ABAP Select data from SAP table EMG_INSTPLAN into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP EMG_INSTPLAN table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to EMG_INSTPLAN. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the EMG_INSTPLAN table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_EMG_INSTPLAN TYPE STANDARD TABLE OF EMG_INSTPLAN, WA_EMG_INSTPLAN TYPE EMG_INSTPLAN, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <EMG_INSTPLAN> TYPE EMG_INSTPLAN. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_EMG_INSTPLAN. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM EMG_INSTPLAN INTO TABLE IT_EMG_INSTPLAN. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM EMG_INSTPLAN * INTO TABLE @DATA(IT_EMG_INSTPLAN2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_EMG_INSTPLAN INDEX 1 INTO DATA(WA_EMG_INSTPLAN2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_EMG_INSTPLAN ASSIGNING <EMG_INSTPLAN>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<EMG_INSTPLAN>-WAERS = 1.
<EMG_INSTPLAN>-BUDAT = 1.
<EMG_INSTPLAN>-BLDAT = 1.
<EMG_INSTPLAN>-GPART = 1.
<EMG_INSTPLAN>-VKONT = 1.
ENDLOOP. LOOP AT IT_EMG_INSTPLAN INTO WA_EMG_INSTPLAN. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_EMG_INSTPLAN-BLART, sy-vline,
WA_EMG_INSTPLAN-OPBEL, sy-vline,
WA_EMG_INSTPLAN-BUKRS, sy-vline,
WA_EMG_INSTPLAN-RPCAT, sy-vline,
WA_EMG_INSTPLAN-RPRDA, sy-vline,
WA_EMG_INSTPLAN-DRCDT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_EMG_INSTPLAN you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_EMG_INSTPLAN TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_EMG_INSTPLAN INTO WA_EMG_INSTPLAN. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ALPHA, internal->external for field GPART CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EMG_INSTPLAN-GPART IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EMG_INSTPLAN-GPART.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field VKONT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EMG_INSTPLAN-VKONT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EMG_INSTPLAN-VKONT.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field OPBEL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EMG_INSTPLAN-OPBEL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EMG_INSTPLAN-OPBEL.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_EMG_INSTPLAN_STR,
WAERS TYPE STRING,
BUDAT TYPE STRING,
BLDAT TYPE STRING,
GPART TYPE STRING,
VKONT TYPE STRING,
BLART TYPE STRING,
OPBEL TYPE STRING,
BUKRS TYPE STRING,
RPCAT TYPE STRING,
RPRDA TYPE STRING,
DRCDT TYPE STRING,
TVORG TYPE STRING,END OF T_EKKO_STR. DATA: WA_EMG_INSTPLAN_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_EMG_INSTPLAN_STR-WAERS sy-vline
WA_EMG_INSTPLAN_STR-BUDAT sy-vline
WA_EMG_INSTPLAN_STR-BLDAT sy-vline
WA_EMG_INSTPLAN_STR-GPART sy-vline
WA_EMG_INSTPLAN_STR-VKONT sy-vline
WA_EMG_INSTPLAN_STR-BLART sy-vline
WA_EMG_INSTPLAN_STR-OPBEL sy-vline
WA_EMG_INSTPLAN_STR-BUKRS sy-vline
WA_EMG_INSTPLAN_STR-RPCAT sy-vline
WA_EMG_INSTPLAN_STR-RPRDA sy-vline
WA_EMG_INSTPLAN_STR-DRCDT sy-vline
WA_EMG_INSTPLAN_STR-TVORG sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.