ABAP Select data from SAP table EHFNDS_MCWF_TRANS into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP EHFNDS_MCWF_TRANS table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to EHFNDS_MCWF_TRANS. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the EHFNDS_MCWF_TRANS table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_EHFNDS_MCWF_TRANS TYPE STANDARD TABLE OF EHFNDS_MCWF_TRANS, WA_EHFNDS_MCWF_TRANS TYPE EHFNDS_MCWF_TRANS, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <EHFNDS_MCWF_TRANS> TYPE EHFNDS_MCWF_TRANS. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_EHFNDS_MCWF_TRANS. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM EHFNDS_MCWF_TRANS INTO TABLE IT_EHFNDS_MCWF_TRANS. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM EHFNDS_MCWF_TRANS * INTO TABLE @DATA(IT_EHFNDS_MCWF_TRANS2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_EHFNDS_MCWF_TRANS INDEX 1 INTO DATA(WA_EHFNDS_MCWF_TRANS2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_EHFNDS_MCWF_TRANS ASSIGNING <EHFNDS_MCWF_TRANS>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<EHFNDS_MCWF_TRANS>-CLIENT = 1.
<EHFNDS_MCWF_TRANS>-WI_ID = 1.
<EHFNDS_MCWF_TRANS>-WI_TYPE = 1.
<EHFNDS_MCWF_TRANS>-WI_CREATOR = 1.
<EHFNDS_MCWF_TRANS>-WI_LANG = 1.
ENDLOOP. LOOP AT IT_EHFNDS_MCWF_TRANS INTO WA_EHFNDS_MCWF_TRANS. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_EHFNDS_MCWF_TRANS-WI_TEXT, sy-vline,
WA_EHFNDS_MCWF_TRANS-WI_RHTEXT, sy-vline,
WA_EHFNDS_MCWF_TRANS-WI_STAT, sy-vline,
WA_EHFNDS_MCWF_TRANS-WI_CD, sy-vline,
WA_EHFNDS_MCWF_TRANS-WI_CT, sy-vline,
WA_EHFNDS_MCWF_TRANS-WI_AED, sy-vline.
ENDLOOP. *Add any further fields from structure WA_EHFNDS_MCWF_TRANS you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_EHFNDS_MCWF_TRANS TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_EHFNDS_MCWF_TRANS INTO WA_EHFNDS_MCWF_TRANS. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ISOLA, internal->external for field WI_LANG CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_EHFNDS_MCWF_TRANS-WI_LANG IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHFNDS_MCWF_TRANS-WI_LANG.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field TCLASS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EHFNDS_MCWF_TRANS-TCLASS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHFNDS_MCWF_TRANS-TCLASS.