ABAP Select data from SAP table EHHSSS_INC_BASIC_INFO_ALL_D into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP EHHSSS_INC_BASIC_INFO_ALL_D table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to EHHSSS_INC_BASIC_INFO_ALL_D. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the EHHSSS_INC_BASIC_INFO_ALL_D table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_EHHSSS_INC_BASIC_INFO_ALL_D TYPE STANDARD TABLE OF EHHSSS_INC_BASIC_INFO_ALL_D, WA_EHHSSS_INC_BASIC_INFO_ALL_D TYPE EHHSSS_INC_BASIC_INFO_ALL_D, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <EHHSSS_INC_BASIC_INFO_ALL_D> TYPE EHHSSS_INC_BASIC_INFO_ALL_D. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_EHHSSS_INC_BASIC_INFO_ALL_D. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM EHHSSS_INC_BASIC_INFO_ALL_D INTO TABLE IT_EHHSSS_INC_BASIC_INFO_ALL_D. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM EHHSSS_INC_BASIC_INFO_ALL_D * INTO TABLE @DATA(IT_EHHSSS_INC_BASIC_INFO_ALL_D2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_EHHSSS_INC_BASIC_INFO_ALL_D INDEX 1 INTO DATA(WA_EHHSSS_INC_BASIC_INFO_ALL_D2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_EHHSSS_INC_BASIC_INFO_ALL_D ASSIGNING <EHHSSS_INC_BASIC_INFO_ALL_D>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<EHHSSS_INC_BASIC_INFO_ALL_D>-DATETIME_CR = 1.
<EHHSSS_INC_BASIC_INFO_ALL_D>-USER_ID_CR = 1.
<EHHSSS_INC_BASIC_INFO_ALL_D>-DATETIME_CH = 1.
<EHHSSS_INC_BASIC_INFO_ALL_D>-USER_ID_CH = 1.
<EHHSSS_INC_BASIC_INFO_ALL_D>-TITLE = 1.
ENDLOOP. LOOP AT IT_EHHSSS_INC_BASIC_INFO_ALL_D INTO WA_EHHSSS_INC_BASIC_INFO_ALL_D. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_EHHSSS_INC_BASIC_INFO_ALL_D-ORG_ID, sy-vline,
WA_EHHSSS_INC_BASIC_INFO_ALL_D-PLANT_ID, sy-vline,
WA_EHHSSS_INC_BASIC_INFO_ALL_D-LOC_ROOT_KEY_REF, sy-vline,
WA_EHHSSS_INC_BASIC_INFO_ALL_D-LOC_TYPE, sy-vline,
WA_EHHSSS_INC_BASIC_INFO_ALL_D-START_TIMESTAMP, sy-vline,
WA_EHHSSS_INC_BASIC_INFO_ALL_D-START_TIME_ZONE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_EHHSSS_INC_BASIC_INFO_ALL_D you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_EHHSSS_INC_BASIC_INFO_ALL_D TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_EHHSSS_INC_BASIC_INFO_ALL_D INTO WA_EHHSSS_INC_BASIC_INFO_ALL_D. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit TSTLC, internal->external for field DATETIME_CR CALL FUNCTION 'CONVERSION_EXIT_TSTLC_OUTPUT' EXPORTING input = WA_EHHSSS_INC_BASIC_INFO_ALL_D-DATETIME_CR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHHSSS_INC_BASIC_INFO_ALL_D-DATETIME_CR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit TSTLC, internal->external for field DATETIME_CH CALL FUNCTION 'CONVERSION_EXIT_TSTLC_OUTPUT' EXPORTING input = WA_EHHSSS_INC_BASIC_INFO_ALL_D-DATETIME_CH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHHSSS_INC_BASIC_INFO_ALL_D-DATETIME_CH.
WRITE:/ 'New Value:', ld_input.
*Conversion exit EHPOS, internal->external for field ORG_ID CALL FUNCTION 'CONVERSION_EXIT_EHPOS_OUTPUT' EXPORTING input = WA_EHHSSS_INC_BASIC_INFO_ALL_D-ORG_ID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHHSSS_INC_BASIC_INFO_ALL_D-ORG_ID.
WRITE:/ 'New Value:', ld_input.
