ABAP Select data from SAP table EHFNDS_TM_CRITERIA_INTERNAL into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP EHFNDS_TM_CRITERIA_INTERNAL table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to EHFNDS_TM_CRITERIA_INTERNAL. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the EHFNDS_TM_CRITERIA_INTERNAL table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_EHFNDS_TM_CRITERIA_INTERNAL TYPE STANDARD TABLE OF EHFNDS_TM_CRITERIA_INTERNAL,
      WA_EHFNDS_TM_CRITERIA_INTERNAL TYPE EHFNDS_TM_CRITERIA_INTERNAL,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <EHFNDS_TM_CRITERIA_INTERNAL> TYPE EHFNDS_TM_CRITERIA_INTERNAL.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_EHFNDS_TM_CRITERIA_INTERNAL.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM EHFNDS_TM_CRITERIA_INTERNAL
  INTO TABLE IT_EHFNDS_TM_CRITERIA_INTERNAL.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM EHFNDS_TM_CRITERIA_INTERNAL
*  INTO TABLE @DATA(IT_EHFNDS_TM_CRITERIA_INTERNAL2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_EHFNDS_TM_CRITERIA_INTERNAL INDEX 1 INTO DATA(WA_EHFNDS_TM_CRITERIA_INTERNAL2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_EHFNDS_TM_CRITERIA_INTERNAL ASSIGNING <EHFNDS_TM_CRITERIA_INTERNAL>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<EHFNDS_TM_CRITERIA_INTERNAL>-EHSM_COMPONENT = 1.
<EHFNDS_TM_CRITERIA_INTERNAL>-TASK_INITIATED_BY = 1.
<EHFNDS_TM_CRITERIA_INTERNAL>-PROCESSOR = 1.
<EHFNDS_TM_CRITERIA_INTERNAL>-PROCESSOR_RANGE = 1.
<EHFNDS_TM_CRITERIA_INTERNAL>-SUPERVISOR_RANGE = 1.
ENDLOOP.

LOOP AT IT_EHFNDS_TM_CRITERIA_INTERNAL INTO WA_EHFNDS_TM_CRITERIA_INTERNAL.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_EHFNDS_TM_CRITERIA_INTERNAL-TASK_WO_PROCESSOR, sy-vline,
WA_EHFNDS_TM_CRITERIA_INTERNAL-INCL_PROC_EMPLS, sy-vline,
WA_EHFNDS_TM_CRITERIA_INTERNAL-ONLY_OVERDUE, sy-vline,
WA_EHFNDS_TM_CRITERIA_INTERNAL-TASK_DUEDATE, sy-vline,
WA_EHFNDS_TM_CRITERIA_INTERNAL-ONLY_RECURRENT, sy-vline,
WA_EHFNDS_TM_CRITERIA_INTERNAL-TASK_NODE_ID, sy-vline.
ENDLOOP. *Add any further fields from structure WA_EHFNDS_TM_CRITERIA_INTERNAL you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_EHFNDS_TM_CRITERIA_INTERNAL TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_EHFNDS_TM_CRITERIA_INTERNAL INTO WA_EHFNDS_TM_CRITERIA_INTERNAL. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit PARID, internal->external for field TASK_INITIATED_BY CALL FUNCTION 'CONVERSION_EXIT_PARID_OUTPUT' EXPORTING input = WA_EHFNDS_TM_CRITERIA_INTERNAL-TASK_INITIATED_BY IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHFNDS_TM_CRITERIA_INTERNAL-TASK_INITIATED_BY.
WRITE:/ 'New Value:', ld_input.