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field REMOTE_SYS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EHFNDS_MCWF_TRANS-REMOTE_SYS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHFNDS_MCWF_TRANS-REMOTE_SYS.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field UNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_EHFNDS_MCWF_TRANS-UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHFNDS_MCWF_TRANS-UNIT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_EHFNDS_MCWF_TRANS_STR,
CLIENT TYPE STRING,
WI_ID TYPE STRING,
WI_TYPE TYPE STRING,
WI_CREATOR TYPE STRING,
WI_LANG TYPE STRING,
WI_TEXT TYPE STRING,
WI_RHTEXT TYPE STRING,
WI_STAT TYPE STRING,
WI_CD TYPE STRING,
WI_CT TYPE STRING,
WI_AED TYPE STRING,
WI_AAGENT TYPE STRING,
WI_AADDR TYPE STRING,
WI_CRUSER TYPE STRING,
WI_CRADDR TYPE STRING,
WI_CHCKWI TYPE STRING,
WI_CBFB TYPE STRING,
WI_RH_TASK TYPE STRING,
WI_PRIO TYPE STRING,
WI_CONFIRM TYPE STRING,
WI_COMP_EV TYPE STRING,
WI_FORW_BY TYPE STRING,
WI_DISABLE TYPE STRING,
WI_REJECT TYPE STRING,
TCLASS TYPE STRING,
NOTE_EXIST TYPE STRING,
NOTIFY TYPE STRING,
RETRY_CNT TYPE STRING,
MAX_RETRY TYPE STRING,
RC_MODELED TYPE STRING,
CB_DONE TYPE STRING,
HANDLE TYPE STRING,
SYNCCHAIN TYPE STRING,
NO_DEADL TYPE STRING,
WI_DH_STAT TYPE STRING,
WI_RELEASE TYPE STRING,
WLC_DISPL TYPE STRING,
WI_RESTLOG TYPE STRING,
REMOTE_ID TYPE STRING,
REMOTE_SYS TYPE STRING,
STATUS_EVT TYPE STRING,
TIMEOUT TYPE STRING,
WF_TYPE TYPE STRING,
WLC_FLAGS TYPE STRING,
XMLPROT TYPE STRING,
WAIT4CB TYPE STRING,
TOP_WI_ID TYPE STRING,
DEF_GUID TYPE STRING,
EXEC_TIME TYPE STRING,
NOTE_COUNT TYPE STRING,
PRS_PROFIL TYPE STRING,
CREA_TMP TYPE STRING,
CHECK_STAT TYPE STRING,
BLOCKTYPE TYPE STRING,
PARENT_WI TYPE STRING,
RNDNUMBER TYPE STRING,
WFD_ID TYPE STRING,
WFD_VERSION TYPE STRING,
WFD_EXETYP TYPE STRING,
PROCCAT TYPE STRING,
TOP_TASK TYPE STRING,
AGING_STATE TYPE STRING,
AGING_TEMPERATURE TYPE STRING,
WLC_FLAGS_EXT TYPE STRING,
WI_AED_TIMESTAMP TYPE STRING,
REFERENCE_NODEID TYPE STRING,
STEP_ID TYPE STRING,
AGENT_RULE_ID TYPE STRING,
WI_TEXT_ID TYPE STRING,
CPWF_HANDLE TYPE STRING,
WI_MOD_TIMESTAMP TYPE STRING,
WI_MOD_BY TYPE STRING,
TIME_TOTAL TYPE STRING,
TIME_MEAN TYPE STRING,
TIME_SIGMA TYPE STRING,
TAR_TOTAL TYPE STRING,
TAR_MEAN TYPE STRING,
TAR_SQUARE TYPE STRING,
TAR_SIGMA TYPE STRING,
NET_TOTAL TYPE STRING,
NET_MEAN TYPE STRING,