*Conversion exit LCRID, internal->external for field LOC_ROOT_KEY_REF CALL FUNCTION 'CONVERSION_EXIT_LCRID_OUTPUT' EXPORTING input = WA_EHHSSS_INC_BASIC_INFO_ALL_D-LOC_ROOT_KEY_REF IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHHSSS_INC_BASIC_INFO_ALL_D-LOC_ROOT_KEY_REF.
WRITE:/ 'New Value:', ld_input.
*Conversion exit EHLTC, internal->external for field LOC_TYPE CALL FUNCTION 'CONVERSION_EXIT_EHLTC_OUTPUT' EXPORTING input = WA_EHHSSS_INC_BASIC_INFO_ALL_D-LOC_TYPE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHHSSS_INC_BASIC_INFO_ALL_D-LOC_TYPE.
WRITE:/ 'New Value:', ld_input.
*Conversion exit TSTLC, internal->external for field START_TIMESTAMP CALL FUNCTION 'CONVERSION_EXIT_TSTLC_OUTPUT' EXPORTING input = WA_EHHSSS_INC_BASIC_INFO_ALL_D-START_TIMESTAMP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHHSSS_INC_BASIC_INFO_ALL_D-START_TIMESTAMP.
WRITE:/ 'New Value:', ld_input.
*Conversion exit TSTLC, internal->external for field END_TIMESTAMP CALL FUNCTION 'CONVERSION_EXIT_TSTLC_OUTPUT' EXPORTING input = WA_EHHSSS_INC_BASIC_INFO_ALL_D-END_TIMESTAMP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHHSSS_INC_BASIC_INFO_ALL_D-END_TIMESTAMP.
WRITE:/ 'New Value:', ld_input.
*Conversion exit TSTLC, internal->external for field REP_TIMESTAMP CALL FUNCTION 'CONVERSION_EXIT_TSTLC_OUTPUT' EXPORTING input = WA_EHHSSS_INC_BASIC_INFO_ALL_D-REP_TIMESTAMP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHHSSS_INC_BASIC_INFO_ALL_D-REP_TIMESTAMP.
WRITE:/ 'New Value:', ld_input.
*Conversion exit EHMIN, internal->external for field LATIT_MEAS CALL FUNCTION 'CONVERSION_EXIT_EHMIN_OUTPUT' EXPORTING input = WA_EHHSSS_INC_BASIC_INFO_ALL_D-LATIT_MEAS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHHSSS_INC_BASIC_INFO_ALL_D-LATIT_MEAS.
WRITE:/ 'New Value:', ld_input.
*Conversion exit EHMIN, internal->external for field LONG_MEAS CALL FUNCTION 'CONVERSION_EXIT_EHMIN_OUTPUT' EXPORTING input = WA_EHHSSS_INC_BASIC_INFO_ALL_D-LONG_MEAS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHHSSS_INC_BASIC_INFO_ALL_D-LONG_MEAS.
WRITE:/ 'New Value:', ld_input.
*Conversion exit EHMIN, internal->external for field ALTIT_MEAS CALL FUNCTION 'CONVERSION_EXIT_EHMIN_OUTPUT' EXPORTING input = WA_EHHSSS_INC_BASIC_INFO_ALL_D-ALTIT_MEAS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHHSSS_INC_BASIC_INFO_ALL_D-ALTIT_MEAS.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field ALTIT_UNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_EHHSSS_INC_BASIC_INFO_ALL_D-ALTIT_UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHHSSS_INC_BASIC_INFO_ALL_D-ALTIT_UNIT.
WRITE:/ 'New Value:', ld_input.
*Conversion exit EHUNI, internal->external for field DIS_WA_UNIT CALL FUNCTION 'CONVERSION_EXIT_EHUNI_OUTPUT' EXPORTING input = WA_EHHSSS_INC_BASIC_INFO_ALL_D-DIS_WA_UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHHSSS_INC_BASIC_INFO_ALL_D-DIS_WA_UNIT.
WRITE:/ 'New Value:', ld_input.
*Conversion exit EHUNI, internal->external for field PRECIP_UNIT CALL FUNCTION 'CONVERSION_EXIT_EHUNI_OUTPUT' EXPORTING input = WA_EHHSSS_INC_BASIC_INFO_ALL_D-PRECIP_UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHHSSS_INC_BASIC_INFO_ALL_D-PRECIP_UNIT.
WRITE:/ 'New Value:', ld_input.
