ABAP Select data from SAP table EWA_EHS_DATA into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP EWA_EHS_DATA table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to EWA_EHS_DATA. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the EWA_EHS_DATA table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_EWA_EHS_DATA TYPE STANDARD TABLE OF EWA_EHS_DATA, WA_EWA_EHS_DATA TYPE EWA_EHS_DATA, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <EWA_EHS_DATA> TYPE EWA_EHS_DATA. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_EWA_EHS_DATA. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM EWA_EHS_DATA INTO TABLE IT_EWA_EHS_DATA. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM EWA_EHS_DATA * INTO TABLE @DATA(IT_EWA_EHS_DATA2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_EWA_EHS_DATA INDEX 1 INTO DATA(WA_EWA_EHS_DATA2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_EWA_EHS_DATA ASSIGNING <EWA_EHS_DATA>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<EWA_EHS_DATA>-EHS_PARTNER = 1.
<EWA_EHS_DATA>-INTAPPNO = 1.
<EWA_EHS_DATA>-APPNO = 1.
<EWA_EHS_DATA>-RECN = 1.
<EWA_EHS_DATA>-WAKEYIDE = 1.
ENDLOOP. LOOP AT IT_EWA_EHS_DATA INTO WA_EWA_EHS_DATA. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_EWA_EHS_DATA-WAKEYCATLG, sy-vline,
WA_EWA_EHS_DATA-MNAMIN, sy-vline,
WA_EWA_EHS_DATA-MNAMQIN, sy-vline,
WA_EWA_EHS_DATA-MNINO_UNS, sy-vline,
WA_EWA_EHS_DATA-MNINO_BGS, sy-vline,
WA_EWA_EHS_DATA-TRANSPORTER, sy-vline.
ENDLOOP. *Add any further fields from structure WA_EWA_EHS_DATA you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_EWA_EHS_DATA TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_EWA_EHS_DATA INTO WA_EWA_EHS_DATA. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ALPHA, internal->external for field EHS_PARTNER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EWA_EHS_DATA-EHS_PARTNER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EWA_EHS_DATA-EHS_PARTNER.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field INTAPPNO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EWA_EHS_DATA-INTAPPNO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EWA_EHS_DATA-INTAPPNO.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field APPNO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EWA_EHS_DATA-APPNO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EWA_EHS_DATA-APPNO.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field MNAMQIN CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_EWA_EHS_DATA-MNAMQIN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EWA_EHS_DATA-MNAMQIN.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field TRANSPORTER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EWA_EHS_DATA-TRANSPORTER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EWA_EHS_DATA-TRANSPORTER.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field DISPOSER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EWA_EHS_DATA-DISPOSER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EWA_EHS_DATA-DISPOSER.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field RECNWAKEY CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EWA_EHS_DATA-RECNWAKEY IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EWA_EHS_DATA-RECNWAKEY.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_EWA_EHS_DATA_STR,
EHS_PARTNER TYPE STRING,
INTAPPNO TYPE STRING,
APPNO TYPE STRING,
RECN TYPE STRING,
WAKEYIDE TYPE STRING,
WAKEYCATLG TYPE STRING,
MNAMIN TYPE STRING,
MNAMQIN TYPE STRING,
MNINO_UNS TYPE STRING,
MNINO_BGS TYPE STRING,
TRANSPORTER TYPE STRING,
DISPOSER TYPE STRING,
RECNWAKEY TYPE STRING,
E_WERKS TYPE STRING,
E_LGORT TYPE STRING,END OF T_EKKO_STR. DATA: WA_EWA_EHS_DATA_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_EWA_EHS_DATA_STR-EHS_PARTNER sy-vline
WA_EWA_EHS_DATA_STR-INTAPPNO sy-vline
WA_EWA_EHS_DATA_STR-APPNO sy-vline
WA_EWA_EHS_DATA_STR-RECN sy-vline
WA_EWA_EHS_DATA_STR-WAKEYIDE sy-vline
WA_EWA_EHS_DATA_STR-WAKEYCATLG sy-vline
WA_EWA_EHS_DATA_STR-MNAMIN sy-vline
WA_EWA_EHS_DATA_STR-MNAMQIN sy-vline
WA_EWA_EHS_DATA_STR-MNINO_UNS sy-vline
WA_EWA_EHS_DATA_STR-MNINO_BGS sy-vline
WA_EWA_EHS_DATA_STR-TRANSPORTER sy-vline
WA_EWA_EHS_DATA_STR-DISPOSER sy-vline
WA_EWA_EHS_DATA_STR-RECNWAKEY sy-vline
WA_EWA_EHS_DATA_STR-E_WERKS sy-vline
WA_EWA_EHS_DATA_STR-E_LGORT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.