*Conversion exit PARID, internal->external for field PROCESSOR CALL FUNCTION 'CONVERSION_EXIT_PARID_OUTPUT' EXPORTING input = WA_EHFNDS_TM_CRITERIA_INTERNAL-PROCESSOR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHFNDS_TM_CRITERIA_INTERNAL-PROCESSOR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit DFVAL, internal->external for field PCBO_STATUS CALL FUNCTION 'CONVERSION_EXIT_DFVAL_OUTPUT' EXPORTING input = WA_EHFNDS_TM_CRITERIA_INTERNAL-PCBO_STATUS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHFNDS_TM_CRITERIA_INTERNAL-PCBO_STATUS.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_EHFNDS_TM_CRITERIA_INTERNAL_STR,
EHSM_COMPONENT TYPE STRING,
TASK_INITIATED_BY TYPE STRING,
PROCESSOR TYPE STRING,
PROCESSOR_RANGE TYPE STRING,
SUPERVISOR_RANGE TYPE STRING,
TASK_WO_PROCESSOR TYPE STRING,
INCL_PROC_EMPLS TYPE STRING,
ONLY_OVERDUE TYPE STRING,
TASK_DUEDATE TYPE STRING,
ONLY_RECURRENT TYPE STRING,
TASK_NODE_ID TYPE STRING,
TASK_STATUS TYPE STRING,
TASK_PRIORITY TYPE STRING,
CR_DATE_OF_TASK TYPE STRING,
MAX_NUMBER_OF_TASKS TYPE STRING,
TASK_SUBJECT TYPE STRING,
PCBO_STATUS TYPE STRING,
BO_NODE TYPE STRING,
PROCESS_COMPL_DATE TYPE STRING,
PROC_CREATION_DATE TYPE STRING,
PROC_DURATION_RANGE TYPE STRING,
SIGN TYPE STRING,
OPTION TYPE STRING,
LOW TYPE STRING,
HIGH TYPE STRING,
PROC_FIN_TIME_RANGE TYPE STRING,
SIGN TYPE STRING,
OPTION TYPE STRING,
LOW TYPE STRING,
HIGH TYPE STRING,
PROC_INIT_BY_RANGE_LIST TYPE STRING,
PROC_STATUS_RANGE_LIST TYPE STRING,
PROCESS_COMB_RANGE_LIST TYPE STRING,
MATERIAL_RANGE_LIST TYPE STRING,
SUBSTANCE_ID_RANGE_LIST TYPE STRING,
CUSTOMER_ID_RANGE_LIST TYPE STRING,
SUPPLIER_ID_RANGE_LIST TYPE STRING,
COMPL_CHECK_RANGE_LIST TYPE STRING,
BO_ROOT_KEY_RANGE_LIST TYPE STRING,
BO_NODE_KEY_RANGE_LIST TYPE STRING,
DTA_ROOT_KEY_RANGE_LIST TYPE STRING,
DTA_NODE_KEY_RANGE_LIST TYPE STRING,
WORKITEM_IDS TYPE STRING,
WF_INSTANCE_ID TYPE STRING,
PCBO_ROOT_KEY TYPE STRING,
IS_EMPTY_RESULT TYPE STRING,
IS_DEADLINE_DIRTY TYPE STRING,
ALSO_CHECK_WF_ARCHIVE TYPE STRING,
WI_CR_DATE_FROM TYPE STRING,
WI_CR_DATE_TO TYPE STRING,
WI_CD_RANGE TYPE STRING,
WI_STATE_RANGE TYPE STRING,
WI_TYPE_RANGE TYPE STRING,
WI_AAGENT_RANGE TYPE STRING,
WI_CRUSER_RANGE TYPE STRING,