*Conversion exit EHWDC, internal->external for field WI_DIREC CALL FUNCTION 'CONVERSION_EXIT_EHWDC_OUTPUT' EXPORTING input = WA_EHHSSS_INC_BASIC_INFO_ALL_D-WI_DIREC IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHHSSS_INC_BASIC_INFO_ALL_D-WI_DIREC.
WRITE:/ 'New Value:', ld_input.
*Conversion exit EHUNI, internal->external for field WI_FO_UNIT CALL FUNCTION 'CONVERSION_EXIT_EHUNI_OUTPUT' EXPORTING input = WA_EHHSSS_INC_BASIC_INFO_ALL_D-WI_FO_UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHHSSS_INC_BASIC_INFO_ALL_D-WI_FO_UNIT.
WRITE:/ 'New Value:', ld_input.
*Conversion exit EHETC, internal->external for field TYPE CALL FUNCTION 'CONVERSION_EXIT_EHETC_OUTPUT' EXPORTING input = WA_EHHSSS_INC_BASIC_INFO_ALL_D-TYPE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHHSSS_INC_BASIC_INFO_ALL_D-TYPE.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_EHHSSS_INC_BASIC_INFO_ALL_D_STR,
DATETIME_CR TYPE STRING,
USER_ID_CR TYPE STRING,
DATETIME_CH TYPE STRING,
USER_ID_CH TYPE STRING,
TITLE TYPE STRING,
ORG_ID TYPE STRING,
PLANT_ID TYPE STRING,
LOC_ROOT_KEY_REF TYPE STRING,
LOC_TYPE TYPE STRING,
START_TIMESTAMP TYPE STRING,
START_TIME_ZONE TYPE STRING,
END_TIMESTAMP TYPE STRING,
END_TIME_ZONE TYPE STRING,
TIME_NOT_DET_IND TYPE STRING,
REP_TIMESTAMP TYPE STRING,
REP_TIME_ZONE TYPE STRING,
CONFIDENTIAL_TS TYPE STRING,
LOSS_OF_PROD_TS TYPE STRING,
EMERG_RESP_TS TYPE STRING,
LATIT_MEAS TYPE STRING,
LONG_MEAS TYPE STRING,
ALTIT_MEAS TYPE STRING,
ALTIT_UNIT TYPE STRING,
STREET_HOUSE_NUM TYPE STRING,
POSTAL_CODE TYPE STRING,
CITY TYPE STRING,
COUNTRY TYPE STRING,
REGION TYPE STRING,
SHIFT_GROUP TYPE STRING,
SHIFT_PLAN_ID TYPE STRING,
REP_ANONYM_IND TYPE STRING,
DIS_WA_MEAS TYPE STRING,
DIS_WA_UNIT TYPE STRING,
PRECIP_MEAS TYPE STRING,
PRECIP_UNIT TYPE STRING,
WI_DIREC TYPE STRING,
WI_FO_MEAS TYPE STRING,
WI_FO_UNIT TYPE STRING,
TXC_WEA_COMM_KEY TYPE STRING,
TXC_DESC_KEY TYPE STRING,
TXC_LOC_DESC_KEY TYPE STRING,
TXC_IMA_DESC_KEY TYPE STRING,
TYPE TYPE STRING,
EEW_INC_BINFA_D TYPE STRING,END OF T_EKKO_STR. DATA: WA_EHHSSS_INC_BASIC_INFO_ALL_D_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_EHHSSS_INC_BASIC_INFO_ALL_D_STR-DATETIME_CR sy-vline
WA_EHHSSS_INC_BASIC_INFO_ALL_D_STR-USER_ID_CR sy-vline
WA_EHHSSS_INC_BASIC_INFO_ALL_D_STR-DATETIME_CH sy-vline
WA_EHHSSS_INC_BASIC_INFO_ALL_D_STR-USER_ID_CH sy-vline
