BAPI1077PACK>-LOGLOCKMOD = 1.
<EHFNDS_EHS_BAPI1077PACK>-EXTINFO = 1.
<EHFNDS_EHS_BAPI1077PACK>-PRIMARYKEY = 1.
<EHFNDS_EHS_BAPI1077PACK>-FOREIGNKEY = 1.
ENDLOOP. LOOP AT IT_EHFNDS_EHS_BAPI1077PACK INTO WA_EHFNDS_EHS_BAPI1077PACK. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_EHFNDS_EHS_BAPI1077PACK-FLGPRIMKEY, sy-vline,
WA_EHFNDS_EHS_BAPI1077PACK-FLGFRGNKEY, sy-vline,
WA_EHFNDS_EHS_BAPI1077PACK-CLIENT, sy-vline,
WA_EHFNDS_EHS_BAPI1077PACK-RECORD_NO, sy-vline,
WA_EHFNDS_EHS_BAPI1077PACK-CHNGSTATUS, sy-vline,
WA_EHFNDS_EHS_BAPI1077PACK-VALID_FROM, sy-vline.
ENDLOOP. *Add any further fields from structure WA_EHFNDS_EHS_BAPI1077PACK you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_EHFNDS_EHS_BAPI1077PACK TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_EHFNDS_EHS_BAPI1077PACK INTO WA_EHFNDS_EHS_BAPI1077PACK. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ALPHA, internal->external for field RECORD_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EHFNDS_EHS_BAPI1077PACK-RECORD_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHFNDS_EHS_BAPI1077PACK-RECORD_NO.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field CHNGSTATUS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EHFNDS_EHS_BAPI1077PACK-CHNGSTATUS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHFNDS_EHS_BAPI1077PACK-CHNGSTATUS.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field CHANG_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EHFNDS_EHS_BAPI1077PACK-CHANG_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHFNDS_EHS_BAPI1077PACK-CHANG_NO.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field DATA_PROV CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EHFNDS_EHS_BAPI1077PACK-DATA_PROV IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHFNDS_EHS_BAPI1077PACK-DATA_PROV.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field RECNO_ROOT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EHFNDS_EHS_BAPI1077PACK-RECNO_ROOT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHFNDS_EHS_BAPI1077PACK-RECNO_ROOT.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field REF_RECN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EHFNDS_EHS_BAPI1077PACK-REF_RECN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHFNDS_EHS_BAPI1077PACK-REF_RECN.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field UNIT_MAXIP CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_EHFNDS_EHS_BAPI1077PACK-UNIT_MAXIP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHFNDS_EHS_BAPI1077PACK-UNIT_MAXIP.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field UNIT_MAXOP CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_EHFNDS_EHS_BAPI1077PACK-UNIT_MAXOP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHFNDS_EHS_BAPI1077PACK-UNIT_MAXOP.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field UNIT_MAXSP CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_EHFNDS_EHS_BAPI1077PACK-UNIT_MAXSP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHFNDS_EHS_BAPI1077PACK-UNIT_MAXSP.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field UNIT_GRWGT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_EHFNDS_EHS_BAPI1077PACK-UNIT_GRWGT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHFNDS_EHS_BAPI1077PACK-UNIT_GRWGT.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field REF_RECNRH CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EHFNDS_EHS_BAPI1077PACK-REF_RECNRH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHFNDS_EHS_BAPI1077PACK-REF_RECNRH.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_EHFNDS_EHS_BAPI1077PACK_STR,
FUNCTION TYPE STRING,
