ABAP Select data from SAP table EHFNDS_HSP_T7EHS00_PROT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP EHFNDS_HSP_T7EHS00_PROT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to EHFNDS_HSP_T7EHS00_PROT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the EHFNDS_HSP_T7EHS00_PROT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_EHFNDS_HSP_T7EHS00_PROT TYPE STANDARD TABLE OF EHFNDS_HSP_T7EHS00_PROT,
      WA_EHFNDS_HSP_T7EHS00_PROT TYPE EHFNDS_HSP_T7EHS00_PROT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <EHFNDS_HSP_T7EHS00_PROT> TYPE EHFNDS_HSP_T7EHS00_PROT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_EHFNDS_HSP_T7EHS00_PROT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM EHFNDS_HSP_T7EHS00_PROT
  INTO TABLE IT_EHFNDS_HSP_T7EHS00_PROT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM EHFNDS_HSP_T7EHS00_PROT
*  INTO TABLE @DATA(IT_EHFNDS_HSP_T7EHS00_PROT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_EHFNDS_HSP_T7EHS00_PROT INDEX 1 INTO DATA(WA_EHFNDS_HSP_T7EHS00_PROT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_EHFNDS_HSP_T7EHS00_PROT ASSIGNING <EHFNDS_HSP_T7EHS00_PROT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<EHFNDS_HSP_T7EHS00_PROT>-MANDT = 1.
<EHFNDS_HSP_T7EHS00_PROT>-PGROUP = 1.
<EHFNDS_HSP_T7EHS00_PROT>-PNUMBER = 1.
<EHFNDS_HSP_T7EHS00_PROT>-ENDDA = 1.
<EHFNDS_HSP_T7EHS00_PROT>-BEGDA = 1.
ENDLOOP.

LOOP AT IT_EHFNDS_HSP_T7EHS00_PROT INTO WA_EHFNDS_HSP_T7EHS00_PROT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_EHFNDS_HSP_T7EHS00_PROT-POWNER, sy-vline,
WA_EHFNDS_HSP_T7EHS00_PROT-LTEXT, sy-vline,
WA_EHFNDS_HSP_T7EHS00_PROT-AEDTM, sy-vline,
WA_EHFNDS_HSP_T7EHS00_PROT-UNAME, sy-vline,
WA_EHFNDS_HSP_T7EHS00_PROT-REGULATORY, sy-vline,
WA_EHFNDS_HSP_T7EHS00_PROT-MANDATORY, sy-vline.
ENDLOOP. *Add any further fields from structure WA_EHFNDS_HSP_T7EHS00_PROT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_EHFNDS_HSP_T7EHS00_PROT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_EHFNDS_HSP_T7EHS00_PROT INTO WA_EHFNDS_HSP_T7EHS00_PROT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field AENNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EHFNDS_HSP_T7EHS00_PROT-AENNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHFNDS_HSP_T7EHS00_PROT-AENNR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_EHFNDS_HSP_T7EHS00_PROT_STR,
MANDT TYPE STRING,
PGROUP TYPE STRING,
PNUMBER TYPE STRING,
ENDDA TYPE STRING,
BEGDA TYPE STRING,
POWNER TYPE STRING,
LTEXT TYPE STRING,
AEDTM TYPE STRING,
UNAME TYPE STRING,
REGULATORY TYPE STRING,
MANDATORY TYPE STRING,
SCHEDNR TYPE STRING,
LTA_TRIGGER TYPE STRING,
NRT_TRIGGER TYPE STRING,
AND_LTA_TRIGGER TYPE STRING,
ER_RAT_TRIG TYPE STRING,
ER_RAT_FREQ_TRIG TYPE STRING,
SKINEXPFREQ_TRIG TYPE STRING,