NET_SQUARE TYPE STRING,
NET_SIGMA TYPE STRING,
UNIT TYPE STRING,
PROCSTATE TYPE STRING,
CREATEDBY TYPE STRING,
APPROVBY TYPE STRING,
WI_ORGUNIT TYPE STRING,
WI_ROOT TYPE STRING,
WI_FLOW TYPE STRING,
WI_OBJ_TYP TYPE STRING,
WI_OBJECT TYPE STRING,
WI_GRP_TYP TYPE STRING,
WI_GROUP TYPE STRING,
WI_COUNT TYPE STRING,
WI_FRACT TYPE STRING,END OF T_EKKO_STR. DATA: WA_EHFNDS_MCWF_TRANS_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_EHFNDS_MCWF_TRANS_STR-CLIENT sy-vline
WA_EHFNDS_MCWF_TRANS_STR-WI_ID sy-vline
WA_EHFNDS_MCWF_TRANS_STR-WI_TYPE sy-vline
WA_EHFNDS_MCWF_TRANS_STR-WI_CREATOR sy-vline
WA_EHFNDS_MCWF_TRANS_STR-WI_LANG sy-vline
WA_EHFNDS_MCWF_TRANS_STR-WI_TEXT sy-vline
WA_EHFNDS_MCWF_TRANS_STR-WI_RHTEXT sy-vline
WA_EHFNDS_MCWF_TRANS_STR-WI_STAT sy-vline
WA_EHFNDS_MCWF_TRANS_STR-WI_CD sy-vline
WA_EHFNDS_MCWF_TRANS_STR-WI_CT sy-vline
WA_EHFNDS_MCWF_TRANS_STR-WI_AED sy-vline
WA_EHFNDS_MCWF_TRANS_STR-WI_AAGENT sy-vline
WA_EHFNDS_MCWF_TRANS_STR-WI_AADDR sy-vline
WA_EHFNDS_MCWF_TRANS_STR-WI_CRUSER sy-vline
WA_EHFNDS_MCWF_TRANS_STR-WI_CRADDR sy-vline
WA_EHFNDS_MCWF_TRANS_STR-WI_CHCKWI sy-vline
WA_EHFNDS_MCWF_TRANS_STR-WI_CBFB sy-vline
WA_EHFNDS_MCWF_TRANS_STR-WI_RH_TASK sy-vline
WA_EHFNDS_MCWF_TRANS_STR-WI_PRIO sy-vline
WA_EHFNDS_MCWF_TRANS_STR-WI_CONFIRM sy-vline
WA_EHFNDS_MCWF_TRANS_STR-WI_COMP_EV sy-vline
WA_EHFNDS_MCWF_TRANS_STR-WI_FORW_BY sy-vline
WA_EHFNDS_MCWF_TRANS_STR-WI_DISABLE sy-vline
WA_EHFNDS_MCWF_TRANS_STR-WI_REJECT sy-vline
WA_EHFNDS_MCWF_TRANS_STR-TCLASS sy-vline
WA_EHFNDS_MCWF_TRANS_STR-NOTE_EXIST sy-vline
WA_EHFNDS_MCWF_TRANS_STR-NOTIFY sy-vline
WA_EHFNDS_MCWF_TRANS_STR-RETRY_CNT sy-vline
WA_EHFNDS_MCWF_TRANS_STR-MAX_RETRY sy-vline
WA_EHFNDS_MCWF_TRANS_STR-RC_MODELED sy-vline
WA_EHFNDS_MCWF_TRANS_STR-CB_DONE sy-vline
WA_EHFNDS_MCWF_TRANS_STR-HANDLE sy-vline
WA_EHFNDS_MCWF_TRANS_STR-SYNCCHAIN sy-vline
WA_EHFNDS_MCWF_TRANS_STR-NO_DEADL sy-vline
WA_EHFNDS_MCWF_TRANS_STR-WI_DH_STAT sy-vline
WA_EHFNDS_MCWF_TRANS_STR-WI_RELEASE sy-vline
WA_EHFNDS_MCWF_TRANS_STR-WLC_DISPL sy-vline
WA_EHFNDS_MCWF_TRANS_STR-WI_RESTLOG sy-vline
WA_EHFNDS_MCWF_TRANS_STR-REMOTE_ID sy-vline
WA_EHFNDS_MCWF_TRANS_STR-REMOTE_SYS sy-vline
WA_EHFNDS_MCWF_TRANS_STR-STATUS_EVT sy-vline
WA_EHFNDS_MCWF_TRANS_STR-TIMEOUT sy-vline
WA_EHFNDS_MCWF_TRANS_STR-WF_TYPE sy-vline
WA_EHFNDS_MCWF_TRANS_STR-WLC_FLAGS sy-vline