LOGLOCKMOD TYPE STRING,
EXTINFO TYPE STRING,
PRIMARYKEY TYPE STRING,
FOREIGNKEY TYPE STRING,
FLGPRIMKEY TYPE STRING,
FLGFRGNKEY TYPE STRING,
CLIENT TYPE STRING,
RECORD_NO TYPE STRING,
CHNGSTATUS TYPE STRING,
VALID_FROM TYPE STRING,
VALID_TO TYPE STRING,
CHANG_NO TYPE STRING,
DEL_IND TYPE STRING,
PARK_IND TYPE STRING,
CREATED_ON TYPE STRING,
CREATED_BY TYPE STRING,
CHANGD_ON TYPE STRING,
CHANGD_BY TYPE STRING,
DATAORIGIN TYPE STRING,
DATA_PROV TYPE STRING,
RECNO_ROOT TYPE STRING,
REF_RECN TYPE STRING,
RISK_POT TYPE STRING,
INSTRUCT_ENCLOSURE TYPE STRING,
PACK_CODE_IN TYPE STRING,
PACK_CODE_OUT TYPE STRING,
PACK_CODE_SGL TYPE STRING,
IPACK_MAX TYPE STRING,
UNIT_MAXIP TYPE STRING,
UISO_MAXIP TYPE STRING,
FLAG_IPACK_MAX TYPE STRING,
OPACK_MAX TYPE STRING,
UNIT_MAXOP TYPE STRING,
UISO_MAXOP TYPE STRING,
FLAG_OPACK_MAX TYPE STRING,
SPACK_MAX TYPE STRING,
UNIT_MAXSP TYPE STRING,
UISO_MAXSP TYPE STRING,
FLAG_SPACK_MAX TYPE STRING,
GR_WEIGHT TYPE STRING,
UNIT_GRWGT TYPE STRING,
UISO_GRWGT TYPE STRING,
FLAG_GR_WEIGHT TYPE STRING,
PALETTE TYPE STRING,
AGREE_AUTH TYPE STRING,
REF_RECNRH TYPE STRING,END OF T_EKKO_STR. DATA: WA_EHFNDS_EHS_BAPI1077PACK_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_EHFNDS_EHS_BAPI1077PACK_STR-FUNCTION sy-vline
WA_EHFNDS_EHS_BAPI1077PACK_STR-LOGLOCKMOD sy-vline
WA_EHFNDS_EHS_BAPI1077PACK_STR-EXTINFO sy-vline
WA_EHFNDS_EHS_BAPI1077PACK_STR-PRIMARYKEY sy-vline
WA_EHFNDS_EHS_BAPI1077PACK_STR-FOREIGNKEY sy-vline
WA_EHFNDS_EHS_BAPI1077PACK_STR-FLGPRIMKEY sy-vline
WA_EHFNDS_EHS_BAPI1077PACK_STR-FLGFRGNKEY sy-vline
WA_EHFNDS_EHS_BAPI1077PACK_STR-CLIENT sy-vline
WA_EHFNDS_EHS_BAPI1077PACK_STR-RECORD_NO sy-vline
WA_EHFNDS_EHS_BAPI1077PACK_STR-CHNGSTATUS sy-vline
WA_EHFNDS_EHS_BAPI1077PACK_STR-VALID_FROM sy-vline
WA_EHFNDS_EHS_BAPI1077PACK_STR-VALID_TO sy-vline
WA_EHFNDS_EHS_BAPI1077PACK_STR-CHANG_NO sy-vline
WA_EHFNDS_EHS_BAPI1077PACK_STR-DEL_IND sy-vline
WA_EHFNDS_EHS_BAPI1077PACK_STR-PARK_IND sy-vline
WA_EHFNDS_EHS_BAPI1077PACK_STR-CREATED_ON sy-vline
WA_EHFNDS_EHS_BAPI1077PACK_STR-CREATED_BY sy-vline
WA_EHFNDS_EHS_BAPI1077PACK_STR-CHANGD_ON sy-vline
WA_EHFNDS_EHS_BAPI1077PACK_STR-CHANGD_BY sy-vline
WA_EHFNDS_EHS_BAPI1077PACK_STR-DATAORIGIN sy-vline
WA_EHFNDS_EHS_BAPI1077PACK_STR-DATA_PROV sy-vline
WA_EHFNDS_EHS_BAPI1077PACK_STR-RECNO_ROOT sy-vline
WA_EHFNDS_EHS_BAPI1077PACK_STR-REF_RECN sy-vline
WA_EHFNDS_EHS_BAPI1077PACK_STR-RISK_POT sy-vline
WA_EHFNDS_EHS_BAPI1077PACK_STR-INSTRUCT_ENCLOSURE sy-vline
WA_EHFNDS_EHS_BAPI1077PACK_STR-PACK_CODE_IN sy-vline
WA_EHFNDS_EHS_BAPI1077PACK_STR-PACK_CODE_OUT sy-vline
WA_EHFNDS_EHS_BAPI1077PACK_STR-PACK_CODE_SGL sy-vline
WA_EHFNDS_EHS_BAPI1077PACK_STR-IPACK_MAX sy-vline
WA_EHFNDS_EHS_BAPI1077PACK_STR-UNIT_MAXIP sy-vline
WA_EHFNDS_EHS_BAPI1077PACK_STR-UISO_MAXIP sy-vline
WA_EHFNDS_EHS_BAPI1077PACK_STR-FLAG_IPACK_MAX sy-vline
WA_EHFNDS_EHS_BAPI1077PACK_STR-OPACK_MAX sy-vline
WA_EHFNDS_EHS_BAPI1077PACK_STR-UNIT_MAXOP sy-vline
WA_EHFNDS_EHS_BAPI1077PACK_STR-UISO_MAXOP sy-vline
WA_EHFNDS_EHS_BAPI1077PACK_STR-FLAG_OPACK_MAX sy-vline
WA_EHFNDS_EHS_BAPI1077PACK_STR-SPACK_MAX sy-vline
WA_EHFNDS_EHS_BAPI1077PACK_STR-UNIT_MAXSP sy-vline
WA_EHFNDS_EHS_BAPI1077PACK_STR-UISO_MAXSP sy-vline
WA_EHFNDS_EHS_BAPI1077PACK_STR-FLAG_SPACK_MAX sy-vline
WA_EHFNDS_EHS_BAPI1077PACK_STR-GR_WEIGHT sy-vline
WA_EHFNDS_EHS_BAPI1077PACK_STR-UNIT_GRWGT sy-vline
WA_EHFNDS_EHS_BAPI1077PACK_STR-UISO_GRWGT sy-vline
WA_EHFNDS_EHS_BAPI1077PACK_STR-FLAG_GR_WEIGHT sy-vline
WA_EHFNDS_EHS_BAPI1077PACK_STR-PALETTE sy-vline
WA_EHFNDS_EHS_BAPI1077PACK_STR-AGREE_AUTH sy-vline
WA_EHFNDS_EHS_BAPI1077PACK_STR-REF_RECNRH sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.