SKINEFFFREQ_TRIG TYPE STRING,
INGESTFREQ_TRIG TYPE STRING,
ALWAYS_CHECK TYPE STRING,
COST_INT TYPE STRING,
COST_EXT TYPE STRING,
WAEHR_INT TYPE STRING,
WAEHR_EXT TYPE STRING,
DURATION_INT TYPE STRING,
DURATION_EXT TYPE STRING,
STATUS TYPE STRING,
ACTIV_INACTIVE TYPE STRING,
FREQ_FULL_RV_EX TYPE STRING,
FREQ_ACT_LEV_EX TYPE STRING,
AGE_FROM TYPE STRING,
AGE_TO TYPE STRING,
CANCER_RELATED TYPE STRING,
AENNR TYPE STRING,
CRNAM TYPE STRING,
CRDTIMESTAMP TYPE STRING,
UPDNAM TYPE STRING,
UPDTIMESTAMP TYPE STRING,
GENDER TYPE STRING,
REASON_COMB TYPE STRING,END OF T_EKKO_STR. DATA: WA_EHFNDS_HSP_T7EHS00_PROT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_EHFNDS_HSP_T7EHS00_PROT_STR-MANDT sy-vline
WA_EHFNDS_HSP_T7EHS00_PROT_STR-PGROUP sy-vline
WA_EHFNDS_HSP_T7EHS00_PROT_STR-PNUMBER sy-vline
WA_EHFNDS_HSP_T7EHS00_PROT_STR-ENDDA sy-vline
WA_EHFNDS_HSP_T7EHS00_PROT_STR-BEGDA sy-vline
WA_EHFNDS_HSP_T7EHS00_PROT_STR-POWNER sy-vline
WA_EHFNDS_HSP_T7EHS00_PROT_STR-LTEXT sy-vline
WA_EHFNDS_HSP_T7EHS00_PROT_STR-AEDTM sy-vline
WA_EHFNDS_HSP_T7EHS00_PROT_STR-UNAME sy-vline
WA_EHFNDS_HSP_T7EHS00_PROT_STR-REGULATORY sy-vline
WA_EHFNDS_HSP_T7EHS00_PROT_STR-MANDATORY sy-vline
WA_EHFNDS_HSP_T7EHS00_PROT_STR-SCHEDNR sy-vline
WA_EHFNDS_HSP_T7EHS00_PROT_STR-LTA_TRIGGER sy-vline
WA_EHFNDS_HSP_T7EHS00_PROT_STR-NRT_TRIGGER sy-vline
WA_EHFNDS_HSP_T7EHS00_PROT_STR-AND_LTA_TRIGGER sy-vline
WA_EHFNDS_HSP_T7EHS00_PROT_STR-ER_RAT_TRIG sy-vline
WA_EHFNDS_HSP_T7EHS00_PROT_STR-ER_RAT_FREQ_TRIG sy-vline
WA_EHFNDS_HSP_T7EHS00_PROT_STR-SKINEXPFREQ_TRIG sy-vline
WA_EHFNDS_HSP_T7EHS00_PROT_STR-SKINEFFFREQ_TRIG sy-vline
WA_EHFNDS_HSP_T7EHS00_PROT_STR-INGESTFREQ_TRIG sy-vline
WA_EHFNDS_HSP_T7EHS00_PROT_STR-ALWAYS_CHECK sy-vline
WA_EHFNDS_HSP_T7EHS00_PROT_STR-COST_INT sy-vline
WA_EHFNDS_HSP_T7EHS00_PROT_STR-COST_EXT sy-vline
WA_EHFNDS_HSP_T7EHS00_PROT_STR-WAEHR_INT sy-vline
WA_EHFNDS_HSP_T7EHS00_PROT_STR-WAEHR_EXT sy-vline
WA_EHFNDS_HSP_T7EHS00_PROT_STR-DURATION_INT sy-vline
WA_EHFNDS_HSP_T7EHS00_PROT_STR-DURATION_EXT sy-vline
WA_EHFNDS_HSP_T7EHS00_PROT_STR-STATUS sy-vline
WA_EHFNDS_HSP_T7EHS00_PROT_STR-ACTIV_INACTIVE sy-vline
WA_EHFNDS_HSP_T7EHS00_PROT_STR-FREQ_FULL_RV_EX sy-vline
WA_EHFNDS_HSP_T7EHS00_PROT_STR-FREQ_ACT_LEV_EX sy-vline
WA_EHFNDS_HSP_T7EHS00_PROT_STR-AGE_FROM sy-vline
WA_EHFNDS_HSP_T7EHS00_PROT_STR-AGE_TO sy-vline
WA_EHFNDS_HSP_T7EHS00_PROT_STR-CANCER_RELATED sy-vline
WA_EHFNDS_HSP_T7EHS00_PROT_STR-AENNR sy-vline
WA_EHFNDS_HSP_T7EHS00_PROT_STR-CRNAM sy-vline
WA_EHFNDS_HSP_T7EHS00_PROT_STR-CRDTIMESTAMP sy-vline
WA_EHFNDS_HSP_T7EHS00_PROT_STR-UPDNAM sy-vline
WA_EHFNDS_HSP_T7EHS00_PROT_STR-UPDTIMESTAMP sy-vline
WA_EHFNDS_HSP_T7EHS00_PROT_STR-GENDER sy-vline
WA_EHFNDS_HSP_T7EHS00_PROT_STR-REASON_COMB sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.