ABAP Select data from SAP table EHPMAS_SVT_SUB_CLC_DISPL_INF into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP EHPMAS_SVT_SUB_CLC_DISPL_INF table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to EHPMAS_SVT_SUB_CLC_DISPL_INF. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the EHPMAS_SVT_SUB_CLC_DISPL_INF table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_EHPMAS_SVT_SUB_CLC_DISPL_INF TYPE STANDARD TABLE OF EHPMAS_SVT_SUB_CLC_DISPL_INF, WA_EHPMAS_SVT_SUB_CLC_DISPL_INF TYPE EHPMAS_SVT_SUB_CLC_DISPL_INF, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <EHPMAS_SVT_SUB_CLC_DISPL_INF> TYPE EHPMAS_SVT_SUB_CLC_DISPL_INF. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_EHPMAS_SVT_SUB_CLC_DISPL_INF. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM EHPMAS_SVT_SUB_CLC_DISPL_INF INTO TABLE IT_EHPMAS_SVT_SUB_CLC_DISPL_INF. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM EHPMAS_SVT_SUB_CLC_DISPL_INF * INTO TABLE @DATA(IT_EHPMAS_SVT_SUB_CLC_DISPL_INF2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_EHPMAS_SVT_SUB_CLC_DISPL_INF INDEX 1 INTO DATA(WA_EHPMAS_SVT_SUB_CLC_DISPL_INF2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_EHPMAS_SVT_SUB_CLC_DISPL_INF ASSIGNING <EHPMAS_SVT_SUB_CLC_DISPL_INF>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<EHPMAS_SVT_SUB_CLC_DISPL_INF>-UPROFILE_UUID = 1.
<EHPMAS_SVT_SUB_CLC_DISPL_INF>-SUB = 1.
<EHPMAS_SVT_SUB_CLC_DISPL_INF>-CRV = 1.
<EHPMAS_SVT_SUB_CLC_DISPL_INF>-SUBSTANCEROLEOFINGREDIENT = 1.
<EHPMAS_SVT_SUB_CLC_DISPL_INF>-CRR_CHANGE_DATE = 1.
ENDLOOP. LOOP AT IT_EHPMAS_SVT_SUB_CLC_DISPL_INF INTO WA_EHPMAS_SVT_SUB_CLC_DISPL_INF. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_EHPMAS_SVT_SUB_CLC_DISPL_INF-SUB_CHANGE_DATE, sy-vline,
WA_EHPMAS_SVT_SUB_CLC_DISPL_INF-CRV_SUB_LIST, sy-vline,
WA_EHPMAS_SVT_SUB_CLC_DISPL_INF-VALIDITY_START_DATE, sy-vline,
WA_EHPMAS_SVT_SUB_CLC_DISPL_INF-VALIDITY_END_DATE, sy-vline,
WA_EHPMAS_SVT_SUB_CLC_DISPL_INF-EVENT_TYPE, sy-vline,
WA_EHPMAS_SVT_SUB_CLC_DISPL_INF-CRV_EFFECTIVE_DATE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_EHPMAS_SVT_SUB_CLC_DISPL_INF you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_EHPMAS_SVT_SUB_CLC_DISPL_INF TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_EHPMAS_SVT_SUB_CLC_DISPL_INF INTO WA_EHPMAS_SVT_SUB_CLC_DISPL_INF. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit CMPTP, internal->external for field SUBSTANCEROLEOFINGREDIENT CALL FUNCTION 'CONVERSION_EXIT_CMPTP_OUTPUT' EXPORTING input = WA_EHPMAS_SVT_SUB_CLC_DISPL_INF-SUBSTANCEROLEOFINGREDIENT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHPMAS_SVT_SUB_CLC_DISPL_INF-SUBSTANCEROLEOFINGREDIENT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_EHPMAS_SVT_SUB_CLC_DISPL_INF_STR,
UPROFILE_UUID TYPE STRING,
SUB TYPE STRING,
CRV TYPE STRING,
SUBSTANCEROLEOFINGREDIENT TYPE STRING,
CRR_CHANGE_DATE TYPE STRING,
SUB_CHANGE_DATE TYPE STRING,
CRV_SUB_LIST TYPE STRING,
VALIDITY_START_DATE TYPE STRING,
VALIDITY_END_DATE TYPE STRING,
EVENT_TYPE TYPE STRING,
CRV_EFFECTIVE_DATE TYPE STRING,END OF T_EKKO_STR. DATA: WA_EHPMAS_SVT_SUB_CLC_DISPL_INF_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_EHPMAS_SVT_SUB_CLC_DISPL_INF_STR-UPROFILE_UUID sy-vline
WA_EHPMAS_SVT_SUB_CLC_DISPL_INF_STR-SUB sy-vline
WA_EHPMAS_SVT_SUB_CLC_DISPL_INF_STR-CRV sy-vline
WA_EHPMAS_SVT_SUB_CLC_DISPL_INF_STR-SUBSTANCEROLEOFINGREDIENT sy-vline
WA_EHPMAS_SVT_SUB_CLC_DISPL_INF_STR-CRR_CHANGE_DATE sy-vline
WA_EHPMAS_SVT_SUB_CLC_DISPL_INF_STR-SUB_CHANGE_DATE sy-vline
WA_EHPMAS_SVT_SUB_CLC_DISPL_INF_STR-CRV_SUB_LIST sy-vline
WA_EHPMAS_SVT_SUB_CLC_DISPL_INF_STR-VALIDITY_START_DATE sy-vline
WA_EHPMAS_SVT_SUB_CLC_DISPL_INF_STR-VALIDITY_END_DATE sy-vline
WA_EHPMAS_SVT_SUB_CLC_DISPL_INF_STR-EVENT_TYPE sy-vline
WA_EHPMAS_SVT_SUB_CLC_DISPL_INF_STR-CRV_EFFECTIVE_DATE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.