WA_EHFNDS_MCWF_TRANS_STR-XMLPROT sy-vline
WA_EHFNDS_MCWF_TRANS_STR-WAIT4CB sy-vline
WA_EHFNDS_MCWF_TRANS_STR-TOP_WI_ID sy-vline
WA_EHFNDS_MCWF_TRANS_STR-DEF_GUID sy-vline
WA_EHFNDS_MCWF_TRANS_STR-EXEC_TIME sy-vline
WA_EHFNDS_MCWF_TRANS_STR-NOTE_COUNT sy-vline
WA_EHFNDS_MCWF_TRANS_STR-PRS_PROFIL sy-vline
WA_EHFNDS_MCWF_TRANS_STR-CREA_TMP sy-vline
WA_EHFNDS_MCWF_TRANS_STR-CHECK_STAT sy-vline
WA_EHFNDS_MCWF_TRANS_STR-BLOCKTYPE sy-vline
WA_EHFNDS_MCWF_TRANS_STR-PARENT_WI sy-vline
WA_EHFNDS_MCWF_TRANS_STR-RNDNUMBER sy-vline
WA_EHFNDS_MCWF_TRANS_STR-WFD_ID sy-vline
WA_EHFNDS_MCWF_TRANS_STR-WFD_VERSION sy-vline
WA_EHFNDS_MCWF_TRANS_STR-WFD_EXETYP sy-vline
WA_EHFNDS_MCWF_TRANS_STR-PROCCAT sy-vline
WA_EHFNDS_MCWF_TRANS_STR-TOP_TASK sy-vline
WA_EHFNDS_MCWF_TRANS_STR-AGING_STATE sy-vline
WA_EHFNDS_MCWF_TRANS_STR-AGING_TEMPERATURE sy-vline
WA_EHFNDS_MCWF_TRANS_STR-WLC_FLAGS_EXT sy-vline
WA_EHFNDS_MCWF_TRANS_STR-WI_AED_TIMESTAMP sy-vline
WA_EHFNDS_MCWF_TRANS_STR-REFERENCE_NODEID sy-vline
WA_EHFNDS_MCWF_TRANS_STR-STEP_ID sy-vline
WA_EHFNDS_MCWF_TRANS_STR-AGENT_RULE_ID sy-vline
WA_EHFNDS_MCWF_TRANS_STR-WI_TEXT_ID sy-vline
WA_EHFNDS_MCWF_TRANS_STR-CPWF_HANDLE sy-vline
WA_EHFNDS_MCWF_TRANS_STR-WI_MOD_TIMESTAMP sy-vline
WA_EHFNDS_MCWF_TRANS_STR-WI_MOD_BY sy-vline
WA_EHFNDS_MCWF_TRANS_STR-TIME_TOTAL sy-vline
WA_EHFNDS_MCWF_TRANS_STR-TIME_MEAN sy-vline
WA_EHFNDS_MCWF_TRANS_STR-TIME_SIGMA sy-vline
WA_EHFNDS_MCWF_TRANS_STR-TAR_TOTAL sy-vline
WA_EHFNDS_MCWF_TRANS_STR-TAR_MEAN sy-vline
WA_EHFNDS_MCWF_TRANS_STR-TAR_SQUARE sy-vline
WA_EHFNDS_MCWF_TRANS_STR-TAR_SIGMA sy-vline
WA_EHFNDS_MCWF_TRANS_STR-NET_TOTAL sy-vline
WA_EHFNDS_MCWF_TRANS_STR-NET_MEAN sy-vline
WA_EHFNDS_MCWF_TRANS_STR-NET_SQUARE sy-vline
WA_EHFNDS_MCWF_TRANS_STR-NET_SIGMA sy-vline
WA_EHFNDS_MCWF_TRANS_STR-UNIT sy-vline
WA_EHFNDS_MCWF_TRANS_STR-PROCSTATE sy-vline
WA_EHFNDS_MCWF_TRANS_STR-CREATEDBY sy-vline
WA_EHFNDS_MCWF_TRANS_STR-APPROVBY sy-vline
WA_EHFNDS_MCWF_TRANS_STR-WI_ORGUNIT sy-vline
WA_EHFNDS_MCWF_TRANS_STR-WI_ROOT sy-vline
WA_EHFNDS_MCWF_TRANS_STR-WI_FLOW sy-vline
WA_EHFNDS_MCWF_TRANS_STR-WI_OBJ_TYP sy-vline
WA_EHFNDS_MCWF_TRANS_STR-WI_OBJECT sy-vline
WA_EHFNDS_MCWF_TRANS_STR-WI_GRP_TYP sy-vline
WA_EHFNDS_MCWF_TRANS_STR-WI_GROUP sy-vline
WA_EHFNDS_MCWF_TRANS_STR-WI_COUNT sy-vline
WA_EHFNDS_MCWF_TRANS_STR-WI_FRACT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.