ABAP Select data from SAP table ENT5647 into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP ENT5647 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to ENT5647. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the ENT5647 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_ENT5647 TYPE STANDARD TABLE OF ENT5647, WA_ENT5647 TYPE ENT5647, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <ENT5647> TYPE ENT5647. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_ENT5647. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM ENT5647 INTO TABLE IT_ENT5647. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM ENT5647 * INTO TABLE @DATA(IT_ENT56472). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_ENT5647 INDEX 1 INTO DATA(WA_ENT56472). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_ENT5647 ASSIGNING <ENT5647>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<ENT5647>-MANDT = 1.
<ENT5647>-PLNTY = 1.
<ENT5647>-PLNNR = 1.
<ENT5647>-PLNAL = 1.
<ENT5647>-PLNFL = 1.
ENDLOOP. LOOP AT IT_ENT5647 INTO WA_ENT5647. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_ENT5647-PLNKN, sy-vline,
WA_ENT5647-PAKET, sy-vline,
WA_ENT5647-ZAEHL, sy-vline,
WA_ENT5647-DATUV, sy-vline,
WA_ENT5647-TECHV, sy-vline,
WA_ENT5647-STRAT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_ENT5647 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_ENT5647 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_ENT5647 INTO WA_ENT5647. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ALPHA, internal->external for field PLNNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ENT5647-PLNNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ENT5647-PLNNR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field PLNAL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ENT5647-PLNAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ENT5647-PLNAL.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field PLNFL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ENT5647-PLNFL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ENT5647-PLNFL.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field AENNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ENT5647-AENNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ENT5647-AENNR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_ENT5647_STR,
MANDT TYPE STRING,
PLNTY TYPE STRING,
PLNNR TYPE STRING,
PLNAL TYPE STRING,
PLNFL TYPE STRING,
PLNKN TYPE STRING,
PAKET TYPE STRING,
ZAEHL TYPE STRING,
DATUV TYPE STRING,
TECHV TYPE STRING,
STRAT TYPE STRING,
IWPOK TYPE STRING,
FLGWP TYPE STRING,
LOEKZ TYPE STRING,
PARKZ TYPE STRING,
AENNR TYPE STRING,
ANDAT TYPE STRING,
ANNAM TYPE STRING,
AEDAT TYPE STRING,
AENAM TYPE STRING,END OF T_EKKO_STR. DATA: WA_ENT5647_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_ENT5647_STR-MANDT sy-vline
WA_ENT5647_STR-PLNTY sy-vline
WA_ENT5647_STR-PLNNR sy-vline
WA_ENT5647_STR-PLNAL sy-vline
WA_ENT5647_STR-PLNFL sy-vline
WA_ENT5647_STR-PLNKN sy-vline
WA_ENT5647_STR-PAKET sy-vline
WA_ENT5647_STR-ZAEHL sy-vline
WA_ENT5647_STR-DATUV sy-vline
WA_ENT5647_STR-TECHV sy-vline
WA_ENT5647_STR-STRAT sy-vline
WA_ENT5647_STR-IWPOK sy-vline
WA_ENT5647_STR-FLGWP sy-vline
WA_ENT5647_STR-LOEKZ sy-vline
WA_ENT5647_STR-PARKZ sy-vline
WA_ENT5647_STR-AENNR sy-vline
WA_ENT5647_STR-ANDAT sy-vline
WA_ENT5647_STR-ANNAM sy-vline
WA_ENT5647_STR-AEDAT sy-vline
WA_ENT5647_STR-AENAM sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.