ABAP Select data from SAP table ENT5711 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP ENT5711 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to ENT5711. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the ENT5711 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_ENT5711 TYPE STANDARD TABLE OF ENT5711,
      WA_ENT5711 TYPE ENT5711,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <ENT5711> TYPE ENT5711.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_ENT5711.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM ENT5711
  INTO TABLE IT_ENT5711.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM ENT5711
*  INTO TABLE @DATA(IT_ENT57112).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_ENT5711 INDEX 1 INTO DATA(WA_ENT57112).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_ENT5711 ASSIGNING <ENT5711>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<ENT5711>-MANDANT = 1.
<ENT5711>-PRUEFLOS = 1.
<ENT5711>-VORGLFNR = 1.
<ENT5711>-MERKNR = 1.
<ENT5711>-ERSTELLER = 1.
ENDLOOP.

LOOP AT IT_ENT5711 INTO WA_ENT5711.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_ENT5711-ERSTELLDAT, sy-vline,
WA_ENT5711-AENDERER, sy-vline,
WA_ENT5711-AENDERDAT, sy-vline,
WA_ENT5711-PHYSPROBE, sy-vline,
WA_ENT5711-SATZSTATUS, sy-vline,
WA_ENT5711-STEUERKZ, sy-vline.
ENDLOOP. *Add any further fields from structure WA_ENT5711 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_ENT5711 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_ENT5711 INTO WA_ENT5711. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field PRUEFLOS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ENT5711-PRUEFLOS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ENT5711-PRUEFLOS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PMETHODE CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ENT5711-PMETHODE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ENT5711-PMETHODE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PMTVERSION CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ENT5711-PMTVERSION IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ENT5711-PMTVERSION.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field VERWMERKM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ENT5711-VERWMERKM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ENT5711-VERWMERKM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field MKVERSION CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ENT5711-MKVERSION IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ENT5711-MKVERSION.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ISOLA, internal->external for field LTEXTSPR CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_ENT5711-LTEXTSPR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ENT5711-LTEXTSPR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ISOLA, internal->external for field LTXTENTSPR CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_ENT5711-LTXTENTSPR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ENT5711-LTXTENTSPR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field CODEVR9U CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ENT5711-CODEVR9U IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ENT5711-CODEVR9U.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field CODEVR9O CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ENT5711-CODEVR9O IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ENT5711-CODEVR9O.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MASSEINHSW CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_ENT5711-MASSEINHSW IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ENT5711-MASSEINHSW.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field PROBEMGEH CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_ENT5711-PROBEMGEH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ENT5711-PROBEMGEH.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MENGENEINH CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_ENT5711-MENGENEINH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ENT5711-MENGENEINH.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_ENT5711_STR,
MANDANT TYPE STRING,
PRUEFLOS TYPE STRING,
VORGLFNR TYPE STRING,
MERKNR TYPE STRING,
ERSTELLER TYPE STRING,
ERSTELLDAT TYPE STRING,
AENDERER TYPE STRING,
AENDERDAT TYPE STRING,
PHYSPROBE TYPE STRING,
SATZSTATUS TYPE STRING,
STEUERKZ TYPE STRING,
