ABAP Select data from SAP table ENT5824 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP ENT5824 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to ENT5824. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the ENT5824 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_ENT5824 TYPE STANDARD TABLE OF ENT5824,
      WA_ENT5824 TYPE ENT5824,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <ENT5824> TYPE ENT5824.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_ENT5824.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM ENT5824
  INTO TABLE IT_ENT5824.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM ENT5824
*  INTO TABLE @DATA(IT_ENT58242).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_ENT5824 INDEX 1 INTO DATA(WA_ENT58242).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_ENT5824 ASSIGNING <ENT5824>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<ENT5824>-MANDT = 1.
<ENT5824>-RUECK = 1.
<ENT5824>-RMZHL = 1.
<ENT5824>-ERSDA = 1.
<ENT5824>-ERNAM = 1.
ENDLOOP.

LOOP AT IT_ENT5824 INTO WA_ENT5824.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_ENT5824-LAEDA, sy-vline,
WA_ENT5824-BUDAT, sy-vline,
WA_ENT5824-AENAM, sy-vline,
WA_ENT5824-AUERU, sy-vline,
WA_ENT5824-AUFPL, sy-vline,
WA_ENT5824-APLZL, sy-vline.
ENDLOOP. *Add any further fields from structure WA_ENT5824 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_ENT5824 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_ENT5824 INTO WA_ENT5824. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field APLFL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ENT5824-APLFL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ENT5824-APLFL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit NUMCV, internal->external for field VORNR CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_ENT5824-VORNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ENT5824-VORNR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_ENT5824_STR,
MANDT TYPE STRING,
RUECK TYPE STRING,
RMZHL TYPE STRING,
ERSDA TYPE STRING,
ERNAM TYPE STRING,
LAEDA TYPE STRING,
BUDAT TYPE STRING,
AENAM TYPE STRING,
AUERU TYPE STRING,
AUFPL TYPE STRING,
APLZL TYPE STRING,
APLFL TYPE STRING,
VORNR TYPE STRING,END OF T_EKKO_STR. DATA: WA_ENT5824_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_ENT5824_STR-MANDT sy-vline
WA_ENT5824_STR-RUECK sy-vline
WA_ENT5824_STR-RMZHL sy-vline
WA_ENT5824_STR-ERSDA sy-vline
WA_ENT5824_STR-ERNAM sy-vline
WA_ENT5824_STR-LAEDA sy-vline
WA_ENT5824_STR-BUDAT sy-vline
WA_ENT5824_STR-AENAM sy-vline
WA_ENT5824_STR-AUERU sy-vline
WA_ENT5824_STR-AUFPL sy-vline
WA_ENT5824_STR-APLZL sy-vline
WA_ENT5824_STR-APLFL sy-vline
WA_ENT5824_STR-VORNR sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.