PCBO_START_DATE_FROM TYPE STRING,
PCBO_START_DATE_TO TYPE STRING,
PCBO_END_DATE_FROM TYPE STRING,
PCBO_END_DATE_TO TYPE STRING,
TASK_STATUS_RANGE_LIST TYPE STRING,
ALL_WF_INSTANCE_IDS TYPE STRING,
PROC_CR_TIME_FROM TYPE STRING,
PROC_CR_TIME_TO TYPE STRING,
PROC_CP_TIME_FROM TYPE STRING,
PROC_CP_TIME_TO TYPE STRING,
ADD_PCBO_SEL_PARAMS TYPE STRING,END OF T_EKKO_STR. DATA: WA_EHFNDS_TM_CRITERIA_INTERNAL_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_EHFNDS_TM_CRITERIA_INTERNAL_STR-EHSM_COMPONENT sy-vline
WA_EHFNDS_TM_CRITERIA_INTERNAL_STR-TASK_INITIATED_BY sy-vline
WA_EHFNDS_TM_CRITERIA_INTERNAL_STR-PROCESSOR sy-vline
WA_EHFNDS_TM_CRITERIA_INTERNAL_STR-PROCESSOR_RANGE sy-vline
WA_EHFNDS_TM_CRITERIA_INTERNAL_STR-SUPERVISOR_RANGE sy-vline
WA_EHFNDS_TM_CRITERIA_INTERNAL_STR-TASK_WO_PROCESSOR sy-vline
WA_EHFNDS_TM_CRITERIA_INTERNAL_STR-INCL_PROC_EMPLS sy-vline
WA_EHFNDS_TM_CRITERIA_INTERNAL_STR-ONLY_OVERDUE sy-vline
WA_EHFNDS_TM_CRITERIA_INTERNAL_STR-TASK_DUEDATE sy-vline
WA_EHFNDS_TM_CRITERIA_INTERNAL_STR-ONLY_RECURRENT sy-vline
WA_EHFNDS_TM_CRITERIA_INTERNAL_STR-TASK_NODE_ID sy-vline
WA_EHFNDS_TM_CRITERIA_INTERNAL_STR-TASK_STATUS sy-vline
WA_EHFNDS_TM_CRITERIA_INTERNAL_STR-TASK_PRIORITY sy-vline
WA_EHFNDS_TM_CRITERIA_INTERNAL_STR-CR_DATE_OF_TASK sy-vline
WA_EHFNDS_TM_CRITERIA_INTERNAL_STR-MAX_NUMBER_OF_TASKS sy-vline
WA_EHFNDS_TM_CRITERIA_INTERNAL_STR-TASK_SUBJECT sy-vline
WA_EHFNDS_TM_CRITERIA_INTERNAL_STR-PCBO_STATUS sy-vline
WA_EHFNDS_TM_CRITERIA_INTERNAL_STR-BO_NODE sy-vline
WA_EHFNDS_TM_CRITERIA_INTERNAL_STR-PROCESS_COMPL_DATE sy-vline
WA_EHFNDS_TM_CRITERIA_INTERNAL_STR-PROC_CREATION_DATE sy-vline
WA_EHFNDS_TM_CRITERIA_INTERNAL_STR-PROC_DURATION_RANGE sy-vline
WA_EHFNDS_TM_CRITERIA_INTERNAL_STR-SIGN sy-vline
WA_EHFNDS_TM_CRITERIA_INTERNAL_STR-OPTION sy-vline
WA_EHFNDS_TM_CRITERIA_INTERNAL_STR-LOW sy-vline
WA_EHFNDS_TM_CRITERIA_INTERNAL_STR-HIGH sy-vline
WA_EHFNDS_TM_CRITERIA_INTERNAL_STR-PROC_FIN_TIME_RANGE sy-vline
WA_EHFNDS_TM_CRITERIA_INTERNAL_STR-SIGN sy-vline
WA_EHFNDS_TM_CRITERIA_INTERNAL_STR-OPTION sy-vline
WA_EHFNDS_TM_CRITERIA_INTERNAL_STR-LOW sy-vline
WA_EHFNDS_TM_CRITERIA_INTERNAL_STR-HIGH sy-vline
WA_EHFNDS_TM_CRITERIA_INTERNAL_STR-PROC_INIT_BY_RANGE_LIST sy-vline
