ABAP Select data from SAP table EVPTD into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP EVPTD table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to EVPTD. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the EVPTD table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_EVPTD TYPE STANDARD TABLE OF EVPTD, WA_EVPTD TYPE EVPTD, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <EVPTD> TYPE EVPTD. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_EVPTD. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM EVPTD INTO TABLE IT_EVPTD. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM EVPTD * INTO TABLE @DATA(IT_EVPTD2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_EVPTD INDEX 1 INTO DATA(WA_EVPTD2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_EVPTD ASSIGNING <EVPTD>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<EVPTD>-MLST_ZAEHL = 1.
<EVPTD>-MLSTN = 1.
<EVPTD>-USERH = 1.
<EVPTD>-DATEH = 1.
<EVPTD>-USERV = 1.
ENDLOOP. LOOP AT IT_EVPTD INTO WA_EVPTD. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_EVPTD-DATEV, sy-vline,
WA_EVPTD-KZ_WFLOW, sy-vline,
WA_EVPTD-KZ_FRMST, sy-vline,
WA_EVPTD-KTEXT, sy-vline,
WA_EVPTD-USAGT, sy-vline,
WA_EVPTD-STDNR_ICSN, sy-vline.
ENDLOOP. *Add any further fields from structure WA_EVPTD you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_EVPTD TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_EVPTD INTO WA_EVPTD. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ALPHA, internal->external for field STDNR_ICSN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EVPTD-STDNR_ICSN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EVPTD-STDNR_ICSN.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field ALTNR_ICSN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EVPTD-ALTNR_ICSN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EVPTD-ALTNR_ICSN.
WRITE:/ 'New Value:', ld_input.
*Conversion exit NUMCV, internal->external for field OPRST_ICSN CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_EVPTD-OPRST_ICSN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EVPTD-OPRST_ICSN.
WRITE:/ 'New Value:', ld_input.
*Conversion exit NUMCV, internal->external for field OPREN_ICSN CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_EVPTD-OPREN_ICSN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EVPTD-OPREN_ICSN.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field STDNR_ICNW CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EVPTD-STDNR_ICNW IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EVPTD-STDNR_ICNW.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field ALTNR_ICNW CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EVPTD-ALTNR_ICNW IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EVPTD-ALTNR_ICNW.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_EVPTD_STR,
MLST_ZAEHL TYPE STRING,
MLSTN TYPE STRING,
USERH TYPE STRING,
DATEH TYPE STRING,
USERV TYPE STRING,
DATEV TYPE STRING,
KZ_WFLOW TYPE STRING,
KZ_FRMST TYPE STRING,
KTEXT TYPE STRING,
USAGT TYPE STRING,
STDNR_ICSN TYPE STRING,
ALTNR_ICSN TYPE STRING,
OPRST_ICSN TYPE STRING,
OPREN_ICSN TYPE STRING,
AUART_ICNW TYPE STRING,
STDNR_ICNW TYPE STRING,
ALTNR_ICNW TYPE STRING,END OF T_EKKO_STR. DATA: WA_EVPTD_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_EVPTD_STR-MLST_ZAEHL sy-vline
WA_EVPTD_STR-MLSTN sy-vline
WA_EVPTD_STR-USERH sy-vline
WA_EVPTD_STR-DATEH sy-vline
WA_EVPTD_STR-USERV sy-vline
WA_EVPTD_STR-DATEV sy-vline
WA_EVPTD_STR-KZ_WFLOW sy-vline
WA_EVPTD_STR-KZ_FRMST sy-vline
WA_EVPTD_STR-KTEXT sy-vline
WA_EVPTD_STR-USAGT sy-vline
WA_EVPTD_STR-STDNR_ICSN sy-vline
WA_EVPTD_STR-ALTNR_ICSN sy-vline
WA_EVPTD_STR-OPRST_ICSN sy-vline
WA_EVPTD_STR-OPREN_ICSN sy-vline
WA_EVPTD_STR-AUART_ICNW sy-vline
WA_EVPTD_STR-STDNR_ICNW sy-vline
WA_EVPTD_STR-ALTNR_ICNW sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.