WA_EHHSSS_INC_BASIC_INFO_ALL_D_STR-TITLE sy-vline
WA_EHHSSS_INC_BASIC_INFO_ALL_D_STR-ORG_ID sy-vline
WA_EHHSSS_INC_BASIC_INFO_ALL_D_STR-PLANT_ID sy-vline
WA_EHHSSS_INC_BASIC_INFO_ALL_D_STR-LOC_ROOT_KEY_REF sy-vline
WA_EHHSSS_INC_BASIC_INFO_ALL_D_STR-LOC_TYPE sy-vline
WA_EHHSSS_INC_BASIC_INFO_ALL_D_STR-START_TIMESTAMP sy-vline
WA_EHHSSS_INC_BASIC_INFO_ALL_D_STR-START_TIME_ZONE sy-vline
WA_EHHSSS_INC_BASIC_INFO_ALL_D_STR-END_TIMESTAMP sy-vline
WA_EHHSSS_INC_BASIC_INFO_ALL_D_STR-END_TIME_ZONE sy-vline
WA_EHHSSS_INC_BASIC_INFO_ALL_D_STR-TIME_NOT_DET_IND sy-vline
WA_EHHSSS_INC_BASIC_INFO_ALL_D_STR-REP_TIMESTAMP sy-vline
WA_EHHSSS_INC_BASIC_INFO_ALL_D_STR-REP_TIME_ZONE sy-vline
WA_EHHSSS_INC_BASIC_INFO_ALL_D_STR-CONFIDENTIAL_TS sy-vline
WA_EHHSSS_INC_BASIC_INFO_ALL_D_STR-LOSS_OF_PROD_TS sy-vline
WA_EHHSSS_INC_BASIC_INFO_ALL_D_STR-EMERG_RESP_TS sy-vline
WA_EHHSSS_INC_BASIC_INFO_ALL_D_STR-LATIT_MEAS sy-vline
WA_EHHSSS_INC_BASIC_INFO_ALL_D_STR-LONG_MEAS sy-vline
WA_EHHSSS_INC_BASIC_INFO_ALL_D_STR-ALTIT_MEAS sy-vline
WA_EHHSSS_INC_BASIC_INFO_ALL_D_STR-ALTIT_UNIT sy-vline
WA_EHHSSS_INC_BASIC_INFO_ALL_D_STR-STREET_HOUSE_NUM sy-vline
WA_EHHSSS_INC_BASIC_INFO_ALL_D_STR-POSTAL_CODE sy-vline
WA_EHHSSS_INC_BASIC_INFO_ALL_D_STR-CITY sy-vline
WA_EHHSSS_INC_BASIC_INFO_ALL_D_STR-COUNTRY sy-vline
WA_EHHSSS_INC_BASIC_INFO_ALL_D_STR-REGION sy-vline
WA_EHHSSS_INC_BASIC_INFO_ALL_D_STR-SHIFT_GROUP sy-vline
WA_EHHSSS_INC_BASIC_INFO_ALL_D_STR-SHIFT_PLAN_ID sy-vline
WA_EHHSSS_INC_BASIC_INFO_ALL_D_STR-REP_ANONYM_IND sy-vline
WA_EHHSSS_INC_BASIC_INFO_ALL_D_STR-DIS_WA_MEAS sy-vline
WA_EHHSSS_INC_BASIC_INFO_ALL_D_STR-DIS_WA_UNIT sy-vline
WA_EHHSSS_INC_BASIC_INFO_ALL_D_STR-PRECIP_MEAS sy-vline
WA_EHHSSS_INC_BASIC_INFO_ALL_D_STR-PRECIP_UNIT sy-vline
WA_EHHSSS_INC_BASIC_INFO_ALL_D_STR-WI_DIREC sy-vline
WA_EHHSSS_INC_BASIC_INFO_ALL_D_STR-WI_FO_MEAS sy-vline
WA_EHHSSS_INC_BASIC_INFO_ALL_D_STR-WI_FO_UNIT sy-vline
WA_EHHSSS_INC_BASIC_INFO_ALL_D_STR-TXC_WEA_COMM_KEY sy-vline
WA_EHHSSS_INC_BASIC_INFO_ALL_D_STR-TXC_DESC_KEY sy-vline
WA_EHHSSS_INC_BASIC_INFO_ALL_D_STR-TXC_LOC_DESC_KEY sy-vline
WA_EHHSSS_INC_BASIC_INFO_ALL_D_STR-TXC_IMA_DESC_KEY sy-vline
WA_EHHSSS_INC_BASIC_INFO_ALL_D_STR-TYPE sy-vline
WA_EHHSSS_INC_BASIC_INFO_ALL_D_STR-EEW_INC_BINFA_D sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.