WA_EHFNDS_TM_CRITERIA_INTERNAL_STR-PROC_STATUS_RANGE_LIST sy-vline
WA_EHFNDS_TM_CRITERIA_INTERNAL_STR-PROCESS_COMB_RANGE_LIST sy-vline
WA_EHFNDS_TM_CRITERIA_INTERNAL_STR-MATERIAL_RANGE_LIST sy-vline
WA_EHFNDS_TM_CRITERIA_INTERNAL_STR-SUBSTANCE_ID_RANGE_LIST sy-vline
WA_EHFNDS_TM_CRITERIA_INTERNAL_STR-CUSTOMER_ID_RANGE_LIST sy-vline
WA_EHFNDS_TM_CRITERIA_INTERNAL_STR-SUPPLIER_ID_RANGE_LIST sy-vline
WA_EHFNDS_TM_CRITERIA_INTERNAL_STR-COMPL_CHECK_RANGE_LIST sy-vline
WA_EHFNDS_TM_CRITERIA_INTERNAL_STR-BO_ROOT_KEY_RANGE_LIST sy-vline
WA_EHFNDS_TM_CRITERIA_INTERNAL_STR-BO_NODE_KEY_RANGE_LIST sy-vline
WA_EHFNDS_TM_CRITERIA_INTERNAL_STR-DTA_ROOT_KEY_RANGE_LIST sy-vline
WA_EHFNDS_TM_CRITERIA_INTERNAL_STR-DTA_NODE_KEY_RANGE_LIST sy-vline
WA_EHFNDS_TM_CRITERIA_INTERNAL_STR-WORKITEM_IDS sy-vline
WA_EHFNDS_TM_CRITERIA_INTERNAL_STR-WF_INSTANCE_ID sy-vline
WA_EHFNDS_TM_CRITERIA_INTERNAL_STR-PCBO_ROOT_KEY sy-vline
WA_EHFNDS_TM_CRITERIA_INTERNAL_STR-IS_EMPTY_RESULT sy-vline
WA_EHFNDS_TM_CRITERIA_INTERNAL_STR-IS_DEADLINE_DIRTY sy-vline
WA_EHFNDS_TM_CRITERIA_INTERNAL_STR-ALSO_CHECK_WF_ARCHIVE sy-vline
WA_EHFNDS_TM_CRITERIA_INTERNAL_STR-WI_CR_DATE_FROM sy-vline
WA_EHFNDS_TM_CRITERIA_INTERNAL_STR-WI_CR_DATE_TO sy-vline
WA_EHFNDS_TM_CRITERIA_INTERNAL_STR-WI_CD_RANGE sy-vline
WA_EHFNDS_TM_CRITERIA_INTERNAL_STR-WI_STATE_RANGE sy-vline
WA_EHFNDS_TM_CRITERIA_INTERNAL_STR-WI_TYPE_RANGE sy-vline
WA_EHFNDS_TM_CRITERIA_INTERNAL_STR-WI_AAGENT_RANGE sy-vline
WA_EHFNDS_TM_CRITERIA_INTERNAL_STR-WI_CRUSER_RANGE sy-vline
WA_EHFNDS_TM_CRITERIA_INTERNAL_STR-PCBO_START_DATE_FROM sy-vline
WA_EHFNDS_TM_CRITERIA_INTERNAL_STR-PCBO_START_DATE_TO sy-vline
WA_EHFNDS_TM_CRITERIA_INTERNAL_STR-PCBO_END_DATE_FROM sy-vline
WA_EHFNDS_TM_CRITERIA_INTERNAL_STR-PCBO_END_DATE_TO sy-vline
WA_EHFNDS_TM_CRITERIA_INTERNAL_STR-TASK_STATUS_RANGE_LIST sy-vline
WA_EHFNDS_TM_CRITERIA_INTERNAL_STR-ALL_WF_INSTANCE_IDS sy-vline
WA_EHFNDS_TM_CRITERIA_INTERNAL_STR-PROC_CR_TIME_FROM sy-vline
WA_EHFNDS_TM_CRITERIA_INTERNAL_STR-PROC_CR_TIME_TO sy-vline
WA_EHFNDS_TM_CRITERIA_INTERNAL_STR-PROC_CP_TIME_FROM sy-vline
WA_EHFNDS_TM_CRITERIA_INTERNAL_STR-PROC_CP_TIME_TO sy-vline
WA_EHFNDS_TM_CRITERIA_INTERNAL_STR-ADD_PCBO_SEL_PARAMS sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.