ABAP Select data from SAP table EPROFILE_INTF into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP EPROFILE_INTF table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to EPROFILE_INTF. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the EPROFILE_INTF table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_EPROFILE_INTF TYPE STANDARD TABLE OF EPROFILE_INTF,
      WA_EPROFILE_INTF TYPE EPROFILE_INTF,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <EPROFILE_INTF> TYPE EPROFILE_INTF.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_EPROFILE_INTF.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM EPROFILE_INTF
  INTO TABLE IT_EPROFILE_INTF.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM EPROFILE_INTF
*  INTO TABLE @DATA(IT_EPROFILE_INTF2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_EPROFILE_INTF INDEX 1 INTO DATA(WA_EPROFILE_INTF2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_EPROFILE_INTF ASSIGNING <EPROFILE_INTF>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<EPROFILE_INTF>-HEAD = 1.
<EPROFILE_INTF>-PROFILE = 1.
<EPROFILE_INTF>-PROF_FROM = 1.
<EPROFILE_INTF>-DATEFROM = 1.
<EPROFILE_INTF>-TIMEFROM = 1.
ENDLOOP.

LOOP AT IT_EPROFILE_INTF INTO WA_EPROFILE_INTF.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_EPROFILE_INTF-FROM_OFFSET, sy-vline,
WA_EPROFILE_INTF-PROF_FROM_LOC, sy-vline,
WA_EPROFILE_INTF-DATEFROM, sy-vline,
WA_EPROFILE_INTF-TIMEFROM, sy-vline,
WA_EPROFILE_INTF-PROF_TO, sy-vline,
WA_EPROFILE_INTF-DATETO, sy-vline.
ENDLOOP. *Add any further fields from structure WA_EPROFILE_INTF you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_EPROFILE_INTF TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_EPROFILE_INTF INTO WA_EPROFILE_INTF. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_EPROFILE_INTF_STR,
HEAD TYPE STRING,
PROFILE TYPE STRING,
PROF_FROM TYPE STRING,
DATEFROM TYPE STRING,
TIMEFROM TYPE STRING,
FROM_OFFSET TYPE STRING,
PROF_FROM_LOC TYPE STRING,
DATEFROM TYPE STRING,
TIMEFROM TYPE STRING,
PROF_TO TYPE STRING,
DATETO TYPE STRING,
TIMETO TYPE STRING,
TO_OFFSET TYPE STRING,
PROF_TO_LOC TYPE STRING,
DATETO TYPE STRING,
TIMETO TYPE STRING,
DOCNUM TYPE STRING,
PROF_TIMEZONE TYPE STRING,
INT_UI TYPE STRING,
EXT_UI TYPE STRING,
LOGIKZW TYPE STRING,
KENNZIFF TYPE STRING,
ROLETYPE TYPE STRING,
PROFROLE TYPE STRING,
SRCSYSTEM TYPE STRING,
SRCADDR TYPE STRING,
EXTREFERENCE TYPE STRING,
EXTLOGNUMBER TYPE STRING,
PROFVAL TYPE STRING,
PROFSTAT TYPE STRING,END OF T_EKKO_STR. DATA: WA_EPROFILE_INTF_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_EPROFILE_INTF_STR-HEAD sy-vline
WA_EPROFILE_INTF_STR-PROFILE sy-vline
WA_EPROFILE_INTF_STR-PROF_FROM sy-vline
WA_EPROFILE_INTF_STR-DATEFROM sy-vline
WA_EPROFILE_INTF_STR-TIMEFROM sy-vline
WA_EPROFILE_INTF_STR-FROM_OFFSET sy-vline
WA_EPROFILE_INTF_STR-PROF_FROM_LOC sy-vline
WA_EPROFILE_INTF_STR-DATEFROM sy-vline
WA_EPROFILE_INTF_STR-TIMEFROM sy-vline
WA_EPROFILE_INTF_STR-PROF_TO sy-vline
WA_EPROFILE_INTF_STR-DATETO sy-vline
WA_EPROFILE_INTF_STR-TIMETO sy-vline
WA_EPROFILE_INTF_STR-TO_OFFSET sy-vline
WA_EPROFILE_INTF_STR-PROF_TO_LOC sy-vline
WA_EPROFILE_INTF_STR-DATETO sy-vline
WA_EPROFILE_INTF_STR-TIMETO sy-vline
WA_EPROFILE_INTF_STR-DOCNUM sy-vline
WA_EPROFILE_INTF_STR-PROF_TIMEZONE sy-vline
WA_EPROFILE_INTF_STR-INT_UI sy-vline
WA_EPROFILE_INTF_STR-EXT_UI sy-vline
WA_EPROFILE_INTF_STR-LOGIKZW sy-vline
WA_EPROFILE_INTF_STR-KENNZIFF sy-vline
WA_EPROFILE_INTF_STR-ROLETYPE sy-vline
WA_EPROFILE_INTF_STR-PROFROLE sy-vline
WA_EPROFILE_INTF_STR-SRCSYSTEM sy-vline
WA_EPROFILE_INTF_STR-SRCADDR sy-vline
WA_EPROFILE_INTF_STR-EXTREFERENCE sy-vline
WA_EPROFILE_INTF_STR-EXTLOGNUMBER sy-vline
WA_EPROFILE_INTF_STR-PROFVAL sy-vline
WA_EPROFILE_INTF_STR-PROFSTAT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.