Below is a number of ABAP code snippets to demonstrate how to select data from SAP ESH_TAU_CL_P table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to ESH_TAU_CL_P. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the ESH_TAU_CL_P table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_ESH_TAU_CL_P TYPE STANDARD TABLE OF ESH_TAU_CL_P, WA_ESH_TAU_CL_P TYPE ESH_TAU_CL_P, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <ESH_TAU_CL_P> TYPE ESH_TAU_CL_P. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_ESH_TAU_CL_P. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM ESH_TAU_CL_P INTO TABLE IT_ESH_TAU_CL_P. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM ESH_TAU_CL_P * INTO TABLE @DATA(IT_ESH_TAU_CL_P2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_ESH_TAU_CL_P INDEX 1 INTO DATA(WA_ESH_TAU_CL_P2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_ESH_TAU_CL_P ASSIGNING <ESH_TAU_CL_P>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<ESH_TAU_CL_P>-MANDT = 1.
<ESH_TAU_CL_P>-PROPERTY_UUID = 1.
<ESH_TAU_CL_P>-VERSION_ID = 1.
<ESH_TAU_CL_P>-CHANGE_ORDER_ID = 1.
<ESH_TAU_CL_P>-VALID_FROM = 1.
ENDLOOP. LOOP AT IT_ESH_TAU_CL_P INTO WA_ESH_TAU_CL_P. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_ESH_TAU_CL_P-VALID_TO, sy-vline,
WA_ESH_TAU_CL_P-PARAM_EFFECT, sy-vline,
WA_ESH_TAU_CL_P-PROPERTY_ID, sy-vline,
WA_ESH_TAU_CL_P-DATA_TYPE_UUID, sy-vline,
WA_ESH_TAU_CL_P-LIFE_CYCLE_ST_CD, sy-vline,
WA_ESH_TAU_CL_P-PROPERTY_GROUP, sy-vline.
ENDLOOP. *Add any further fields from structure WA_ESH_TAU_CL_P you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_ESH_TAU_CL_P TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_ESH_TAU_CL_P INTO WA_ESH_TAU_CL_P. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_ESH_TAU_CL_P_STR,
MANDT TYPE STRING,
PROPERTY_UUID TYPE STRING,
VERSION_ID TYPE STRING,
CHANGE_ORDER_ID TYPE STRING,
VALID_FROM TYPE STRING,
VALID_TO TYPE STRING,
PARAM_EFFECT TYPE STRING,
PROPERTY_ID TYPE STRING,
DATA_TYPE_UUID TYPE STRING,
LIFE_CYCLE_ST_CD TYPE STRING,
PROPERTY_GROUP TYPE STRING,
ENTRY_REQUIRED TYPE STRING,
IS_SINGLE_VALUE TYPE STRING,
IS_MULTILIN TYPE STRING,
HAS_MULTILIN_VAL TYPE STRING,
INTV_VAL_ALLOWED TYPE STRING,
ADD_VAL_ALLOWED TYPE STRING,
DO_NOT_DISPLAY TYPE STRING,
NO_ENTRY TYPE STRING,
CREATED_BY TYPE STRING,
CREATED_AT TYPE STRING,
LAST_CHANGED_BY TYPE STRING,
LAST_CHANGED_AT TYPE STRING,END OF T_EKKO_STR. DATA: WA_ESH_TAU_CL_P_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_ESH_TAU_CL_P_STR-MANDT sy-vline
WA_ESH_TAU_CL_P_STR-PROPERTY_UUID sy-vline
WA_ESH_TAU_CL_P_STR-VERSION_ID sy-vline
WA_ESH_TAU_CL_P_STR-CHANGE_ORDER_ID sy-vline
WA_ESH_TAU_CL_P_STR-VALID_FROM sy-vline
WA_ESH_TAU_CL_P_STR-VALID_TO sy-vline
WA_ESH_TAU_CL_P_STR-PARAM_EFFECT sy-vline
WA_ESH_TAU_CL_P_STR-PROPERTY_ID sy-vline
WA_ESH_TAU_CL_P_STR-DATA_TYPE_UUID sy-vline
WA_ESH_TAU_CL_P_STR-LIFE_CYCLE_ST_CD sy-vline
WA_ESH_TAU_CL_P_STR-PROPERTY_GROUP sy-vline
WA_ESH_TAU_CL_P_STR-ENTRY_REQUIRED sy-vline
WA_ESH_TAU_CL_P_STR-IS_SINGLE_VALUE sy-vline
WA_ESH_TAU_CL_P_STR-IS_MULTILIN sy-vline
WA_ESH_TAU_CL_P_STR-HAS_MULTILIN_VAL sy-vline
WA_ESH_TAU_CL_P_STR-INTV_VAL_ALLOWED sy-vline
WA_ESH_TAU_CL_P_STR-ADD_VAL_ALLOWED sy-vline
WA_ESH_TAU_CL_P_STR-DO_NOT_DISPLAY sy-vline
WA_ESH_TAU_CL_P_STR-NO_ENTRY sy-vline
WA_ESH_TAU_CL_P_STR-CREATED_BY sy-vline
WA_ESH_TAU_CL_P_STR-CREATED_AT sy-vline
WA_ESH_TAU_CL_P_STR-LAST_CHANGED_BY sy-vline
WA_ESH_TAU_CL_P_STR-LAST_CHANGED_AT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.