TSTICHPRKZ TYPE STRING,
NOINPUTKZ TYPE STRING,
NIPLANMKKZ TYPE STRING,
QMTB_WERKS TYPE STRING,
PMETHODE TYPE STRING,
PMTVERSION TYPE STRING,
QPMK_WERKS TYPE STRING,
VERWMERKM TYPE STRING,
MKVERSION TYPE STRING,
MERKGEW TYPE STRING,
KURZTEXT TYPE STRING,
LTEXTKZ TYPE STRING,
LTEXTSPR TYPE STRING,
LTEXTEKZ TYPE STRING,
LTXTENTSPR TYPE STRING,
PRUEFQUALI TYPE STRING,
FORMEL1 TYPE STRING,
FORMEL2 TYPE STRING,
DUMMY10 TYPE STRING,
DUMMY20 TYPE STRING,
DUMMY40 TYPE STRING,
CODEGR9U TYPE STRING,
CODE9U TYPE STRING,
CODEGR9O TYPE STRING,
CODEVR9U TYPE STRING,
CODE9O TYPE STRING,
CODEVR9O TYPE STRING,
STELLEN TYPE STRING,
MASSEINHSW TYPE STRING,
SOLLWERT TYPE STRING,
SOLLWNI TYPE STRING,
TOLERANZOB TYPE STRING,
TOLOBNI TYPE STRING,
TOLERANZUN TYPE STRING,
TOLUNNI TYPE STRING,
GRENZEOB1 TYPE STRING,
GRENZOB1NI TYPE STRING,
TOLERWKZ TYPE STRING,
GRENZEUN1 TYPE STRING,
GRENZUN1NI TYPE STRING,
GRENZEOB2 TYPE STRING,
GRENZOB2NI TYPE STRING,
GRENZUN2NI TYPE STRING,
PLAUSIOBEN TYPE STRING,
GRENZEUN2 TYPE STRING,
PLAUSIOBNI TYPE STRING,
PLAUSIUNTE TYPE STRING,
PLAUSIUNNI TYPE STRING,
KLASANZAHL TYPE STRING,
KLASBREITE TYPE STRING,
KLASBRNI TYPE STRING,
KLASMITTE TYPE STRING,
KLASMINI TYPE STRING,
STICHPRVER TYPE STRING,
FAKPLANME TYPE STRING,
FAKPROBME TYPE STRING,
ANTVERF TYPE STRING,
BEWREGEL TYPE STRING,
PROBMGFAK TYPE STRING,
PROBEMGEH TYPE STRING,
SOLLSTPUMF TYPE STRING,
PRUEFUMF TYPE STRING,
MENGENEINH TYPE STRING,
HPZ TYPE STRING,
SOLLSTPANZ TYPE STRING,
ANTEILKZ TYPE STRING,
RUECKMELNR TYPE STRING,
KZEINSTELL TYPE STRING,
ZAEHL TYPE STRING,END OF T_EKKO_STR. DATA: WA_ENT5711_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_ENT5711_STR-MANDANT sy-vline
WA_ENT5711_STR-PRUEFLOS sy-vline
WA_ENT5711_STR-VORGLFNR sy-vline
WA_ENT5711_STR-MERKNR sy-vline
WA_ENT5711_STR-ERSTELLER sy-vline
WA_ENT5711_STR-ERSTELLDAT sy-vline
WA_ENT5711_STR-AENDERER sy-vline
WA_ENT5711_STR-AENDERDAT sy-vline
WA_ENT5711_STR-PHYSPROBE sy-vline
WA_ENT5711_STR-SATZSTATUS sy-vline
WA_ENT5711_STR-STEUERKZ sy-vline
WA_ENT5711_STR-TSTICHPRKZ sy-vline
WA_ENT5711_STR-NOINPUTKZ sy-vline
WA_ENT5711_STR-NIPLANMKKZ sy-vline
WA_ENT5711_STR-QMTB_WERKS sy-vline
WA_ENT5711_STR-PMETHODE sy-vline
WA_ENT5711_STR-PMTVERSION sy-vline
WA_ENT5711_STR-QPMK_WERKS sy-vline
WA_ENT5711_STR-VERWMERKM sy-vline
WA_ENT5711_STR-MKVERSION sy-vline
WA_ENT5711_STR-MERKGEW sy-vline
WA_ENT5711_STR-KURZTEXT sy-vline
WA_ENT5711_STR-LTEXTKZ sy-vline
WA_ENT5711_STR-LTEXTSPR sy-vline
WA_ENT5711_STR-LTEXTEKZ sy-vline
WA_ENT5711_STR-LTXTENTSPR sy-vline
WA_ENT5711_STR-PRUEFQUALI sy-vline
WA_ENT5711_STR-FORMEL1 sy-vline
WA_ENT5711_STR-FORMEL2 sy-vline
WA_ENT5711_STR-DUMMY10 sy-vline
WA_ENT5711_STR-DUMMY20 sy-vline
WA_ENT5711_STR-DUMMY40 sy-vline
WA_ENT5711_STR-CODEGR9U sy-vline
WA_ENT5711_STR-CODE9U sy-vline
WA_ENT5711_STR-CODEGR9O sy-vline
WA_ENT5711_STR-CODEVR9U sy-vline
WA_ENT5711_STR-CODE9O sy-vline
WA_ENT5711_STR-CODEVR9O sy-vline
WA_ENT5711_STR-STELLEN sy-vline
WA_ENT5711_STR-MASSEINHSW sy-vline
WA_ENT5711_STR-SOLLWERT sy-vline
WA_ENT5711_STR-SOLLWNI sy-vline
WA_ENT5711_STR-TOLERANZOB sy-vline
WA_ENT5711_STR-TOLOBNI sy-vline
WA_ENT5711_STR-TOLERANZUN sy-vline
WA_ENT5711_STR-TOLUNNI sy-vline
WA_ENT5711_STR-GRENZEOB1 sy-vline
WA_ENT5711_STR-GRENZOB1NI sy-vline
WA_ENT5711_STR-TOLERWKZ sy-vline
WA_ENT5711_STR-GRENZEUN1 sy-vline
WA_ENT5711_STR-GRENZUN1NI sy-vline
WA_ENT5711_STR-GRENZEOB2 sy-vline
WA_ENT5711_STR-GRENZOB2NI sy-vline
WA_ENT5711_STR-GRENZUN2NI sy-vline
WA_ENT5711_STR-PLAUSIOBEN sy-vline
WA_ENT5711_STR-GRENZEUN2 sy-vline
WA_ENT5711_STR-PLAUSIOBNI sy-vline
WA_ENT5711_STR-PLAUSIUNTE sy-vline
WA_ENT5711_STR-PLAUSIUNNI sy-vline
WA_ENT5711_STR-KLASANZAHL sy-vline
WA_ENT5711_STR-KLASBREITE sy-vline
WA_ENT5711_STR-KLASBRNI sy-vline
WA_ENT5711_STR-KLASMITTE sy-vline
WA_ENT5711_STR-KLASMINI sy-vline
WA_ENT5711_STR-STICHPRVER sy-vline
WA_ENT5711_STR-FAKPLANME sy-vline
WA_ENT5711_STR-FAKPROBME sy-vline
WA_ENT5711_STR-ANTVERF sy-vline
WA_ENT5711_STR-BEWREGEL sy-vline
WA_ENT5711_STR-PROBMGFAK sy-vline
WA_ENT5711_STR-PROBEMGEH sy-vline
WA_ENT5711_STR-SOLLSTPUMF sy-vline
WA_ENT5711_STR-PRUEFUMF sy-vline
WA_ENT5711_STR-MENGENEINH sy-vline
WA_ENT5711_STR-HPZ sy-vline
WA_ENT5711_STR-SOLLSTPANZ sy-vline
WA_ENT5711_STR-ANTEILKZ sy-vline
WA_ENT5711_STR-RUECKMELNR sy-vline
WA_ENT5711_STR-KZEINSTELL sy-vline
WA_ENT5711_STR-ZAEHL sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.